S10810-11 Hamamatsu Photonics, K.K.,, S10810-11 Datasheet - Page 3

no-image

S10810-11

Manufacturer Part Number
S10810-11
Description
Ccd Area Image Sensors
Manufacturer
Hamamatsu Photonics, K.K.,
Datasheet
*5: V
*6: Dark signal doubles for every 5 to 7 °C.
*7: -40 °C, operating frequency is 1 MHz.
*8: Dynamic range = Full well capacity / Readout noise
*9: X-ray irradiation of 60 kVp, measured at half of the full well capacity
*10: XRNU (%) = Noise / Signal × 100
*11: Refer to “Characteristics and use of FFT-CCD area image sensor” of technical information.
*12: White spots > 10 times of Max. Dark signal (2500 e
*13: Continuous 2 to 9 point defects
*14: Continuous ≥ 10 point defects
Full well capacity
CCD node sensitivity*
Dark current (MPP mode)*
Readout noise*
Dynamic range*
X-ray response non-uniformity*
Blemish*
X-ray resolution*
Resolution (S10810-11)
Electrical and optical characteristics (Ta=25 °C, V
OD
Noise: Fixed pattern noise (peak to peak)
In the range that excludes 5 pixels from edges to the center at every position
Black spots > 50% reduction in response relative to adjacent pixels, measured at half of the full well capacity
1.0
0.9
0.8
0.7
0.6
0.5
0.4
0.3
0.2
0.1
=15 V, R
0
11
0
2
7
Point
defects*
Cluster defects*
Column defects*
L
8
9
Parameter
Spatial frequency (line pairs/mm)
(load resistance of emitter follower)=1 kΩ
CCD area image sensors
(X-ray source: 70 kVp, Filter: ABS 1.5 mm
4
5
12
6
6
8
Vertical
Horizontal
Summing
White spots
Black spots
13
9
14
*
10
10
12
14
16
Symbol
XRNU
Fw
DS
DR
∆R
Sv
Nr
18
-
KMPDB0355EA
-
/pixel/s)
t
20
)
OD
Min.
100
1.0
15
Response (S10810-11)
=15 V, unless otherwise noted)
-
-
-
-
-
-
-
-
-
-
S8980, S10810-11
300
200
100
0
0
(X-ray source: 70 kVp, Filter: ABS 1.5 mm
3333
Typ.
±10
200
300
600
250
1.4
60
20
-
-
-
-
Absorbed dose (µGy)
100
Max.
2500
±30
20
20
200
3
1
-
-
-
-
-
-
-
e
Lp/mm
-
e
KMPDB0356EA
/pixel/s
μV/e
Unit
-
ke
%
300
rms
t
-
-
)
-
-
3

Related parts for S10810-11