mlx16303 Melexis Company, mlx16303 Datasheet

no-image

mlx16303

Manufacturer Part Number
mlx16303
Description
Bi-directional Remote Sensor Unit Interface
Manufacturer
Melexis Company
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
mlx16303GC
Manufacturer:
MXL
Quantity:
20 000
Features and Benefits
Application
Ordering Information
Part No.
MLX16303
1. Functional Diagram
3901016303
Rev. 004
SSIO0
SSIO1
Rtrip
Vdd
Vs
Vp
Two identical interface channels for remote sensor units
Two connection modes: connection to OUTx and RETx or connection to OUTx and GND
pin
16 bit Standard SPI for control and diagnosis via a microcontroller
Supply voltage for each remote unit with a supply current up to 45mA
Current limitation with an analog feed back loop for each channel
Receive data from the remote unit by current modulation with a transmission rate of
10kHz
Transmission of data to the remote unit via PWM voltage pulses
Data input/output can be directly connected to a microcontroller input/output (CMOS)
Low current consumption
All pins to the external interface are short-circuit and high-voltage protected
High immunity against cross coupling between the two channels
The current modulation provides high noise immunity for data transfer
Remote automotive sensors (between ECU and sensors).
Transceiver for
Transceiver for
(Temperature, short circuit, open circuit)
Voltage supply
conversion or
conversion or
PWM pulses
PWM pulses
for sending
for sending
CLK
reference
Current
current
current
16 bit SPI interface
Diagnosis circuit
CS
DI
Remote unit
Remote unit
driver
driver
Power on
reset
Temperature Suffix
E (-40° C to 85° C)
DO
Bi-directional Remote Sensor Unit Interface
OUT0
GND0
OUT1
GND1
RET0
RET1
Page 1 of 20
2. Description
This interface IC is designed for remote
automotive sensors, especially between a
main ECU and remote (sensor) units. It
contains two identical interfaces and the
main task of each interface is to supply one
remote unit and to receive digital information
from the same remote unit. It is also
possible to send data as PWM voltage
pulses to the remote unit, for example to
program the remote unit for its special
application. This is done by one active wire:
the interface supplies the external unit with
a pre-regulated voltage, the external unit
transmits the digital information back to the
interface by current modulation. A
continuous diagnosis of the IC is running in
the background. The diagnosis results can
be requested by a microcontroller using the
SPI interface.
DC (SOIC16, 150 mil)
Package Code
MLX16303
Data Sheet
Jun/04

Related parts for mlx16303

mlx16303 Summary of contents

Page 1

... OUT1 transmits the digital information back to the interface by current modulation. A RET1 continuous diagnosis of the IC is running in GND1 the background. The diagnosis results can be requested by a microcontroller using the SPI interface. DO Page MLX16303 Package Code DC (SOIC16, 150 mil) Data Sheet Jun/04 ...

Page 2

... FEATURES AND BENEFITS ....................................................................................................................... 1 APPLICATION .............................................................................................................................................. 1 ORDERING INFORMATION......................................................................................................................... 1 1. FUNCTIONAL DIAGRAM................................................................................................................... 1-1 2. DESCRIPTION.................................................................................................................................... 2-1 3. ABSOLUTE MAXIMUM RATINGS ....................................................................................................... 3 4. MLX16303 ELECTRICAL SPECIFICATIONS ...................................................................................... 6 5. GENERAL DESCRIPTION .................................................................................................................. 11 6. UNIQUE FEATURES........................................................................................................................... 18 7. RELIABILITY INFORMATION............................................................................................................. 19 8. ESD PRECAUTIONS........................................................................................................................... 19 9. DISCLAIMER ....................................................................................................................................... 20 3901016303 Rev. 004 Bi-directional Remote Sensor Unit Interface TABLE OF CONTENTS ...

Page 3

... Absolute Maximum Ratings All voltages are referenced to the GND pins potential if no other voltage potential is mentioned. Parameter 3901016303 Rev. 004 Bi-directional Remote Sensor Unit Interface Symbol Page MLX16303 min. max. Unit Data Sheet Jun/04 ...

Page 4

... Pinout 3901016303 Rev. 004 Bi-directional Remote Sensor Unit Interface Symbol 1 SSIO1 RETURN1 16 2 VDD (5V) VSS ret1 15 3 RTRIP OUT1 OUT0 11 7 CLK VSS 10 8 SSIO0 RETURN 0 9 Page MLX16303 min. max. Unit Data Sheet Jun/04 ...

Page 5

... Pin description 3901016303 Rev. 004 Bi-directional Remote Sensor Unit Interface Page MLX16303 Data Sheet Jun/04 ...

Page 6

... MLX16303 electrical specifications Tamb = -40 to 85° C and Tj = -40 to 150°C VS operation supply voltage range 4.9V to 7.7 V (Remote unit connection OUTx to RETx pin operation supply voltage range 6.0V to 7.7 V (Remote unit connection OUTx to GND pin) VP programming voltage range 9.6V to 16.2V All voltages are referenced to the GND pins potential if no other voltage potential is mentioned ...

Page 7

... Itrip: specified value is for Vdd=5V (treshold is relative to Vdd) OUT0 and OUT1 Short Circuit to GND Short Circuit to battery Short Circuit to according RETURNx (1) Definition of theoretical equation of Ithreshold: Ithreshold (mA) = 960/Rtrip (kOhms) 3901016303 Rev. 004 Bi-directional Remote Sensor Unit Interface Page MLX16303 Data Sheet Jun/04 ...

Page 8

... Non Programming Mode: connection OUTx to RETx Programming Mode: connection OUTx to RETx Non Programming Mode: connection OUTx to GND Programming Mode: connection OUTx to GND 3901016303 Rev. 004 Bi-directional Remote Sensor Unit Interface Page MLX16303 Data Sheet Jun/04 ...

Page 9

... Edges during voltage PWM ( programming mode) RETURN0, RETURN1 SSIO0, SSIO1 (bidirectional CMOS) 3901016303 Rev. 004 Bi-directional Remote Sensor Unit Interface Page MLX16303 Data Sheet Jun/04 ...

Page 10

... Response time at SSIOx to current change SPI signals (CMOS) Power dissipation 3901016303 Rev. 004 Bi-directional Remote Sensor Unit Interface Page MLX16303 Data Sheet Jun/04 ...

Page 11

... VP is connected to the battery via a reverse polarity protection diode (KL15). The VP pin may not source current under all conditions, especially after battery cut off. VDD (5V Voltage) Additional to the VS and VP MLX16303 needs a low current 5V voltage for the digital part and reference use. This voltage is named VDD. ...

Page 12

... The IC gets 16bit data from the microcontroller via SPI. The bit will be interpreted as a command. The other bits are data. When a command word is sent to the MLX16303 the first bit on the data bus must be bit0 (LSB) followed by the bits 1-15. The first bit of the answer word from MLX16303 must be bit0 followed by the bits 1-15. ...

Page 13

... CS0 Selection of channel 0 0: channel 0 not selected 1: channel 0 selected Answer MSB 3901016303 Rev. 004 Bi-directional Remote Sensor Unit Interface Page MLX16303 Data Sheet LSB 0 LSB 0 Jun/04 ...

Page 14

... If the CMD is sent during the programming mode, the answer will be the same as for a wrong command 3901016303 Rev. 004 Bi-directional Remote Sensor Unit Interface Page MLX16303 Data Sheet LSB 0 LSB 0 ...

Page 15

... Request of the actual diagnosis result of the bi-directional remote unit interface IC after an error has occurred, the channel was switched off and the exact errortyp (checked with CMD_DIAG1) is still unclear. 3901016303 Rev. 004 Bi-directional Remote Sensor Unit Interface Page MLX16303 Data Sheet LSB 0 LSB 0 ...

Page 16

... Answer MSB CMD_NOP No Operation allows ECU to poll the answer of a previous command. 3901016303 Rev. 004 Bi-directional Remote Sensor Unit Interface Page MLX16303 Data Sheet LSB 0 LSB 0 Jun/04 ...

Page 17

... Command MSB Answer Both bytes are reflected. MSB 3901016303 Rev. 004 Bi-directional Remote Sensor Unit Interface Page MLX16303 Data Sheet LSB 0 LSB 0 Jun/04 ...

Page 18

... If an error is detected the relevant channel will be switched off. After an error occurred it will be latched. The latched errors can only be reset by sending a CMD_ONOFF to the MLX16303. The ECU can read out the detected errors using the SPI interface. The error detection in MLX16303 reacts before any damaging or unreliable operation can occur. ...

Page 19

... For more information on manufacturability/solderability see quality page at our website: http://www.melexis.com/html/pdf/MLXleadfree-statement.pdf 8. ESD Precautions Electronic semiconductor products are sensitive to Electro Static Discharge (ESD). Always observe Electro Static Discharge control procedures whenever handling semiconductor products. 3901016303 Rev. 004 Bi-directional Remote Sensor Unit Interface Page MLX16303 Data Sheet Jun/04 ...

Page 20

... Bi-directional Remote Sensor Unit Interface www.melexis.com Or for additional information contact Melexis Direct: Europe and Japan: All other locations: Phone: + Phone: +1 603 223 2362 E-mail: sales_europe@melexis.com E-mail: sales_usa@melexis.com ISO/ TS 16949 and ISO 14001 Certified Page MLX16303 Data Sheet Jun/04 ...