3.3.2
Note:
*1. Input signal rise/fall time should be less than 12ns
*2. CL=100pF
URL:
Item
System cycle time
Address setup time
Address hold time
Data setup time
Data hold time
Output disable time (*2)
Access time (*2)
Enable High pulse width (Read)
Enable High pulse width (Write)
Enalbe Low pulse width (Read)
Enable Low pulse width (Write)
www.topwaydisplay.com
www.topwaysz.com
6800 Mode System Bus Timing
LCD Module User Manual
Symbol
tewhw
tewhr
tewlw
tcyc6
tacc6
taw6
tewlr
tah6
tds6
tdh6
toh6
MIN.
332
140
140
200
20
20
40
20
60
-
-
Document Name: LM6023B-Manual-Rev0.2.DOC
TYP.
-
-
-
-
-
-
-
-
-
-
-
V
SS
=0V, V
MAX.
100
140
-
-
-
-
-
-
-
-
-
DD
=5V, T
Page: 7 of 13
LM6023B
OP
Unit
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
=25°C