provide enough headroom at its output to support a
+24 dBu input signal. The 1296 (configured for -6
dB gain) attenuates the input signal an additional
3 dB, compared to 1293. Although the noise floor of
1296 is 1.5 dB lower than 1293 noise floor, the
reduction in dynamic range is 3 dB - 1.5 dB =
Tel: +1 508 478 9200; Fax: +1 508 478 0990; Web: www.thatcorp.com
THAT Corporation; 45 Sumner Street; Milford, MA 01757-1656; USA
Copyright © 2008, THAT Corporation
Page 6 of 10
1.5 dB. The 1296 attenuates the input signal more
than necessary to support a +24 dBu input.
THAT recommends the -3 dB input configuration
possible only with the 1293 in order to preserve
dynamic range within a reasonable range of power
supply voltages and external headroom limits.
In fact, for most professional audio applications,
Low Cost Dual Balanced Line Receivers
THAT 1290 Series