3. MLX90255BC Electrical Specifications
DC Operating Parameters T
Parameter
Notes:
(1) Reset until clock pulse 18 (on declining flank).
Minimum integration time = (133-18) * CLK period + 10µs (this is the time the S&H cap needs to follow).
At 1MHz clock speed, the minimum integration time becomes 0.125ms.
(2) At 125°C, the integration time should be limited to 2ms.
(3) The SI pulse must go low before the rising edge of the next clock pulse.
390109025503
Rev. 001
A
Symbol
= -40
o
C to 125
Test Conditions
o
C, V
DD
Page 3 of 12
= 4.5V to 5.5V (unless otherwise specified)
MLX90255-BC
Min
Linear Optical Array
Typ
Max
Units