IDT™ / ICS™ LOCO™ PLL CLOCK GENERATOR
ICS513
LOCO™ PLL CLOCK GENERATOR
External Components
Decoupling Capacitor
As with any high-performance mixed-signal IC, the
ICS513 must be isolated from system power supply
noise to perform optimally.
A decoupling capacitor of 0.01µF must be connected
between VDD and the GND. It must be connected close
to the ICS513 to minimize lead inductance. No external
power supply filtering is required for the ICS513.
Series Termination Resistor
A 33Ω terminating resistor can be used next to the CLK
and REF pins for trace lengths over one inch.
Crystal Load Capacitors
The total on-chip capacitance is approximately 12 pF. A
parallel resonant, fundamental mode crystal should be
used. The device crystal connections should include
pads for small capacitors from X1 to ground and from
Absolute Maximum Ratings
Stresses above the ratings listed below can cause permanent damage to the ICS513. These ratings, which
are standard values for ICS commercially rated parts, are stress ratings only. Functional operation of the
device at these or any other conditions above those indicated in the operational sections of the
specifications is not implied. Exposure to absolute maximum rating conditions for extended periods can
affect product reliability. Electrical parameters are guaranteed only over the recommended operating
temperature range.
Supply Voltage, VDD
All Inputs and Outputs (referenced to GND)
Ambient Operating Temperature
Storage Temperature
Soldering Temperature
Item
3
X2 to ground. These capacitors are used to adjust the
stray capacitance of the board to match the nominally
required crystal load capacitance. Because load
capacitance can only be increased in this trimming
process, it is important to keep stray capacitance to a
minimum by using very short PCB traces (and no vias)
between the crystal and device. Crystal capacitors, if
needed, must be connected from each of the pins X1
and X2 to ground.
The value (in pF) of these crystal caps should equal (C
-12 pF)*2. In this equation, C
in pF. Example: For a crystal with a 16 pF load
capacitance, each crystal capacitor would be 8 pF
[(16-12) x 2] = 8.
7 V
-0.5 V to VDD+0.5 V
0 to +70°C
-65 to +150°C
260°C
L
Rating
= crystal load capacitance
ICS513
CLOCK MULTIPLIER
REV D 070704
L

Related parts for ics513