mlx90711 ETC-unknow, mlx90711 Datasheet - Page 4

no-image

mlx90711

Manufacturer Part Number
mlx90711
Description
Position/movement Sensing Auto-shutoff
Manufacturer
ETC-unknow
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
mlx90711BA
Manufacturer:
MLX
Quantity:
6 233
Part Number:
mlx90711BC
Manufacturer:
MMELEXIS
Quantity:
20 000
Movement Auto Shut-Off time
When used as a movement Auto Shut-Off module,
several timing options are available. All timings are
derived from the on chip oscillator and have thus the
same tolerance.
If the module is left immobile for a time longer than
TASO the auto shut-off function becomes active.
There is also an additional time period TADI. This
time is valid only in the vertical state and determines
the time between shut-off and the start of the led
blinking.
version
V1
V2
V3
V4
V5
V6
V7
V8
Position Auto Shut-Off
When used as a position Auto Shut-Off module,
several timing options are available. All timings are
derived from the on chip oscillator and have thus the
same tolerance.
Three different time delays can be defined: the
horizontal shut-off (TH), the vertical shut-off (TV) and
the down shut-off (TD).
version
V1
V2
V3
V4
Start up sequence
When connecting the asic to the AC line the asic first
passes through a startup sequence. The duration of
this sequence is 1.25 or 3.75 seconds depending on
the duration of phase 1. After the start up test the
normal function of the chip begins. This sequence
MLX90711 Position/movement Sensing Auto-Shutoff Page 4
TD
30”
30”
30”
30”
Movement sensor options
position sensor options
TASO
30 sec
30 sec
4 min
1 min
10 min
2 min
8 min
30 sec
TH
30”
30”
5”
30”
TADI
0
4 min
0
0
0
0
0
8 min
TV
4’
infinity
8’
8’
Position/movement Sensing Auto-Shutoff
involves the following phases :
“TS”, which incorporates the Power On Reset time
period. This time ‘TS” is typically 0.2 sec.
seconds. This can be defined by the mask option
SPH1. During this phase the iron heats. The ASO
function is not active. The LED is off. The relay is
NC and the control voltage is not applied to its coil
during this phase.
ASO function is active. The iron is not heating. The
control voltage is applied to the coil of the relay
during this phase. The LED indicates that the ASO
function is active. Some additional information
sent out by the led driver during this phase. This
information involves three frequency codes.
(20.48kHz). The duration is 250ms.
position sensor. The frequency depends on the
position of the module:
metal mask where the customer specific options are
defined. It is coded using one of five frequencies
(20kHz, 10kHz, 5kHz, 2.5kHz, 1.25kHz).
position
UP
Between UP and HOR
HOR
Between HOR and DO
DO
EMC
Thanks to a special algorithm the sensor is made
very insensitive to noise and AC line coupling.
ESD Precautions
Electronic semiconductor products are sensitive to
Electro Static Discharge (ESD).
Always observe Electro Static Discharge control
procedures
products.
PHASE 0: The duration is a time period
PHASE 1: The duration is 0.5 second or 3
PHASE 2: The duration is 0.75 second. The
- the first code is the highest digital clock
- the second code is the information of the
- the third code is the information of the
whenever
handling
LED frequency (KHz)
1.28
2.56
5.12
10.24
20.48
MLX90711
Rev 1.0
semiconductor
15/Sep/00
is

Related parts for mlx90711