programming OK code “100” indicating the address
programming to be executed.
the MCU successfully receives the programming code
“100”. Address programming is not complete until a “100”
OK status is received by the MCU with the MI–Bus voltage
at 5.0 V.
instructions. See Figure 11.
12 V so as to have the MC33192 in the programming mode.
Programming can only be accomplished with the MI–Bus at
12 V.
Data bits D0, D1, D2 and D3 and a Logic “1” for D4 bit
followed by the programmed address bits A0, A1 and A2.
instruction. The total of the Pull time, Delay time, and Bus
Violation time (V) of the second instruction (150 s, 275 s
and 75 s respectively) will cause the memory cell to be
energized for 500 s. During the first 150 s of this time, the
MCU is checking the Pull Field Data Bits for the status of bits
S2, S1 and S0 looking for the programming code “110” to
indicate complete activation of the memory cell.
the programming OK code “100” is sent back to the MCU
from the selected MC33192 indicating the overwrite–bit
protection to be programmed. If after eight repeat
instructions, the programming code “110” or the OK code
“100” is not generated four times in succession,
programming of the MC33192 has failed. If this occurs, the
Overwrite–Bit Programming sequence should be reviewed
and re–started from the beginning.
Programming
MI–Bus Voltage
MOTOROLA ANALOG IC DEVICE DATA
The First and Second Instructions must be repeated until
Overwrite–Bit Programming involves the use of two
First Instruction Have the MI–Bus continuously set at
The MCU serially enters “Logic Zeros” for the Push Field
The MCU now waits 275 s before starting the second
Second Instruction (MI–Bus remaining at 12 V)
The MCU repeats the first instruction outlined above until
Instruction Number
Overwrite–Bit
MI–Bus Field
Strobe Pulse
Memory Cell
Status Code
Status Code
Energy in
Finished
Address
Active
5.0 V
12V
V
550 s
Push
1
Figure 11. Address Programming Diagram
150 s
“110”
“110”
Pull
500 s
275 s 75 s
Delay
MC33192
V
550 s
475 s
Push
H–Bridge Output
diagnostic encoder are shown in Figure 12. The H–Bridge
output uses internal diode clamps (D1, D2, D3, D4) to provide
transient protection of the output transistors necessary when
switching inductive loads associated with stepper motors.
Back EMF Detection
on whether the motor is running or manner in which it is being
stopped. Referring to Figure 12; When the Dir1 bit is set to
logic 0, the direction of current flow will be from V CC through
transistor Q2, Coil A (A1 to A2), and transistor Q4 to ground.
switched off).
the Inh1 bit to logic 0, the back EMF current will circulate
through the voltage supply (V CC ) and diodes D1 and D3. At
that time, the voltage developed across the diode D1 is
detected by transistor Q6. The generated voltage pulse of Q6
is then encoded and sent, in the Pull–Field, to the
microprocessor.
the E bit to logic 0, the back EMF current will circulate through
the diode D1 and transistor Q2 which is already switched on.
the Dir bit state is changed. When the Dir bit is changed from
a logic 0 to a logic 1, transistors Q2 and Q4 are switched off
and transistors Q1 and Q3 are switched on. At this time, the
back EMF current will circulate from ground through diodes
D1 and D3 to the voltage supply (V CC ). In all cases, the back
EMF currents will be detected by transistors Q5 and Q6.
The H–Bridge output drive circuit and associated
Three different Back EMF currents can occur depending
1) Fast Decay (when transistors Q1, Q2, Q3 and Q4 are
When the current flowing in the coil is stopped by setting
2) Slow Decay (Q3 and Q4 are switched off)
When the current flowing in the coil is stopped by setting
3) When Motor is Running
The rotational direction of the motor changes whenever
2
150 s
“110”
Pull
“100”
500 s
Delay
275 s 75 s
5.0 V
V
12 V
Push
3
Finished
OK
Pull
“100”
“100”
t
9