ata6621n ATMEL Corporation, ata6621n Datasheet - Page 11
ata6621n
Manufacturer Part Number
ata6621n
Description
Lin Transceiver With 5v Regulator And Watchdog
Manufacturer
ATMEL Corporation
Datasheet
1.ATA6621N.pdf
(28 pages)
Available stocks
Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ATA6621N
Manufacturer:
ATMEL/爱特梅尔
Quantity:
20 000
Company:
Part Number:
ata6621n-PGQW
Manufacturer:
SMART
Quantity:
9 200
Part Number:
ata6621n-PGQW
Manufacturer:
ATMEL/爱特梅尔
Quantity:
20 000
3.15.6
3.16
3.16.1
3.16.2
3.16.3
4887H–AUTO–12/07
Wake-up Scenarios from Silent or Sleep Mode
Debug Mode
Remote Wake-up via Dominant Bus State
Local Wake-up via Pin Wake
Wake-up Source Recognition
The watchdog is switched off with pin MODE high (5V) and in normal operation if it is tied to
GND (see
Table 3-1.
A falling edge at pin LIN followed by a dominant bus level maintained for a certain time period
(t
voltage regulator is activated, and the internal slave termination resistor is switched on. The
remote wake-up request is indicated by a low level at pin RXD to generate an interrupt in the
microcontroller and a high level at pin TXD. The watchdog needs a trigger signal from PTRIG or
NTRIG within the lead time t
A falling edge at pin WAKE followed by a low level maintained for a certain time period (t
results in a local wake-up request. The extra long wake-up time (t
sients as defined in ISO7637 create a wake-up. The device switches to Pre-normal mode. The
internal slave termination resistor is switched on. The local wake-up request is indicated by a low
level at pin RXD to generate an interrupt in the microcontroller and a low level at pin TXD. The
watchdog needs a trigger signal from PTRIG or NTRIG within the lead time t
NRES.
The device can distinguish between a local wake-up request (pin WAKE) and a remote wake-up
request (dominant LIN bus state). The wake-up source can be read on pin TXD in Pre-normal
mode. A high level indicates a remote wake-up request and a low level indicates a local wake-up
request. The wake-up request flag (signalled on pin RXD) as well as the wake-up source flag
(signalled on pin TXD) are reset immediately, if the microcontroller sets pin EN to high
3-3 on page
If the ATA6621N is in Sleep mode or Silent mode and the voltage at the LIN Bus falls to a value
lower than VLINL < V
remains higher than 0.6
the pins RXD and TXD
BUS
Pre-normal
Operation
Mode of
) results in a remote wake-up request. The device switches to Pre-normal mode. The V
Normal
Sleep
Silent
Figure 5-2 on page
8).
Table of Modes
Transceiver
Off
On
Off
Off
S
(Figure 3-6 on page
– 3.3V) (see
V
D
S
, a local wake-up is indicated after the time t
to avoid resets at NRES.
24).
VCC
5V
5V
5V
0V
“Electrical Characteristics”
12).
WD_OSC
2.5V
2.5V
0V
0V
(Figure 3-3 on page
TEMP
2V
2V
0V
0V
WAKE
numbers 9.5 and 9.6) but
) ensures that no tran-
RXD
WAKE
5V
5V
5V
0V
ATA6621N
8)
D
to avoid resets at
by a low level at
RECESSIVE
RECESSIVE
RECESSIVE
RECESSIVE
LIN
(Figure
WAKE
11
CC
)