lt100-24 Megastar Electronics Inc., lt100-24 Datasheet

no-image

lt100-24

Manufacturer Part Number
lt100-24
Description
Lt Series Axial Leaded Ptc
Manufacturer
Megastar Electronics Inc.
Datasheet
Electrical Characteristics (23°C)
IH=Hold current-maximum current at which the device will not trip at 23°C still air.
IT=Trip current-minimum current at which the device will always trip at 23°C still air.
V MAX=Maximum voltage device can withstand without damage at its rated current.
I MAX= Maximum fault current device can withstand without damage at rated voltage (V max).
Pd=Typical power dissipated from device when in the tripped state in 23°C still air environment.
RMIN=Minimum device resistance at 23°C.
R1MAX=Maximum device resistance at 23°C, 1 hour after tripping .
Lead material:0.13mm.nominal thickness ,quarter-hard nickel.
Insulating material: Polyester tape.
Part
Number
LT070-24
LT100-24
LT180-24
LT190-24
LT260-24
LT300-24
LT310-24
LT340-24
Current
Hold
IH, A
0.7
1.0
1.8
1.9
2.6
3.0
3.1
3.4
Current
IT, A
Trip
1.5
2.5
3.8
4.2
5.2
6.3
6.0
6.8
Application:
Product Features:
Operation Current:
Maximum Voltage:
Temperature Range:
Agency Recognition:
VMAX, Vdc
Voltage
Rated
24
24
24
24
24
24
24
24
Maximum
IMAX, A
Current
100
100
100
100
100
100
100
100
Rechargeable battery packs
Lithium cell and battery packs
Low profile, Solid stat
0.7A~3.4 A
24V
-40°C to 85°C
UL, C-UL, TÜV
Typical
Power
Pd, W
1.1
1.5
2.0
1.9
2.3
2.0
2.5
2.7
Specifications are subject to change without notice.
RMIN
0.100
0.070
0.040
0.030
0.025
0.015
0.018
0.016
ohms
Resistance Tolerance
Axial Leaded PTC
RMAX
ohms
0.200
0.130
0.068
0.057
0.042
0.031
0.030
0.027
LEAD FREE
RoSH COMPLIANT
R1MAX
Pb
0.340
0.260
0.120
0.100
0.076
0.055
0.055
0.050
ohms
b

Related parts for lt100-24

lt100-24 Summary of contents

Page 1

... Electrical Characteristics (23°C) Part Hold Number Current IH, A LT070-24 0.7 LT100-24 1.0 LT180-24 1.8 LT190-24 1.9 LT260-24 2.6 LT300-24 3.0 LT310-24 3.1 LT340-24 3.4 IH=Hold current-maximum current at which the device will not trip at 23°C still air. IT=Trip current-minimum current at which the device will always trip at 23°C still air. ...

Page 2

... LT Product Dimensions (Millimeters) Part A Number Min LT070-24 19.9 LT070-24S 19.9 LT100-24 20.9 LT100-24S 20.9 LT180-24 24.0 LT180-24S 24.0 LT190-24 21.3 LT260-24 24.0 LT300-24 28.4 LT310-24 24.0 LT340-24 24.0 Thermal Derating Curve B Max Min Max Min 22.1 4.9 5.2 0.7 22.1 4.9 5.2 0.7 23.1 4.9 5.2 0.6 23.1 4.9 5.2 0.6 26.0 4.9 5.2 0.6 26.0 4.9 5.2 0.6 23.4 10.2 11.0 0.5 26.0 10.8 11.9 0.6 31.8 13.0 13.5 0.5 26.0 14.8 15.9 0.6 26.0 14.8 15.9 0.6 Axial Leaded PTC C D Max Min Max 1.2 5.5 7.5 1.2 5.5 7.5 1.0 4.1 5.5 1.0 4.1 5.5 1.0 4.1 5.5 1.0 4.1 5.5 1.1 5.0 7.6 1.0 5.0 7.0 1.1 6.3 8.9 1.0 5.0 7.0 1.0 4.0 5.0 Specifications are subject to change without notice. F Min Max 3.9 4.1 3.9 4.1 3.9 4.1 3.9 4.1 3.9 4.1 3.9 4.1 4.8 5.4 5.9 6.1 6.0 6.6 5.9 6.1 5.9 6.1 ...

Page 3

... H=LT340-24 Part Numbering System Nil : Bulk T : Tape & Reel Nil : S : Slitted Lead Voltage Rating Current Rating Standard Package P/N Pcs /Bag LT070-24 1K LT100-24 1K LT180-24 1K LT190-24 500 LT260-24 500 LT300-24 500 LT310-24 500 LT340-24 500 1- Operation beyond the specified maximum ratings or improper use may result in damage and possible electrical arcing and/or fl ...

Related keywords