tr100a190 RSG Electronic Components GmbH, tr100a190 Datasheet

no-image

tr100a190

Manufacturer Part Number
tr100a190
Description
100w Switching Adapter With Pfc
Manufacturer
RSG Electronic Components GmbH
Datasheet
159
ELECTRONIC COMPONENTS
RSG
• Universal Input: 90 ~ 264Vac
• Conductive EMI Meets CISPR/FCC Class B
• High Efficiency, 85% Typical
Specifications
Features
Typical at 25˚C, nominal line and 75% load, unless otherwise Specified
TR100
INPUT CHARACTERISTICS:
Voltage ...............................................................90 ~ 264Vac
Frequency ..............................................................47 to 63Hz
Inrush Current .................................... 100A Max. @ 264Vac
Conducted EMI ......................................CISPR/FCC Class B
Isolation ..................................... Input to output =4,242Vdc
Leakage Current.................................................3.5mA max.
ENVIRONMENTAL CHARACTERISTICS:
Operating Temperature ......................................... 0 ~ 40˚C
Storage Temperature
TR100
CB
100W SWITCHING ADAPTER
WITH PFC
RSG Electronic Components GmbH
Tel. +49 69 984047-0
Änderungen vorbehalten / subject to change without notice
S
................................................
E
Fax +49 69 984047-77
R
-20 ~ 85˚C
Sprendlinger Landstr. 115
I
info@rsg-electronic.de
OUTPUT CHARACTERISTICS:
Holdup Time
Short Circuit Protection
Over Voltage Protection
MECHANICAL CHARACTERISTICS:
Dimensions
Weight
PS
E
E
.........................................................................................600g
..........150 x 70 x 35mm (
..............................................
S
D-63069 Offenbach/Germany
...........................................
www.rsg-electronic.de
..................................... Auto Recovery
5.91 x 2.76 x 1.38 Inches)
20mS typ. @ 115Vac
Continuous
NOTE:
1. Voltage accuracy is set at 60% full load.
2. Add a 0.1µF ceramic capacitor and a 10µF E.L. capacitor to output for Ripple & Noise measurement @20MHz BW.
3. Line regulation is measured from 100Vac to 240Vac, full load.
4. Load regulation is measured from 60% to 100% full load and from 60% to 20% full load (60% +/- 40% full load)
5. Cable Length Iimit for TR100A120/150:1200mm(max.)
TR100A120
TR100A150
TR100A180
TR100A190
TR100A240
TR100A280
TR100A290
TR100A300
TR100A360
TR100A480
Cable Length Iimit for TR100A180/190/240/480:1800mm(max.)
(For Customer Design)
MODEL
UNIT: mm(Inches)
Mechanical Specification
VOLTAGE
OUTPUT
12 V
15 V
18 V
19 V
24 V
28 V
29 V
30 V
36 V
48 V
8.33 A
6.67 A
5.56 A
5.21 A
4.17 A
3.54 A
3.41 A
3.30 A
2.78 A
2.08 A
LOAD
MAX.
LOAD
MIN.
0 A
0 A
0 A
0 A
0 A
0 A
0 A
0 A
0 A
0 A
(5.91)
150
RIPPLE &
NOISE
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
LED
ACCURACY
VOLTAGE
± 2%
± 2%
± 2%
± 2%
± 2%
± 2%
± 2%
± 2%
± 2%
± 2%
REGULATION
Cable Iength (NOTE 5)
LINE
± 1%
± 1%
± 1%
± 1%
± 1%
± 1%
± 1%
± 1%
± 1%
± 1%
REGULATION
LOAD
± 4%
± 4%
± 2%
± 2%
± 2%
± 2%
± 2%
± 2%
± 2%
± 2%
-
+
160

Related parts for tr100a190

Related keywords