ap2146 Diodes, Inc., ap2146 Datasheet

no-image

ap2146

Manufacturer Part Number
ap2146
Description
0.5a Dual Channel Current-limited Power Switch
Manufacturer
Diodes, Inc.
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ap2146ASG-13
Manufacturer:
DIODES
Quantity:
1 254
Part Number:
ap2146ASG-13
Manufacturer:
DIODES/美台
Quantity:
20 000
Company:
Part Number:
ap2146ASG-13
Quantity:
22 423
Part Number:
ap2146SG-13
Manufacturer:
DIODES
Quantity:
120
Part Number:
ap2146SG-13
Manufacturer:
DIODES/美台
Quantity:
20 000
Features
Applications
Typical Application Circuit
Available Options
AP2146/AP2156 Rev 1
Part Number
AP2146
AP2156
Power Supply
Dual USB port power switches
Over-current and thermal protection
0.8A accurate current limiting
Reverse Current Blocking
90mΩ on-resistance
Input voltage range: 2.7V – 5.5V
0.6ms typical rise time
Very low shutdown current: 1uA (max)
Fault report (FLG) with blanking time (7ms typ)
ESD protection: 6KV HBM, 300V MM
Active high (AP2146) or active low (AP2156) enable
Ambient temperature range -40ºC to 85°C
SOP-8L and MSOP-8L-EP (Exposed Pad): Available in
“Green” Molding Compound (No Br, Sb)
Lead Free Finish / RoHS Compliant (Note 1)
UL Recognized, File Number E322375
IEC60950-1 CB Scheme Certified
Consumer electronics – LCD TV & Monitor, Game Machines
Communications – Set-Top-Box, GPS, Smartphone
Computing – Laptop, Desktop, Servers, Printers, Docking Station, HUB
2.7V to 5.5V
Channel
10k
2
2
10k
OFF
ON
10uF
Enable Pin (EN)
Active High
Active Low
0.1uF
www.diodes.com
0.5A DUAL CHANNEL CURRENT-LIMITED POWER
1 of 17
IN
FLG2
EN1
EN2
FLG1
Description
The AP2146 and AP2156 are integrated high-side power switches
optimized for Universal Serial Bus (USB) and other hot-swap
applications. The family of devices complies with USB 2.0 and
available with both polarities of Enable input. They offer current
and thermal limiting and short circuit protection as well as
controlled rise time and under-voltage lockout functionality. A 7ms
deglitch capability on the open-drain Flag output prevents false
over-current reporting and does not require any external
components.
All devices are available in SOP-8L and MSOP-8L-EP packages.
GND
Current Limit
OUT1
OUT2
(Typical)
0.8A
0.8A
0.1uF
0.1uF
AP2146/AP2156
Recommended Maximum
Continuous Load Current
68uF
68uF
0.5A
0.5A
©
Diodes Incorporated
Load
Load
APRIL 2009
SWITCH

Related parts for ap2146

ap2146 Summary of contents

Page 1

... AP2146/AP2156 Rev 1 0.5A DUAL CHANNEL CURRENT-LIMITED POWER Description The AP2146 and AP2156 are integrated high-side power switches optimized for Universal Serial Bus (USB) and other hot-swap applications. The family of devices complies with USB 2.0 and available with both polarities of Enable input. They offer current and thermal limiting and short circuit protection as well as controlled rise time and under-voltage lockout functionality ...

Page 2

... Pad layout as shown on Diodes Inc. suggested pad layout document AP02001, which can be found on our website at http://www.diodes.com/datasheets/ap02001.pdf. Pin Assignment ( Top View ) EN1 1 2 FLG1 FLG2 3 4 EN2 SOP-8L AP2146/AP2156 Rev 1 0.5A DUAL CHANNEL CURRENT-LIMITED POWER Package G : Green S : SOP- MSOP-8L-EP Packaging (Note 2) Quantity SOP-8L 2500/Tape & Reel MSOP-8L-EP 2500/Tape & ...

Page 3

... Pin Descriptions Pin Name Pin Number EN1 1 Switch 1 enable input, active low (AP2146) or active high (AP2156) FLG1 2 Switch 1 over-current and over-temperature fault report, open-drain FLG2 3 Switch 2 over-current and over-temperature fault report, open-drain EN2 4 Switch 2 enable input, active low (AP2146) or active high (AP2156) ...

Page 4

... Storage Temperature Range (Note 3) ST Notes Recognized Rating from -30°C to 70°C Recommended Operating Conditions Symbol V Input voltage IN I Output Current OUT Operating Ambient Temperature T A AP2146/AP2156 Rev 1 0.5A DUAL CHANNEL CURRENT-LIMITED POWER Parameter Parameter www.diodes.com AP2146/AP2156 SWITCH Ratings Units 6 KV 300 V 6.5 ...

Page 5

... Test condition for SOP-8L: Device mounted on FR-4 2-layer board, 2oz copper, with minimum recommended pad layout. 5. Test condition for MSOP-8L-EP: Device mounted on FR-4 2-layer board, 2oz copper, with minimum recommended pad on top layer and 3 vias to bottom layer ground plane. AP2146/AP2156 Rev 1 AP2146/AP2156 0.5A DUAL CHANNEL CURRENT-LIMITED POWER ...

Page 6

... V EN 50% 50 D(ON) 90% V OUT 10% Figure 1. Voltage Waveforms: AP2146 (left), AP2156 (right) All Enable Plots are for AP2146 Active Low Channel 1 Turn-On Delay and Rise Time Ven 1 5V/div Vout 1 2V/div 500us/div Channel 2 Turn-On Delay and Rise Time Ven 2 5V/div Vout 2 2V/div ...

Page 7

... Vout 2 2V/div 500us/div Channel 1 Short Circuit Current, Device Enabled Into Short Ven 1 5V/div Iout 1 200mA/div 500us/div AP2146/AP2156 Rev 1 0.5A DUAL CHANNEL CURRENT-LIMITED POWER (Continued) Channel 1 Turn-Off Delay and Fall Time Ven 1 5V/div Vout 1 2V/div C L =100uF T A =25° =10Ω Channel 2 Turn-Off Delay and Fall Time ...

Page 8

... Channel 1 1 Ω Load Connected to Enabled Device Vflag 1 2V/div Iout 1 1A/div 2ms/div Channel 2 1 Ω Load Connected to Enabled Device Vflag 2 2V/div Iout 2 1A/div 2ms/div AP2146/AP2156 Rev 1 AP2146/AP2156 0.5A DUAL CHANNEL CURRENT-LIMITED POWER (Continued) Channel 2 Inrush Current Ven 2 5V/div C =100uF V = =25°C ...

Page 9

... Iout 200mA/div Ven 5V/div Vin 5V/div 1ms/div Channel 1 UVLO Increasing Vin 2V/div Iout 200mA/div 1ms/div AP2146/AP2156 Rev 1 AP2146/AP2156 0.5A DUAL CHANNEL CURRENT-LIMITED POWER (Continued) Short Circuit with Blanking Time and Recovery V IN =5V Vout 5V/div T A =25° =22uF Vflag 5V/div Iout 1A/div ...

Page 10

... Channel 1 Enabled and Shorted with Channel 2 Disabled Vout 1 5V/div Vout 2 5V/div Vflag 1 5V/div Iout 2 500mA/div 100ms/div AP2146/AP2156 Rev 1 0.5A DUAL CHANNEL CURRENT-LIMITED POWER (Continued) Channel 2 UVLO Decreasing Vin 2V/div T A =25° =22uF R L =10Ω Iout 200mA/div Channel 1 Disabled and Channel 2 Enabled ...

Page 11

... Input Voltage (V) Supply Current, Output Enabled vs Ambient Temperature 65 60 Vin=5.0V 55 Vin=5. Vin=3. -60 -40 - Ambient Temperature (°C) AP2146/AP2156 Rev 1 0.5A DUAL CHANNEL CURRENT-LIMITED POWER (Continued =1uF L R =10Ω =25° 4.5 5 5 ...

Page 12

... Ambient Temperature (°C) Current Limit Response vs Peak Current Peak Current (A) AP2146/AP2156 Rev 1 0.5A DUAL CHANNEL CURRENT-LIMITED POWER (Continued) Short-Circuit Output Current vs Ambient Temperature 710 700 Vin=2.7V 690 680 670 660 650 640 Vin=5V 630 100 ...

Page 13

... In the third condition, the load has been gradually increased beyond the recommended operating current. The current is permitted to rise until the current-limit threshold (I the device is exceeded. The AP2146/AP2156 is capable of delivering current up to the current-limit threshold without damaging the device. Once the threshold has been reached, the device switches into its current limiting mode and is set at I ...

Page 14

... Thermal Protection Thermal protection prevents the IC from damage when heavy-overload or short-circuit faults are present for extended periods of time. The AP2146/AP2156 implements a thermal sensing to monitor the operating junction temperature of the power distribution switch. Once the die temperature rises to approximately 140°C due to excessive power dissipation in an over-current or short-circuit condition the internal thermal sense circuitry turns the power switch off, thus preventing the power switch from damage. Hysteresis is built into the thermal sense circuit allowing the device to cool down approximately 25° ...

Page 15

... Due to the controlled rise times and fall times of the AP2146/AP2156, these devices can be used to provide a softer start-up to devices being hot-plugged into a powered system. The UVLO feature of the AP2146/AP2156 also ensures that the switch is off after the card has been removed, and that the switch is off during the next insertion. ...

Page 16

... Land Pattern Recommendation (Unit: mm) (2) Package type: MSOP-8L-EP 1 0.22/0.38 0.65Bsc. 0.05 2.9/3.1 1 EXPOSED PAD (BOTTOM) 1.65/1.95 AP2146/AP2156 Rev 1 0.5A DUAL CHANNEL CURRENT-LIMITED POWER (All Dimensions in mm) Gauge Plane Seating Plane 0.62/0.82 Detail "A" 7°~9° 0.35max. 45° Detail "A" 0°/8° EXPOSED PAD 8x-0.45 (BOTTOM) 6x-0.65 1 ...

Page 17

... Customers must fully indemnify Diodes Incorporated and its representatives against any damages arising out of the use of Diodes Incorporated products in such safety-critical, life support devices or systems. Copyright © 2009, Diodes Incorporated www.diodes.com AP2146/AP2156 Rev 1 AP2146/AP2156 0.5A DUAL CHANNEL CURRENT-LIMITED POWER IMPORTANT NOTICE LIFE SUPPORT www ...