at45db161d ATMEL Corporation, at45db161d Datasheet - Page 18

no-image

at45db161d

Manufacturer Part Number
at45db161d
Description
At45db161d 16-megabit 2.5-volt Or 2.7-volt Dataflash
Manufacturer
ATMEL Corporation
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AT45DB161D
Manufacturer:
ATMEL
Quantity:
3
Part Number:
AT45DB161D
Manufacturer:
AT
Quantity:
20 000
Part Number:
at45db161d-CCU
Manufacturer:
ATMEL
Quantity:
601
Part Number:
at45db161d-CCU
Manufacturer:
Adesto Technologies
Quantity:
10 000
Part Number:
at45db161d-CCU
Manufacturer:
ATMEL/爱特梅尔
Quantity:
20 000
Part Number:
at45db161d-CCUS
Manufacturer:
CY
Quantity:
9
Part Number:
at45db161d-CCUT
Manufacturer:
ATMEL
Quantity:
1 504
Part Number:
at45db161d-CCUT
Manufacturer:
ATMEL/爱特梅尔
Quantity:
20 000
Part Number:
at45db161d-CU
Manufacturer:
Adesto Technologies
Quantity:
10 000
Part Number:
at45db161d-MU
Manufacturer:
BROADCOM
Quantity:
101
Part Number:
at45db161d-MU-2.5
Manufacturer:
ATMEL/爱特梅尔
Quantity:
20 000
Part Number:
at45db161d-SU
Quantity:
2 330
Part Number:
at45db161d-SU
Manufacturer:
ATMEL/爱特梅尔
Quantity:
20 000
Part Number:
at45db161d-SU
Quantity:
74
10. Security Features
10.1
Figure 10-1. Sector Lockdown
18
Sector Lockdown
AT45DB161D
CS
SI
Each transition
represents 8 bits
The device incorporates a Sector Lockdown mechanism that allows each individual sector to be
permanently locked so that it becomes read only. This is useful for applications that require the
ability to permanently protect a number of sectors against malicious attempts at altering program
code or security information. Once a sector is locked down, it can never be erased or pro-
grammed, and it can never be unlocked.
To issue the Sector Lockdown command, the CS pin must first be asserted as it would be for
any other command. Once the CS pin has been asserted, the appropriate 4-byte opcode
sequence must be clocked into the device in the correct order. The 4-byte opcode sequence
must start with 3DH and be followed by 2AH, 7FH, and 30H. After the last byte of the command
sequence has been clocked in, then three address bytes specifying any address within the sec-
tor to be locked down must be clocked into the device. After the last address bit has been
clocked in, the CS pin must then be deasserted to initiate the internally self-timed lockdown
sequence.
The lockdown sequence should take place in a maximum time of t
Register will indicate that the device is busy. If the device is powered-down before the comple-
tion of the lockdown sequence, then the lockdown status of the sector cannot be guaranteed. In
this case, it is recommended that the user read the Sector Lockdown Register to determine the
status of the appropriate sector lockdown bits or bytes and reissue the Sector Lockdown com-
mand if necessary.
Opcode
Command
Sector Lockdown
Byte 1
Opcode
Byte 2
Opcode
Byte 3
Opcode
Byte 4
Byte 1
3DH
Address
Bytes
Byte 2
2AH
Address
Bytes
P
, during which time the Status
Address
Byte 3
Bytes
7FH