acpl-w611 Avago Technologies, acpl-w611 Datasheet

no-image

acpl-w611

Manufacturer Part Number
acpl-w611
Description
High Cmr, High Speed Ttl Compatible Optocoupler
Manufacturer
Avago Technologies
Datasheet
ACPL-W611/ACPL-P611
High CMR, High Speed TTL Compatible Optocoupler
Data Sheet
Description
The ACPL-W611/ACPL-P611 is an optically coupled gate
that combines a GaAsP light emitting diode and an inte-
grated high gain photo detector. The output of the de-
tector IC is an open collector Schottky clamped transis-
tor. The internal shield provides a guaranteed common
mode transient immunity specification of 10,000 V/μs for
the ACPL-W611.
This unique design provides maximum ac and dc circuit
isolation while achieving TTL compatibility. The opto-
coupler ac and dc operational parameters are guaran-
teed from -40°C to +85°C allowing trouble-free system
performance.
The ACPL-W611/ACPL-P611 is suitable for high speed
logic interfacing, input/output buffering, as line
receivers in environments that conventional line receiv-
ers cannot tolerate and are recommended for use in ex-
tremely high ground or induced noise environments.
Functional Diagram
RoHS 6 fully compliant options available;
-xxxE denotes a lead-free product
CATHODE
A 0.1 μF bypass capacitor must be connected be-
tween pins V
ANODE
Lead (Pb) Free
RoHS 6 fully
compliant
CAUTION: It is advised that normal static precautions be taken in handling and assembly
of this component to prevent damage and/or degradation which may be induced by ESD.
ACPL-W611/ACPL-P611
1
2
3
CC
LED
ON
OFF
(POSITIVE LOGIC)
and GND.
TRUTH TABLE
SHIELD
OUTPUT
H
L
6
5
4
V
V
GND
CC
O
Features
x 10 kV/μs minimum Common Mode Rejection (CMR)
x High speed: 10 MBd typical
x LSTTL/TTL compatible
x Low input current capability: 5 mA
x Guaranteed ac and dc performance over temperature:
x Stretched SO-6 package
x Safety Approval:
Applications
x Isolated line receiver
x Computer-peripheral interfaces
x Microprocessor system interfaces
x Digital isolation for A/D, D/A conversion
x Switching power supply
x Instrument input/output isolation
x Ground loop elimination
x Pulse transformer replacement
x Power transistor isolation in motor drives
x Isolation of high speed logic systems
at VCM = 1000 V
-40°C to +85°C
– UL Recognized:
– CSA
– IEC/EN/DIN EN 60747-5-2
5000Vrms for 1 minute for ACPL-W611 and ACPL-
P611-020E per UL1577

Related parts for acpl-w611

acpl-w611 Summary of contents

Page 1

... Low input current capability Guaranteed ac and dc performance over temperature: -40°C to +85°C x Stretched SO-6 package x Safety Approval: – UL Recognized: 5000Vrms for 1 minute for ACPL-W611 and ACPL- P611-020E per UL1577 – CSA – IEC/EN/DIN EN 60747-5-2 Applications x Isolated line receiver x Computer-peripheral interfaces ...

Page 2

... – 3 SHIELD Ordering Information ACPL-P611 is UL Recognized with 3750Vrms for 1 minute and ACPL-W611 is UL recognized with 5000Vrms for 1 min- ute per UL1577. They are approved under CSA Component Acceptance Notice #5, File CA 88324. Option Part number RoHS Compliant -000E -020E ...

Page 3

... Package Outline Drawings ACPL-W611 Stretched SO-6 Package 0.381 (0.015 7° 0.450 (0.018) 45° 0.200 ± 0.100 (0.008 ± 0.004) 6.807 (0.268) 0.750 (0.0295) 11.500 ± 0.300 (0.453 ± 0.012) ACPL-P611 Stretched SO-6 Package 0.38 ± 0.127 (0.015 ± 0.005 7.62 (0.300) 6.81 (0.268) 0.450 (0.018) 0.20 ± ...

Page 4

... SEC. 30 SEC. 50 SEC. 100 150 200 TIME (SECONDS) Regulatory Information The ACPL-W611 and ACPL-P611 is approved/pending ap- proval by the following organizations: TIME WITHIN 5 °C of ACTUAL PEAK TEMPERATURE IEC/EN/DIN EN 60747-5-2 (Option 060 only) 20-40 SEC. Approval under: IEC 60747-5-2 :1997 + A1:2002 EN 60747-5-2:2001 + A1:2002 RAMP-DOWN 6 ° ...

Page 5

... Insulation and Safety Related Specifications Parameter Symbol Minimum External Air Gap L(101) Clearance) Minimum External Tracking L(102) (External Creepage) Minimum Internal Plastic Gap (Internal Clearance) Tracking Resistance CTI (Comparative Tracking Index) Isolation Group 5 ACPL-P611 ACPL-W611 Units 0.08 0.08 mm 175 175 V IIIa IIIa Conditions ...

Page 6

... IEC/EN/DIN EN 60747-5-2 Insulation Characteristics* (ACPL-W611/ ACPL-P611 Option 060) Description Installation classification per DIN VDE 0110/1.89, Table 1 for rated mains voltage ≤ 150 V rms for rated mains voltage ≤ 300 V rms for rated mains voltage ≤ 450 V rms for rated mains voltage ≤ 600 V rms for rated mains voltage ≤ ...

Page 7

Absolute Maximum Ratings Parameter Storage Temperature Operating Temperature Average Input Current Reverse Input Voltage Input Power Dissipation Supply Voltage (1 Minute Maximum) Output Collector Current Output Collector Voltage Output Collector Power Dissipation Lead Solder Temperature Solder Reflow Temperature Profile Recommended ...

Page 8

Switching Specifications (AC) Over recommended operating conditions T All typicals ° Parameter Symbol Propagation Delay Time to t PLH High Output Level Propagation Delay Time to t PHL Low Output ...

Page 9

250 μ -60 -40 - 100 – TEMPERATURE – ° Figure 1. High level output current ...

Page 10

KΩ PLH L = 350 Ω PHL L 1 KΩ KΩ KΩ 40 ...

Page 11

... Figure 13. Input threshold current vs. temperature For product information and a complete list of distributors, please go to our website: Avago, Avago Technologies, and the A logo are trademarks of Avago Technologies in the United States and other countries. Data subject to change. Copyright © 2005-2010 Avago Technologies. All rights reserved. Obsoletes AV01-0208EN ...