adm1027 Analog Devices, Inc., adm1027 Datasheet - Page 13

no-image

adm1027

Manufacturer Part Number
adm1027
Description
Dbcool? Remote Thermal Controller And Voltage Monitor
Manufacturer
Analog Devices, Inc.
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
adm1027-SI
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Part Number:
adm1027ARQ
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Part Number:
adm1027ARQZ
Manufacturer:
AD
Quantity:
8 852
Part Number:
adm1027RQ
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Part Number:
adm1027S1RO
Manufacturer:
AD
Quantity:
72
Part Number:
adm1027S1RO
Manufacturer:
XILINX
Quantity:
86
Part Number:
adm1027S1RQZ
Manufacturer:
RICOH
Quantity:
2 305
VID CODE MONITORING
The ADM1027 has five dedicated voltage ID (VID code) inputs.
These are digital inputs that can be read back through the
VID register (Reg. 0x43) to determine the processor voltage
required/being used in the system. Five VID code inputs
support VRM9.x solutions.
VID CODE REGISTER – Register 0x43
<0> = VID0 (reflects logic state of Pin 5)
<1> = VID1 (reflects logic state of Pin 6)
<2> = VID2 (reflects logic state of Pin 7)
<3> = VID3 (reflects logic state of Pin 8)
<4> = VID4 (reflects logic state of Pin 19)
ADDITIONAL ADC FUNCTIONS
A number of other functions are available on the ADM1027 to
offer the systems designer increased flexibility:
Turn Off Averaging
For each voltage measurement read from a value register,
16 readings have actually been made internally and the results
averaged before being placed into the value register. There may
be an instance where the user would like to speed up conversions.
Setting Bit 4 of Configuration Register 2 (Reg. 0x73) turns
averaging off. This effectively gives a reading 16¥ faster than
711 ms, but the reading may be noisier.
Bypass Voltage Input Attenuators
Setting Bit 5 of Configuration Register 2 (Reg. 0x73) removes
the attenuation circuitry from the 2.5 V, V
12 V inputs. This allows the user to directly connect external
sensors or rescale the analog voltage measurement inputs for
other applications. The input range of the ADC without the
attenuators is 0 V to 2.25 V.
REV. A
CCP
, V
CC
, 5 V, and
–13–
Single-Channel ADC Conversions
Setting Bit 6 of Configuration Register 2 (Reg. 0x73) places the
ADM1027 into single-channel ADC conversion mode. In this
mode, the ADM1027 can be made to read a single voltage channel
only. If the internal ADM1027 clock is used, the selected input
will be read every 711 ms. The appropriate ADC channel is
selected by writing to Bits <7:5> of TACH1 minimum high
byte register (0x55).
Bits <7:5> Reg. 0x55
Configuration Register 2 (Reg. 0x73)
<4> = 1 Averaging off
<5> = 1 Bypass input attenuators
<6> = 1 Single-channel convert mode
TACH1 Minimum High Byte (Reg. 0x55)
<7:5> Selects ADC channel for single-channel convert mode
000
001
010
011
100
Channel Selected
2.5 V
V
V
5 V
12 V
CCP
CC
ADM1027