is42s16320b Integrated Silicon Solution, Inc., is42s16320b Datasheet - Page 27

no-image

is42s16320b

Manufacturer Part Number
is42s16320b
Description
64m X 8, 32m X 16 512mb Synchronous Dram
Manufacturer
Integrated Silicon Solution, Inc.
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
is42s16320b-6T
Manufacturer:
ISSI
Quantity:
1 000
Part Number:
is42s16320b-6TL
Manufacturer:
ISSI
Quantity:
1 060
Part Number:
is42s16320b-6TLI
Manufacturer:
NS
Quantity:
12
Part Number:
is42s16320b-6TLI
Manufacturer:
ISSI
Quantity:
2
Part Number:
is42s16320b-6TLI
Manufacturer:
ISSI
Quantity:
20 000
Company:
Part Number:
is42s16320b-6TLI
Quantity:
21
Part Number:
is42s16320b-75ETL
Manufacturer:
ISSI
Quantity:
1 000
Part Number:
is42s16320b-7BL
Manufacturer:
ISSI, Integrated Silicon Solution Inc
Quantity:
10 000
Part Number:
is42s16320b-7BLI
Manufacturer:
ISSI
Quantity:
20 000
Part Number:
is42s16320b-7TL
Manufacturer:
ISSI
Quantity:
8 000
Part Number:
is42s16320b-7TL
Manufacturer:
ISSI
Quantity:
20 000
Company:
Part Number:
is42s16320b-7TL
Quantity:
5
Company:
Part Number:
is42s16320b-7TL
Quantity:
1 600
IS42S86400B, IS42S16320B
CHIP OPERATION
BANK/ROW ACTIVATION
Before any READ or WRITE commands can be issued
to a bank within the SDRAM, a row in that bank must be
“opened.” This is accomplished via the ACTIVE command,
which selects both the bank and the row to be activated
(see Activating Specific Row Within Specific Bank).
After opening a row (issuing an ACTIVE command), a READ
or WRITE command may be issued to that row, subject to
the t
the clock period and rounded up to the next whole number
to determine the earliest clock edge after the ACTIVE
command on which a READ or WRITE command can be
entered. For example, a t
143 MHz clock (7ns period) results in 2.14 clocks, rounded
to 3. This is reflected in the following example, which cov-
ers any case where 2 < [t
procedure is used to convert other specification limits from
time units to clock cycles).
A subsequent ACTIVE command to a different row in the
same bank can only be issued after the previous active
row has been “closed” (precharged). The minimum time
interval between successive ACTIVE commands to the
same bank is defined by t
A subsequent ACTIVE command to another bank can be
issued while the first bank is being accessed, which results
in a reduction of total row-access overhead.The minimum
time interval between successive ACTIVE commands to
different banks is defined by t
EXAMPLE: MEETING TRCD (MIN) WHEN 2 < [TRCD (MIN)/TCK] ≤ 3
Integrated Silicon Solution, Inc. — www.issi.com
Rev. 00F
08/11/08
rcd
specification. Minimum t
COMMAND
rcd
rc
rcd
.
specification of 15ns with a
rrd
CLK
(MIN)/t
rcd
.
should be divided by
ck
ACTIVE
] ≤ 3. (The same
T0
t
NOP
RCD
T1
ACTIVATING SPECIFIC ROW WITHIN SPE-
CIFIC BANK
BA0, BA1
A0-A12
NOP
T2
CKE
RAS
CAS
CLK
WE
CS
HIGH
READ or
WRITE
T3
DON'T CARE
BANK ADDRESS
ROW ADDRESS
T4
27

Related parts for is42s16320b