TEACH-IN window mode, normally-open function
TEACH-IN window mode, normally-closed function
TEACH-IN switching point, normally-open function
TEACH-IN switching point, normally-closed function
TEACH-IN detection of objects presence
Default setting of switching points
Installation conditions
Five different output functions can be set
1. Window mode, normally-open function
2. Window mode, normally-closed function
3. one switching point, normally-open function
4. one switching point, normally-closed function
5. Detection of object presence
A1 = blind range, A2 = nominal distance
If the sensor is installed at places, where the environment temperature can fall below 0 °C, for the sensors fixation, one of the
mounting flanges BF 12, BF 12-F or BF 5-30 must be used. In case of direct mounting of the sensor in a through hole, it has to
be fixed at the middle of the housing thread.
Note
If the sensor is used in an environment with strong electromagnetic interference, we recommend non-conductive mounting. For this,
use the accompanying plastic nuts or the BF12 or BF12-F mounting flange.
Please observe proper application when using the accompanying plastic nuts. The hole for the sensor must be ≥ 14 mm.
Ultrasonic sensor
Set target to near switching point
TEACH-IN switching point A1 with -U
Set target to far switching point
TEACH-IN switching point A2 with +U
Set target to near switching point
TEACH-IN switching point A2 with +U
Set target to far switching point
TEACH-IN switching point A1 with -U
Set target to near switching point
TEACH-IN switching point A2 with +U
Cover sensor with hand or remove all objects from sensing range
TEACH-IN switching point A1 with -U
Set target to near switching point
TEACH-IN switching point A1 with -U
Cover sensor with hand or remove all objects from sensing range
TEACH-IN switching point A2 with +U
Cover sensor with hand or remove all objects from sensing range
TEACH-IN switching point A1 with -U
TEACH-IN switching point A2 with +U