saa-200k002s-2z Tai-Shing., Ltd, saa-200k002s-2z Datasheet

no-image

saa-200k002s-2z

Manufacturer Part Number
saa-200k002s-2z
Description
Solid State Relays Ac Control Ac Loading S.s.r
Manufacturer
Tai-Shing., Ltd
Datasheet
SAA-200K002S-2Z
SAA-200K004S-2Z
SAA-200K006S-2Z
SAA-200K002S-2Z
SAA-200K004S-2Z
SAA-200K006S-2Z
MODEL SERIES NO. CONTROL VOLTAGE MUST TURN OFF VOLTAGE INPUT IMPEDANCE LOADING CURRENT
MODEL SERIES NO.
Characteristic Curves
Specifications
Parts No
SAA- 200 K 002 S - 2 Z
Outline Dimensions
70
60
55
40
30
20
10
0
30
25
20
15
10
5
0
0.01
(1)
(2)
(3)
Input Current VS. Input Voltage
5
Peak Surge Current VS
10
Duration (sec)
0.1
Input Voltage(V)
80 - 280 VAC
80 - 280 VAC
80 - 280 VAC
MAX OFF
STATE dv/dt
100 V/ sec
100 V/ sec
200 V/ sec
10.16
Duration
(1)SAA-200K002S-2Z
(2)
(3)
SAA-200K004S-2Z
SAA-200K006S-2Z
15
37.0
μ
μ
μ
.
1
20
12.7 5.08
1
25
MAX ON-STATE
VOLTAGE DROP ISOLATE IMPEDENCE
MAX 10 VDC
MAX 10 VDC
MAX 10 VDC
10
2.0Vrms
2.0Vrms
2.0Vrms
30
SAA SERIES SOLID STATE RELAY
AC Control AC Loading S.S.R
3.0
2.5
2.0
1.5
1.0
0.5
0
6
5
4
3
2
1
0 -20
-20
SAA-200K006S-2Z
Maximum Load Current VS.
SAA-200K004S-2Z
Maximum Load Current VS.
10 Ω
10 Ω
10 Ω
SAA-200K002S-2Z
1.5 KΩ
1.5 KΩ
1.5 KΩ
0
SAA-200K002S-2Z
SAA-200K004S-2Z
SAA-200K006S-2Z
Ambient Temperature
Ambient Temperature
Ambient Temperature( C)
9
9
9
0
(Unit : mm)
Ambient Temperature( C)
PICK UP VOLTAGE
DROP OUT VOLTAGE
20
20
8
4- 1.0
5.0
40
40
Ø
2500 VACrms
2500 VACrms
DIELECTRIC STRENGTH
INPUT-OUTPUT
2500 VACrms
±
1
60
60
0.5
2A
4A
6A
80
Loading Current : 002 = 2A,004 = 4A,006 = 6A
80
Switching Type : Z = Zero-Crossing
Packing : 2 = SIP of Seal Type
Phase : S = Single Phase
Control Voltage : K = 80~280VAC
Loading Voltage : 200 = 24~280VAC
Control Type : AA = AC Control AC
S = S.S.R
100
100
LOADING VOLTAGE MIN BLOCKING VOLTAGE MAX OFF-STATE LEAKAGE
DIELECTRIC STRENGTH
INPUT,OUTPUT-CASE
24 ~ 280VAC
24 ~ 280VAC
24 ~ 280VAC
TURN ON TIME TURN OFF TIME
LESS 2 msec
LESS 2 msec
LESS 2 msec
600VAC
600VAC
600VAC
AC IN
~
~
SIP of Seal Series
Equivalent Circuit
temminats. See also above.
In order to be in compliance with the EMC
In order to be in compliance with the EMC
Directive an additional X2 capacitor at the
Directive an additional X2 capacitor at the
single component.
single component.
incorporated in an appliance the existing
incorporated in an appliance the existing
EMI filter may provide the required EMI
EMI filter may provide the required EMI
suppresion.
suppresion.
placed as close as possible to the output
placed as close as possible to the output
output is requried if the SSR is operated as
output is requried if the SSR is operated as
Attention:
1.Input Circuit
2.Zero-Crossing Circuit
3.Output Circuit
4.Protected Circuit
1
10.16
LESS 1/2 AC CYCLE
LESS 1/2 AC CYCLE
LESS 1/2 AC CYCLE
LESS 5 mA
LESS 5 mA
LESS 5 mA
The X2 capacitor must be
The X2 capacitor must be
12.7
2
CAPACITANCE IN-OUT WEIGHT (g)
FREQUENCY RANGE
In case the SSR is
In case the SSR is
LESS 15 PF
LESS 15 PF
LESS 15 PF
47-70HZ
47-70HZ
47-70HZ
3
5.08
4 OUT
0.22 uF/AC275V
MAX 1-CYCLE
PEAK SURGE
~
4- 1.0
C1 X2
Ø
12 g
12 g
12 g
20A
40A
60A

Related parts for saa-200k002s-2z

Related keywords