lh2320-2 Power-One, lh2320-2 Datasheet - Page 14

no-image

lh2320-2

Manufacturer Part Number
lh2320-2
Description
H Series Data Sheet 70 Watt Ac-dc Converters
Manufacturer
Power-One
Datasheet
Safety and Installation Instructions
Connector Pin Allocation
Pin no. 26 (protective earth) is leading, ensuring that it makes
contact with the female connector first.
Table 12: Pin allocation
Installation Instructions
The H Series converters are components, intended exclusively
for inclusion within other equipment by professional installers.
Installation must strictly follow the national safety regulations
in compliance with the enclosure, mounting, creepage,
clearance, casualty, markings and segregation requirements
of the end-use application.
Connection to the system shall be made via the female
connector H11. Other installation methods may not meet the
safety requirements.
The converters are provided with pin no. 26 (
reliably connected with the case. For safety reasons, it is
essential to connect this pin with the protective earth of the
supply system.
A non-accessible input fuse is connected in the line to pin 32
(L ). Since this fuse is designed to protect the converter in
case of an overcurrent and does not necessarily cover all
customer needs, an external fuse suitable for the application
and in compliance with the local requirements may be
necessary in the wiring to one or both input pins (no. 29 and/or
no. 32), particularily if the phase or neutral line cannot be
assigned to the corresponding terminals.
BCD20019 Rev AB
Electrical determination
Inhibit
Safe Data or ACFAIL
Output voltage (positive)
Output voltage (negative)
Voltage adjust
Adjust return
Output voltage (positive)
Output voltage (negative)
Output voltage (positive)
Output voltage (negative)
Protective earthing PE
AC neutral input
AC line input
1
2
Important: If the inhibit function is not in use, pin 2 (i) should be
connected with pin 23 (Vo–) to enable the output(s).
Caution: Do not open the converters, or warranty will be
invalidated.
Not connected, if option neither option D or V is fitted.
Leading pin
2
®
Pin
2
5
8
11
14
17
20
23
26
29
32
LH1000
Ident
i
D or V
Vo+
Vo–
R
G
Vo+
Vo–
N
L
1
Pin
2
5
8
11
14
17
20
23
26
29
32
LH2000
Ident
i
D or V
n.c.
n.c.
Vo2+
Vo2–
Vo1+
Vo1–
N
L
), which is
Page 14 of 21
1
Pin
2
5
8
11
14
17
20
23
26
29
32
LH3000
Protection Degree
Condition: Female connector fitted to the converter.
Standards and Approvals
The converters correspond to class I equipment and have
been approved according to the standards IEC/EN 60950-1
and UL/CSA 60950-1.
The converters have been evaluated for:
The converters are subject to manufacturing surveillance in
accordance with the above mentioned standards and with ISO
9001:2000.
Isolation
The electric strength test is performed in the factory as routine
test in accordance with EN 50116 and IEC/EN 60950, and
should not be repeated in the field. Power-One will not honor
any warranty claims resulting from electric strength field tests.
Ident
i
D or V
Vo3+
Vo3–
Vo2+
Vo2–
Vo1+
Vo1–
N
L
• IP 40: All models, except those with options D or V with a
• IP 20: All models other models.
• Class I equipment
• Building in
• Basic insulation between input and case and double or
• Functional insulation between output(s) and case
• Functional insulation between the outputs
• Pollution degree 2 environment
• Overvoltage catagory II
• Altitude up to 2000 m
potentiometer.
reinforced insulation between input and output, based on
the input voltage of 250 VAC or 400 VDC
1
Make sure that there is sufficient air flow possible
for convection cooling. This should be verified by
measuring the case temperature T
converter is installed and operated in the end-use
application.
temperature T
Thermal Considerations.
Cleaning Agents
In order to avoid possible damage, any penetration
of liquids (e.g., cleaning fluids) has to be prevented,
since the power supplies are not hermetically
sealed.
Note: All boards are coated with a protection lacquer.
Fig. 16
View of male H11 connector.
32 29 26 23 20 17 14 11 8 5 2
70 Watt AC-DC Converters
C max
The
shall not be exceeded. See also
H Series Data Sheet
maximum
www.power-one.com
specified
C
10028
, when the
case