SPECIFICATIONS
Contact
Coil
Remarks
* Specifications will vary with foreign standards certification ratings.
*
*
*
*
*
*
*
TYPICAL APPLICATIONS
1. Home appliances
2. Automotive
76
1
2
3
4
5
6
7
Arrangement
Initial contact resistance, max.
(By voltage drop 6 V DC 1 A)
Contact material
Rating
(resistive
load)
Expected
life
(min.ope.)
Nominal operating power
Detection current: 10mA
Excluding contact bounce time
Half-wave pulse of sine wave: 11ms; detection time: 10 s
Half-wave pulse of sine wave: 6ms
Detection time: 10 s
Refer to 5. Conditions for operation, transport and storage mentioned in
AMBIENT ENVIRONMENT (Page 24).
When using relays in a high ambient temperature, consider the pick-up voltage
rise due to the high temperature (a rise of approx. 0.4% V for each 1°C
with 20°C
maximum allowable voltage range.
Air conditioner, heater, etc.
Power-window, car antenna, door-lock,
etc.
68°F
Nominal switching capacity
Max. switching power
Max. switching voltage
Max. switching current
Mechanical (at 180 cpm)
Electrical at 10 A 125 V AC,
6 A 277 V AC resistive
(at 20 cpm)
10 A 250 V AC resistive
(at 20 cpm)
as a reference) and use a coil impressed voltage that is within the
.866
22
16
.630
16
.630
mm
250 V AC, 100 V DC
1 Form A, 1 Form C
10 A (AC), 5 A (DC)
(No contact only)
10 A 250 V AC
10 A 125 V AC
ULTRA-MINIATURE
PC BOARD TYPE
POWER RELAY
6 A 277 V AC
inch
3. Office machines
4. Vending machines
Silver alloy
2,500 VA
360 mW
100 m
5
PPC, facsimile, etc.
10
10
10
7
5
4
33.8°F
FEATURES
• Ultra-miniature size with universal terminal footprint
• High contact capacity: 10 A
• Class B coil insulation type available
• TV-5 type available
• VDE, TÜV also approved
• Sealed construction for automatic cleaning
Characteristics
Max. operating speed
Initial insulation resistance
Initial
breakdown
voltage*
Operate time*
(at nominal voltage)
Release time(without diode)*
voltage)
Temperature rise (at nominal voltage)
Shock resistance
Vibration
resistance
Conditions for operation,
transport and storage*
(Not freezing and condens-
ing at low temperature)
Unit weight
1 Form A type
1 Form C type
1
Between open contacts
Between contacts and coil
2
TV-5
TV-5 (N.O. side only)
JS RELAYS
6
Functional*
Destructive*
Functional*
Destructive
Ambient
temp.*
Humidity
2
(at nominal
7
3
5
4
Min. 100 M
Approx. 117.6 m/s
Approx. 98 m/s
Min. 980 m/s
1,500 Vrms for 1 min.
10 to 55 Hz at double
10 to 55 Hz at double
amplitude of 1.6 mm
Approx.12 g
750 Vrms for 1 min.
Min. 98 m/s
amplitude of 2 mm
–40 F to +185 F
–40 C to +85 C
Approx. 10 ms
Approx. 10 ms
5 to 85% R.H.
Max. 35 C
20 cpm
(at 500 V DC)
VDE
2
2
.423 oz
{10 G}
{100 G}
2
{10 G},
2
{12 G},