at49lw080 ATMEL Corporation, at49lw080 Datasheet - Page 19

no-image

at49lw080

Manufacturer Part Number
at49lw080
Description
8-megabit Firmware Hub Flash Memory
Manufacturer
ATMEL Corporation
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
at49lw080-33JC
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
at49lw080-33JC
Manufacturer:
ATMEL
Quantity:
8 000
Part Number:
at49lw080-33JC
Manufacturer:
ATMEL/爱特梅尔
Quantity:
20 000
Part Number:
at49lw080-33JX
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
at49lw080-33JX SL383
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
at49lw080-33TC
Manufacturer:
SST
Quantity:
10 914
Part Number:
at49lw080-33TC
Manufacturer:
ATMEL/爱特梅尔
Quantity:
20 000
Part Number:
at49lw080-33TL
Manufacturer:
NS
Quantity:
1 373
Part Number:
at49lw080-33TL
Manufacturer:
ATMEL
Quantity:
3 524
Part Number:
at49lw080-33TL
Manufacturer:
ATMEL/爱特梅尔
Quantity:
20 000
Part Number:
at49lw080-33TX
Manufacturer:
ATMEL/爱特梅尔
Quantity:
20 000
7.6
7.7
7.8
1966G–FLASH–3/05
Program Suspend
Read Status Register
Clear Status Register
The Program Suspend command allows program interruption to read data in other memory loca-
tions. Once the program process starts, writing the Program Suspend Command requests that
the WSM suspend the program sequence at a predetermined point in the algorithm. The device
continues to output status register data when read after the program suspend command is writ-
ten. Polling the status register can help determine when the program operation was suspended.
After a successful suspend, a Read Array command can be written to read data from locations
other than that which is suspended. The only other valid commands while program is suspended
are Read Status Register and Program Resume. V
used for program) while in program suspend mode. RST or INIT must also remain at V
The status register may be read to determine when a sector erase or program completes and
whether the operation completed successfully. The status register may be read at any time by
writing the Read Status Register command. After writing this command, all subsequent read
operations will return data from the status register until another valid command is written. The
Read Status Register command functions independently of the V
Error flags in the status register can only be set to “1”s by the WSM and can only be reset by the
Clear Status Register command. These bits indicate various failure conditions. The Clear Status
Register command functions independently of the applied V
PP
must remain at V
PP
voltage.
PP
voltage.
PPH1/2
AT49LW080
(the same V
IH
.
PP
level