bq50120etl16pys SynQor Worldwide Headquarters, bq50120etl16pys Datasheet - Page 4

no-image

bq50120etl16pys

Manufacturer Part Number
bq50120etl16pys
Description
Eighth-brick Dc Bus Converter
Manufacturer
SynQor Worldwide Headquarters
Datasheet
Product # BQ55120ETL16
T
T
ELECTRICAL CHARACTERISTICS (Continued)
Parameter
STANDARDS COMPLIANCE
Parameter
QUALIFICATION TESTING
Parameter
OPTIONS
SynQor provides various options for Logic Sense, Pin Length and
Feature Set for this family of DC/DC converters. Please consult
the last page of this specification sheet for information on avail-
able options.
echnical S
FEATURE CHARACTERISTICS
RELIABILITY CHARACTERISTICS
STANDARDS COMPLIANCE
QUALIFICATION TESTING
echnical S
Switching Frequency
ON/OFF Control (Option P)
ON/OFF Control (Option N)
ON/OFF Control (Either Option)
Over-Temperature Shutdown
Over-Temperature Shutdown Restart Hysteresis
Load Current Scale Factor
Calculated MTBF (Telcordia)
Calculated MTBF (MIL-217)
Field Demonstrated MTBF
UL/cUL 60950
EN60950
Needle Flame Test (IEC 695-2-2)
IEC 61000-4-2
GR-1089-CORE
• An external input fuse must always be used to meet these safety requirements. Contact SynQor for official safety
Life Test
Vibration
Mechanical Shock
Temperature Cycling
Power/Thermal Cycling
Design Marginality
Humidity
Solderability
• Extensive characterization testing of all SynQor products and manufacturing processes is performed to ensure that we
certificates on new releases or download from the SynQor website.
supply robust, reliable product. Contact the factory for official product family qualification documents.
Off-State Voltage
On-State Voltage
Off-State Voltage
On-State Voltage
Pull-Up Voltage
Pull-Up Resistance
72/23/EEC
93/68/EEC
P
P
pecification
pecification
Phone 1-888-567-9596
# Units
32
10
5
5
5
5
5
3
Notes
File # E194341, Basic insulation & pollution degree 2
Certified by TUV
Test on entire assembly; board & plastic components UL94V-0 compliant
ESD test, 8kV - NP, 15kV air - NP
Section 7 - electrical safety, Section 9 - bonding/grounding
Test Conditions
95% rated V
10-55Hz sweep, 0.060” total excursion,1 min./sweep, 120 sweeps for 3 axis
100g minimum, 2 drops in x and y axis, 1 drop in z axis
-40°C to 100°C, unit temp. ramp 15°C/min., 500 cycles
T
T
85°C, 85% RH, 1000 hours, 2 minutes on and 6 hours off
MIL-STD-883, method 2003
operating
min
-10°C to T
Min.
165
-1.0
-1.0
140
2.4
2.4
= min to max, V
www.synqor.com
in
max
and load, units at derating point, 1000 hours
+10°C, 5°C steps, V
1333
Typ.
2.81
0.91
190
10
30
10
PATENTS
SynQor is protected under various patents, including but not lim-
ited to U.S. Patent # 5,999,417; 6,222,742 B1; 6,594,159
B2; 6,545,890 B2.
in
= min to max, full load, 100 cycles
Max.
150
215
(Normal Performance)
0.8
0.8
18
18
Doc.# 005-2BE552B Rev. A
in
= min to max, 0-105% load
10
10
10
Units
kHz
kΩ
6
6
6
°C
°C
V
V
V
V
V
Hrs.
Hrs.
Hrs. See our website for details
Notes & Conditions
Figures A & B
Average PCB Temperature
See App Note: Output Load Current Calc.
TR-NWT-000332; 100% load,300LFM, 40 o C T a
MIL-HDBK-217F; 100% load, 300LFM, 40 o C T a
P
P
Current:
Current:
ackage:
ackage:
Output:
Output:
Input:
Input:
03/16/06
35-55 V
12 V
16 A
Eighth-brick
35-55 V
12 V
16 A
Eighth-brick
(192W)
(192W)
Page 4