THERMAL CONSIDERATIONS
Thermal management is an important part of the system
design. To ensure proper, reliable operation, sufficient
cooling of the power module is needed over the entire
temperature range of the module. Convection cooling is
usually the dominant mode of heat transfer.
Hence, the choice of equipment to characterize the
thermal performance of the power module is a wind
tunnel.
Thermal Testing Setup
Delta’s DC/DC power modules are characterized in
heated wind
environments
equipment.
The
characterization setup. The power module is mounted
on Primarion test board and is horizontally positioned
within the wind tunnel.
Figure 46: Wind Tunnel Test Setup (Parallel Module)
Longitudinal Orientation:
Transverse Orientation:
following
Side View
Top View
Side View
Top View
tunnels that
encountered
figures
show
Airflow
Airflow
simulate
in
Airflow
Airflow
the
most
wind
the
electronics
Front View
thermal
Front View
tunnel
Thermal De-rating
The module’s maximum hot spot temperature is 105°C.
To enhance system reliability, the power module should
always be operated below the maximum operating
temperature. If the temperature exceeds the maximum
module temperature, reliability of the unit may be
affected.
Figure 47: Temperature measurement location
The allowed maximum hot spot temperature is defined at 105