tem15-t0515 Tumbler Technologies + TRUMPower, tem15-t0515 Datasheet - Page 2

no-image

tem15-t0515

Manufacturer Part Number
tem15-t0515
Description
15 Watts Ac/dc Medical Power Modules
Manufacturer
Tumbler Technologies + TRUMPower
Datasheet
INPUT SPECIFICATIONS
Input Voltage Range ................... 90~264 VAC or 100~375 VDC
Input Frequency .......................... 47~440Hz
Input Current. .............................. 220mA max. @ 115 VAC
Inrush Current . ........................... 10A max. @ 115 VAC
Leakage Current ........................ 0.1mA max. @ 115 VAC
Recommended External Fuse ... 2.0A slow blow type
OUTPUT SPECIFICATIONS
Output Wattage ........................... 15W max.
Output Voltage ............................ See tables
Voltage Accuracy, Single ............. ±2% max.
Minimum Load, Single ............... Not required
Line Regulation, Single ............. 0.5% max.
Ripple & Noise* .......................... 1% of Vout
Hold-up Time .............................. 20ms min.
Switching Frequency .................. 132KHz
Overcurrent Protection ............... Above 105% rated
Overvoltage Protection ............... Zener diode clamp
Short-circuit Protection ............... Hiccup mode, indefinite
Over Temperature Protection ..... 100 ° C
Input-Output Isolation ................ 4000 VAC
*Ripple & Noise are measured at 20MHz of bandwidth with 0.1µF & 47µF
capacitors in parallel.
MECHANICAL DRAWING
TEM15 Series
3350 Scott Blvd., Building 13 • Santa Clara, California 95054, USA • 408-988-6616 • sales@trumpower.com • www.TRUMPower.com
Dual ................. 10%
Triple ................ 25%
Dual ............... ±2% max.
Triple .............. ±3% max.
Dual ............... 0.5% max.
Triple .............. 2% max.
118mA max. @ 230 VAC
20A max. @ 230 VAC
0.2mA max. @ 230 VAC
output power
(automatic-recover)
Tumbler Technologies + TRUMPower
GENERAL SPECIFICATIONS
Efficiency ................................. 83% max.
Operating Temperature .......... -25 ° C to +70 ° C
Derating ................................... Derate linearly from 100%
Case Temperature .................. +95 ° C max.
Cooling .................................... Free-air convection
Storage Temperature .............. -40 ° C to +100 ° C
Temperature Coefficient ......... ±0.01%/ ° C
Relative Humidity .................... 95% RH
MTBF ........................................ 200K to 400K hours at full load,
Dimensions (LxWxH) ............ 2.52 x 1.79 x 0.92 inches
Case Material ............................ Plastic resin with fiberglass case,
Weight ...................................... 120g
EMC & SAFETY STANDARDS
Safety Standards ..................... UL 60601-1, IEC60601-1,
Safety Approvals ...................... UL, cUL, CB
EMI (PFI Conducted) ............... EN55011, Class B
EMC Standards ....................... EN60601-1-2
ESD Susceptibility .................. EN60601-1-2
Radiated Susceptibility ........... EN60601-1-2
EFT / Burst ............................... EN60601-1-2
Surge ....................................... EN60601-1-2
Conducted Susceptibility ........ EN60601-1-2
PIN CHART
P
I
N
2
3
4
5
6
7
8
9
1
All specifications typical at nominal input voltage, full load and +25 ° C
N
O
15 Watts AC/DC Medical Power Modules
.
+
A
-
A
S
D
N
N
N
D
N
N
C
C
I
C
N
O
O
O
O
O
C
after warm-up time unless otherwise noted.
N I
N I
G
O
P
P
P
O
P
P
L
N I
U
N I
N I
N I
N I
(
(
U
N
E
) L
T
T
)
C
+
A
-
A
D
N
N
D
N
N
O
D
C
C
C
O
O
C
O
O
M
U
N I
N I
O
M
A
P
P
O
P
P
@ 50 ° C to 50% @ 70 ° C
25 ° C ambient, calculated per
MIL-HDBK-217F
(64.0 x 45.6 x 23.5 mm)
UL 94V-0 rated
EN 60601-1
L
N I
U
N I
N I
N I
(
(
O
U
N
) L
T
N
T
)
C
+
A
A
+
-
+
T
D
N
N
D
5
O
5
C
C
R
C
O
V
V
O
C
M
P I
N I
N I
O
O
M
P
R
P
O
L
N I
T
U
U
N I
(
(
O
U
E
N
) L
N
T
T
T
N
)
TEM15-2011-0119-1

Related parts for tem15-t0515