efm-0122 Astrodyne Corporation, efm-0122 Datasheet - Page 2

no-image

efm-0122

Manufacturer Part Number
efm-0122
Description
10w Ultraminiature Open Frame Switching Power Supplies
Manufacturer
Astrodyne Corporation
Datasheet
All specifications are typical at nominal input, full load, and 25°C unless other-
wise noted
INPUT SPECIFICATIONS
Input Voltage Range
Frequency Range
Inrush Current (115/230Vin)
OUTPUT SPECIFICATIONS
Voltage and Current (Note 5)
Load Regulation (20%-FL)(Note 6) Singles: ± 3%,
Line Regulation, typ (Note 7)
Cross Regulation (Note 10)
Preset Accuracy (Note 8)
DC Voltage Adjust (typ)
Temperature Coefficient
Ripple/Noise, typ (Note 1, 9)
Over Voltage Protection
Over Temp. Protection
Short Circuit Protection (Note 2) Continuous, self-recovering
Hold Up Time
DC Output Power
PHYSICAL SPECIFICATIONS
Size
Construction
Weight
*
may adversely affect long term reliability. Proper operation under conditions
other than the standard operating conditions is neither warranteed nor implied.
1 0 W U lt r aminiat ur e O p en Fr a me Swit ch i ng P ower Suppl ies
WWW.ASTRODYNE.COM
These are stress ratings. Exposure of the devices to any of these conditions
90-264 VAC
47-63 Hz
20/40Amps, typ.
See Selection Chart
Duals: ± 3% (EFM-0108: 0.5/3%)
Triple: 0.2 / ±0.3%
Singles ± 0.1~1%
Duals ± 0.3~1%
(except EFM-0108: 0.5/ 0.5%)
Triple: 0.3 / ±0.1%
Duals 2% (EFM-0108: 0.5/3%)
Triple: NA/ ±0.1%
Single/Duals 1%
(except EFM-0108: 2 / 5%)
Triple: 1 / ±5%
± 6% of FS (Primary)
±0.03%/°C
Single/Dual: 100mVpk-pk (except
EFM-0108: 50/50mVpk-pk)
Triple: 50 / ±75mVpk-pk
Clamp
Latching, recov after cooling and
power restored
30 mS, typ
10 Watts, max
1.66” x 2.46” x 0.91”
Open Frame
1.6oz (44g)
GENERAL SPECIFICATIONS
Isolation (Note 3)
Efficiency
Switching Frequency
Safety
EMC
ENVIRONMENTAL SPECIFICATIONS
Oper. Temperature (Note 4)
Storage Temperature
Relative Humidity
MTBF
NOTES
1. Ripple and Noise depend upon output voltage as specified per par-
ticular model.
2. Short Curcuit Protection is self-recovering when overcurrent condition
is removed.
3.Isolation for up to 1 minute duration.
4. Specified for free-air convection cooling.
5. Minimum load is NOT required for proper operation. However, auxil-
iary outputs should be reduced as a function of primary output minimum
load or load regulation will be higher.
6. Load regulation measured from 20% to full load.
7. Line regulation measured from 90VAC to 264VAC.
8. Preset accuracy measured at nominal load, 120VAC input.
9. O/P noise measured directly at pins/terminals at nom. load, 0.1uF
bypass, pk-pk @20MHz bandwidth.
10.Cross Reg-Duals: Measured at nom. load with the other output varied
between 60% and 100% inom.
Astrodyne products are not authorized or warranteed for use
as critical components in life support systems, equipment used
in hazardous environments, nuclear controls systems, or other
mission-critical applications.
ASTRODYNE USA: 1-800-823-8082
ASTRODYNE PACIFIC: 886-2-26983458
3KVAC Input-Output
2500VAC Inpout-Ground
1000VAC Output-Ground
Single/Dual 75% typ
Triple 70%
100Khz, (fixed, typical)
UL60950-1, EN60950-1
EN55022
-0 to +40°C (See Derate)
-25 to +71°C
0 to + 95%, non-cond
(Mil Std 217, 25°C)
E F M 1 0
*
*
575,000 Hrs
s e r i e s

Related parts for efm-0122