njg1602he3 New Japan Radio Co.,Ltd, njg1602he3 Datasheet - Page 3

no-image

njg1602he3

Manufacturer Part Number
njg1602he3
Description
Dpdt Switch Gaas Mmic
Manufacturer
New Japan Radio Co.,Ltd
Datasheet
Ver.2003-05-20
TERMINAL INFORMATION
No.
10
12
11
1
2
3
4
5
6
7
8
9
SYMBOL
GND
GND
GND
GND
GND
GND
VDD
CTL
P1
P2
P3
P4
Positive voltage supply terminal. The positive voltage (+2.5~+5.5V) have to be
supplied. Please connect a bypass capacitor with GND terminal for excellent
RF performance.
RF port. This port is connected with P4 port by controlling 12pin-CTL(H)
(+2.5~+VDD).
This port is connected with P2 port by controlling 12pin- CTL(L) (0~+0.8V) .
A DC cut capacitor 56pF is required at this terminal to block DC voltage of
inner circuit.
Ground terminal. Please connect this terminal with ground plane as close as
possible for excellent RF performance.
RF port. This port is connected with P3 port by controlling 12pin- CTL(L)
(0.2~+0.8V).
This port is connected with P3 port by controlling 12pin- CTL(H)(+2.5~+VDD).
A DC cut capacitor 56pF is required at this terminal to block DC voltage of
inner circuit.
Ground terminal. Please connect this terminal with ground plane as close as
possible for excellent RF performance.
RF port. This port is connected with P2 port by controlling 12pin- CTL(H)
This port is connected with P4 port by controlling 12pin-V
A DC cut capacitor 56pF is required at this terminal to block DC voltage of
inner circuit.
Ground terminal. Please connect this terminal with ground plane as close as
possible for excellent RF performance.
RF port. This port is connected with P1 port by controlling 12pin- CTL(H)
(+2.5~+VDD).
This port is connected with P3 port by controlling 12pin- CTL(L) (0~+0.8V).
A DC cut capacitor 56pF is required at this terminal to block DC voltage of
inner circuit.
Ground terminal. Please connect this terminal with ground plane as close as
possible for excellent RF performance.
Ground terminal. Please connect this terminal with ground plane as close as
possible for excellent RF performance.
Ground terminal. Please connect this terminal with ground plane as close as
possible for excellent RF performance.
Control signal input terminal.
This terminal is set to High-Level (+2.5V~VDD) or Low-Level (0~+0.8V).
(+2.5~+VDD).
DESCRIPTION
NJG1602HE3
CTL(L)
(0~+0.8V).
- 3 -