mpu-250s MicroPower Direct, LLC, mpu-250s Datasheet

no-image

mpu-250s

Manufacturer Part Number
mpu-250s
Description
Compact U-channel, 250w Power Factor Corrected, Ac/dc Power Supplies
Manufacturer
MicroPower Direct, LLC
Datasheet
MPU-250S
Key Features:
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
T: (781) 344-8226
F: (781) 344-8481
E: sales@micropowerdirect.com
W: www.micropowerdirect.com
Compact U-Channel, 250W
Power Factor Corrected,
AC/DC Power Supplies
250W Output Power
Universal 90-264 AC Input
Active PFC = >0.97
EN 60950 Approved
Low Leakage Current
Six Single Output Models
Meets EN 55022 B
>50 kHour MTBF
Only 7.0” x 4.2” x 1.6”
Electrical Specifi cations
Specifi cations typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifi cations subject to change without notice.
Parameter
Output Voltage/Current
Minimum Load
Output Voltage Tolerance
Line Regulation
Load Regulation
Ripple & Noise (20 MHz), See Note 2
Hold-Up Time
Temperature Coeffi cient
Short Circuit Protection
Over Voltage Protection
Overload Protection
Input
Parameter
Input Voltage Range
Input Frequency
Input Filter
Input Current
Inrush Current
Safety Ground Leakage Current
Power Factor Correction, See Note 1
Output
General
Parameter
Isolation Voltage
Isolation resistance
Isolation Capacitance
EMI/RFI
EMC Compliance
Switching Frequency
Environmental
Parameter
Operating Temperature Range
Storage Temperature Range
Cooling
Humidity
Physical
Size
Weight
Reliability Specifi cations
Parameter
MTBF
Safety Standards
Vibration
www.micropowerdirect.com
Series
Electrical Fast Transients/Bursts On Mains
10~500 Hz, 5G 10 min/1 Cycle. Period of 60 min each along X, Y &Z Axis
MIL HDBK 217F, 25°C, Gnd Benign
Electrostatic Discharge (ESD)
12, 15, 24, 48 VDC Output
Conditions
Conditions
Conditions
Conditions
Conditions
RF Field Susceptibility
RH, Non-condensing
Cold Start, 115 VAC
Cold Start, 230 VAC
Free Air Convection (See Derating Curve)
Iout = 5% to 100%
Meets EN 55022 Class B; FCC Class B
3.3, 5 VDC Output
Output to Ground
Vin = Min to Max
Input to Ground
Input to Output
UL 1950, EN 60950, IEC 60950
See Model Selection Guide
See Model Selection Guide
See Model Selection Guide
Continuous (Autorecovery)
7.0 x 4.2 x 1.6 Inches (177.8 x 106.68 x 40.64 mm)
Conducted
With Cover
See Note 3
U-Channel
Universal
500 VDC
264 VAC
115 VAC
230 VAC
115 VAC
Ambient
Surge
Fixed
3,000
1,500
Min.
Min.
Min.
Min.
Min.
0.97
0.93
120
130
500
-25
-40
0.0
90
47
18
50
IEC/EN 61000-4-2, -6, -8, -11
EN 55022; EN 61000-3-2, -3
±0.02
4,700
Typ.
Typ.
±2.0
±1.0
±1.0
Typ.
Typ.
Typ.
100
+25
67
Max.
Max.
Max.
Max.
Max.
40.0
80.0
IEC/EN 61000-4-3
IEC/EN 61000-4-4
IEC/EN 61000-4-5
264
370
100
150
+70
+85
26.1 Oz (0.750 kg)
28.6 Oz (0.823 kg)
3.5
63
95
1
mV P - P
kHours
mSec
Units
W/VA
Units
%/°C
Units
Units
Units
VDC
A Pk
VAC
VAC
kHz
M
mA
Hz
pF
°C
°C
%
%
%
%
%
%
%

Related parts for mpu-250s

mpu-250s Summary of contents

Page 1

... MPU-250S Compact U-Channel, 250W Power Factor Corrected, AC/DC Power Supplies Electrical Specifi cations Specifi cations typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifi cations subject to change without notice. Key Features: Input • 250W Output Power Parameter • ...

Page 2

... MPU-250S-48T(C) 4.0 2.0 For Cover option, add suffi x “C” to model number (i.e. MPU-250S-12TC) Notes: 1. PFC meets EN61000-3-2. 2. Ripple and noise is measured at 20 MHz bandwidth using a 0.1 µF and a 47 µF capacitor connected in parallel as close to the power supply terminals as possible. 3. Overload protection is provided by a “hiccup mode” circuit. The unit recovers automati- cally when the fault condition is removed ...