cs10.481 B&B Electronics Mfg, cs10.481 Datasheet
cs10.481
Related parts for cs10.481
cs10.481 Summary of contents
Page 1
... ZM1.WALL Wall mount bracket ZM13.SIDE Side mount bracket YRM2.DIODE Redundancy module Nov. 2006 / Rev.1.1 DS-CS10.481-EN All parameters are specified at 48V, 5A, 230Vac, 25°C ambient and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com Phone +49 89 9278 0 P OWER ■ AC 100-120 / 200-240V Auto Select Input ■ ...
Page 2
... ISCLAIMER The information presented in this document is believed to be accurate and reliable and may change without notice. Nov. 2006 / Rev.1.1 DS-CS10.481-EN All parameters are specified at 48V, 5A, 230Vac, 25°C ambient and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com Phone +49 89 9278 0 ...
Page 3
... Output Current Nov. 2006 / Rev.1.1 DS-CS10.481-EN All parameters are specified at 48V, 5A, 230Vac, 25°C ambient and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com Phone +49 89 9278 0 nom. AC 100-120V / auto-select input, TN-, TT-, IT-Mains, see 200-240V 90-132Vac 100-120V range, continuous operation ...
Page 4
... Note load, the hold-up time can several seconds. The green DC-ok lamp is on during this time. Nov. 2006 / Rev.1.1 DS-CS10.481-EN All parameters are specified at 48V, 5A, 230Vac, 25°C ambient and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com Phone +49 89 9278 0 ...
Page 5
... Detailed curves can be found in chapter 25.1. Peak current voltage dips Nov. 2006 / Rev.1.1 DS-CS10.481-EN All parameters are specified at 48V, 5A, 230Vac, 25°C ambient and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com Phone +49 89 9278 0 nom ...
Page 6
... Fig. 9-3 Efficiency vs. input voltage, 48V, 5A Efficiency 92 Input Voltage 88 85 120 155 190 Nov. 2006 / Rev.1.1 DS-CS10.481-EN All parameters are specified at 48V, 5A, 230Vac, 25°C ambient and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com Phone +49 89 9278 0 L OSSES AC 100V AC 120V typ. 90.7% 91.0% typ. 5.8W 8 ...
Page 7
... It is the statistical representation of the likelihood of a unit to fail and does not necessarily represent the life of a product. Nov. 2006 / Rev.1.1 DS-CS10.481-EN All parameters are specified at 48V, 5A, 230Vac, 25°C ambient and after a 5 minutes run-in time unless otherwise noted. ...
Page 8
... Up to two stranded wires with the same cross section are permitted in one connection point (except PE wire not use the unit without PE connection. Nov. 2006 / Rev.1.1 DS-CS10.481-EN All parameters are specified at 48V, 5A, 230Vac, 25°C ambient and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com Phone +49 89 9278 0 ...
Page 9
... C: Temporary loss of function is possible. Power supply might shut-down and restarts by itself. No damages or hazards for the power supply occur. Switching frequency 85kHz to 110kHz Nov. 2006 / Rev.1.1 DS-CS10.481-EN All parameters are specified at 48V, 5A, 230Vac, 25°C ambient and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com Phone +49 89 9278 0 48V, 5A, S ...
Page 10
... This is recommended for devices used in professional applications with an input power greater than 1000W. Nov. 2006 / Rev.1.1 DS-CS10.481-EN All parameters are specified at 48V, 5A, 230Vac, 25°C ambient and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com Phone +49 89 9278 0 CS10 ...
Page 11
... Input transient protection Internal input fuse Note: In case of a protection event, audible noise may occur. Nov. 2006 / Rev.1.1 DS-CS10.481-EN All parameters are specified at 48V, 5A, 230Vac, 25°C ambient and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com Phone +49 89 9278 0 -25°C to +70°C (-13°F to 158°F) 3.2W/° ...
Page 12
... This helps to avoid situations in which a load starts unexpectedly or can not be switched off any more when unnoticed earth faults occur. Nov. 2006 / Rev.1.1 DS-CS10.481-EN All parameters are specified at 48V, 5A, 230Vac, 25°C ambient and after a 5 minutes run-in time unless otherwise noted. ...
Page 13
... Polybrom Biphenyl (PBB), Polybrom Bipheny-oxyd (PBO), Polybrominated Diphenylether (PBDE), Polychlorinated Diphenylether (PCDE), Polydibromphenyl Oxyd (PBDO), Cadmium, Asbest, Mercury, Silicia Nov. 2006 / Rev.1.1 DS-CS10.481-EN All parameters are specified at 48V, 5A, 230Vac, 25°C ambient and after a 5 minutes run-in time unless otherwise noted. ...
Page 14
... The unit does not contain any service parts. The tripping of an internal fuse is caused by an internal defect. If damage or malfunctioning should occur during operation, immediately turn power off and send unit to factory for inspection! Nov. 2006 / Rev.1.1 DS-CS10.481-EN All parameters are specified at 48V, 5A, 230Vac, 25°C ambient and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com Phone +49 89 9278 0 ...
Page 15
... For sideway DIN-rail mounting, the removed aluminum brackets and the black plastic slider need to be mounted on the steel bracket. Fig. 24-3 ZM13.SIDE Side Mounting Bracket Nov. 2006 / Rev.1.1 DS-CS10.481-EN All parameters are specified at 48V, 5A, 230Vac, 25°C ambient and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com Phone +49 89 9278 0 CS10 ...
Page 16
... HARGING OF ATTERIES The power supply shall not be used to charge batteries. Choose Q-Series for charging batteries. Nov. 2006 / Rev.1.1 DS-CS10.481-EN All parameters are specified at 48V, 5A, 230Vac, 25°C ambient and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com Phone +49 89 9278 0 48V, 5A, S INGLE Fig ...
Page 17
... Nov. 2006 / Rev.1.1 DS-CS10.481-EN All parameters are specified at 48V, 5A, 230Vac, 25°C ambient and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com Phone +49 89 9278 0 Parameters: Input voltage: ...
Page 18
... YRM2.DIODE. This feature reports a faulty unit. c) When possible, connect each power supply to different phases or circuits. Nov. 2006 / Rev.1.1 DS-CS10.481-EN All parameters are specified at 48V, 5A, 230Vac, 25°C ambient and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com Phone +49 89 9278 0 ...
Page 19
... Temperature outside the box: 23.3°C Temperature rise: 25.6K Nov. 2006 / Rev.1.1 DS-CS10.481-EN All parameters are specified at 48V, 5A, 230Vac, 25°C ambient and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com Phone +49 89 9278 0 C-Characteristic 20A ...
Page 20
... Fig. 25-10 Mounting Orientation D (Horizontal cw) Fig. 25-11 Mounting Orientation E (Horizontal ccw) Nov. 2006 / Rev.1.1 DS-CS10.481-EN All parameters are specified at 48V, 5A, 230Vac, 25°C ambient and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com Phone +49 89 9278 0 Output Current 6A 4.5 3 1.5 Ambient Temperature 0 ...