Page 1
... Filtered Inputs for Noise Suppression • Self time write cycle with auto clear 5 ms max.@ 2.5V • Organization: –IS24C32A/B: 4Kx8 (128 pages of 32 bytes) –IS24C64A/B: 8Kx8 (256 pages of 32 bytes) • 32 Byte Page Write Buffer • High Reliability –Endurance: 1,000,000 Cycles – ...
Page 2
... A1 A2 GND the Write Protect pin. The input level determines if all, partial, or none of the array is protected from modifications. Write Protection Array Addresses Protected WP IS24C32A/64A GND or floating Vcc Entire Array Integrated Silicon Solution, Inc. — 1-800-379-4774 ISSI ® HIGH VOLTAGE GENERATOR, TIMING & ...
Page 3
... IS24C32A/B IS24C64A/B DEVICE OPERATION IS24CXX features serial communication and supports a bi- directional 2-wire bus transmission protocol called I 2-WIRE BUS The two-wire bus is defined as a Serial Data line (SDA), and a Serial Clock line (SCL). The protocol defines any device that sends data onto the SDA bus as a transmitter, and the receiving devices as receivers ...
Page 4
... IS24C32A/B IS24C64A/B DEVICE ADDRESSING The Master begins a transmission by sending a Start condition. The Master then sends the address of the particular Slave devices it is requesting. The Slave device (Fig. 5) address is 8 bits. The four most significant bits of the Slave address are fixed as 1010 for the IS24CXX. ...
Page 5
... Read operation. When the memory address boundary of 8191 for IS24C64A/B or 4095 for IS24C32A/B (depending on the device) is reached, the address counter “rolls over” to address 0, and the device continues to output data ...
Page 6
... IS24C32A/B IS24C64A/B Figure 1. Typical System Bus Configuration SDA SCL Figure 2. Output Acknowledge SCL from Master Data Output from Transmitter Data Output from Receiver Figure 3. START and STOP Conditions SCL SDA 6 Vcc Master Transmitter/ IS24CXX Receiver Integrated Silicon Solution, Inc. — 1-800-379-4774 ISSI ® ...
Page 7
... IS24C32A/B IS24C64A/B Figure 4. Data Validity Protocol SCL SDA Figure 5. Slave Address BIT Figure 6. Byte Write Device R Address T SDA Bus Activity Figure 7. Page Write Device R T Word Address (n) Address T E SDA A Bus Activity R/W Integrated Silicon Solution, Inc. — 1-800-379-4774 Rev ...
Page 8
... IS24C32A/B IS24C64A/B Figure 8. Current Address Read Activity Figure 9. Random Address Read Device R T Address T E SDA A Bus C Activity R/W DUMMY WRITE Figure 10. Sequential Read R E Device A Address D SDA A Bus C K Activity R Device A T Address ...
Page 9
... OPERATING RANGE (IS24C64A/B-2 and IS24C32A/B-2) Range Ambient Temperature Industrial –40°C to +85°C Note: ISSI offers Industrial grade for Commerical applications (0 OPERATING RANGE (IS24C64A/B-3 and IS24C32A/B-3) Range Ambient Temperature Automotive –40°C to +125°C CAPACITANCE (1,2) Symbol ...
Page 10
... IS24C32A/B IS24C64A/B AC WAVEFORMS Figure 11. Bus Timing t R SCL t SU:STA SDA IN SDA OUT WP Figure 12. Write Cycle Timing SCL 8th BIT SDA WORD HIGH LOW t HD:DAT t t HD:STA SU:DAT ACK t WR STOP Condition Integrated Silicon Solution, Inc. — 1-800-379-4774 ...
Page 11
... IS24C32A/B IS24C64A/B DC ELECTRICAL CHARACTERISTICS Symbol Parameter V 1 Output Low Voltage Output Low Voltage OL V Input High Voltage IH V Input Low Voltage IL I Input Leakage Current LI I Output Leakage Current LO Notes: V min and V max are reference only and are not tested. ...
Page 12
... IS24C32A/B IS24C64A/B AC ELECTRICAL CHARACTERISTICS Symbol Parameter f SCL Clock Frequency SCL T Noise Suppression Time t Clock Low Period Low t Clock High Period High t Bus Free Time Before New Transmission BUF t Start Condition Setup Time SU:STA t Stop Condition Setup Time SU:STO t Start Condition Hold Time ...
Page 13
... IS24C32A/B IS24C64A/B ORDERING INFORMATION Industrial Range: -40°C to +85°C, Lead-free Voltage Range Part Number 1.8V IS24C32A-2PLI to 5.5V IS24C32A-2GLI IS24C32A-2ZLI IS24C32A-2SLI 1.8V IS24C32B-2PLI to 5.5V IS24C32B-2GLI IS24C32B-2ZLI 1.8V IS24C64A-2PLI to 5.5V IS24C64A-2GLI IS24C64A-2ZLI IS24C64A-2SLI 1.8V IS24C64B-2PLI to 5.5V IS24C64B-2GLI IS24C64B-2ZLI ORDERING INFORMATION Industrial Range: -40°C to +85°C Voltage Range Part Number 1.8V IS24C32A-2PI to 5.5V IS24C32A-2GI IS24C32A-2ZI 1 ...
Page 14
... ISSI reserves the right to make changes to its products at any time without notice in order to improve design and supply the best possible product. We assume no responsibility for any errors which may appear in this publication. © Copyright 2002, Integrated Silicon Solution, Inc. Integrated Silicon Solution, Inc. — 1-800-379-4774 Rev ...
Page 15
... Copyright © 2003 Integrated Silicon Solution, Inc. All rights reserved. ISSI reserves the right to make changes to this specification and its products at any time without notice. ISSI assumes no liability arising out of the application or use of any information, products or services described herein. Customers are advised to obtain the latest version of this device specification before relying on any published information and before placing orders for products. Integrated Silicon Solution, Inc. — ...
Page 16
... Ref. Std. Inches No. Leads 8 A — 0.068 A1 0.004 0.009 B 0.013 0.020 C 0.007 0.010 D 0.189 0.197 E 0.150 0.157 H 0.228 0.245 e 0.050 BSC L 0.020 0.035 Integrated Silicon Solution, Inc. — 1-800-379-4774 Rev. C 10/03/ SEATING PLANE Min Max mm 8 — 1.73 0.1 0.23 0.33 0.51 0.18 0.25 4.8 5 3.81 3.99 5.79 6.22 1.27 BSC ...
Page 17
... SSI reserves the right to make changes to its products at any time without notice in order to improve design and supply the best possible product. We assume no responsibility for any errors which may appear in this publication. © Copyright 2002, Integrated Silicon Solution, Inc. Integrated Silicon Solution, Inc. ...