... Model Number Legend Note: This model number legend includes combinations that are not available. Before ordering, please check the List of Models on page 1 for availability. H3CR - Note: Specify the model number, supply voltage, and time range ( when ordering ...
Page 2
... Note the above minimum power ON time is not secured, the H3CR may not operate. Be sure to secure the above minimum power ON time not use the Timer with a repeat period of less than 3 s. Doing so may result in abnormal heating or burning. Refer to Safety Precautions (H3CR-H) on page 8 for details ...
Page 3
... EN61812-1 EN55011 Group 1 class A EN55011 Group 1 class A EN61812-1 IEC61000-4-2: IEC61000-4-4: IEC61000-4-5: H3CR contact discharge (level air discharge (level 3) IEC61000-4-3: 10 V/m (80 MHz to 1 GHz) (level (0. MHz) (level power-line (level I/O signal-line (level line to line (level 3) ...
Page 4
... Reference: A maximum current of 0.15 A can be switched at 125 VDC (cosφ and a maximum current of 0.1 A can be switched if L ms. In both cases, a life of 100,000 operations can be expected. The minimum applicable load VDC for H3CR-H8L/-HRL and 100 VDC for H3CR-H8RL (failure level: P). Time range/ ...
Page 5
... Without Reset Input (H3CR-H8L) Power supply 11-pin Model With Reset Input (H3CR-HRL) Reset input Power supply Note: Leave terminal 6 open. Do not use them as relay terminals. With Reset Input (H3CR-H8RL) Reset input Power supply Note: Leave terminal 3 open. Do not use them as relay terminals. H3CR-H 5 ...
Page 6
... Reset input OFF (Open) Output (8 − 6) Output (8 − 5) Lit Output indicator Not lit Rt ON Power (See note) OFF 0.05 s min. Reset input Output (1 − 3) Output (1 − 4) Output (11 − 9) Output (11 − 8) Lit Output indicator Not lit H3CR 0.05 s min 0.05 s min. 6 ...
Page 7
... Time unit display S-series: sec M-series: min dia 63 dia. Dimensions with Back Connecting Socket P3G-08/P3GA-11 92.9 15 86.4 H3CR-HRL 109.9 H3CR- H8@L P3G-08 Y92F-30 * P2CF-11 2.3 P2CF-11-E H3CR-H Time setting knob (for setting power OFF-delay time) 78.0 0.7 44.8 × 44.8 8 pins 78.0 0.7 44.8 × 44.8 11 pins 92.9 15 91.4 H3CR-HRL ...
Page 8
... Reset input Output required that the output be turned on repeatedly with an interval of shorter than 3 s, consider use of the H3CR-A in mode D (signal OFF-delay). ■ Others If the H3CR-H is dropped or experiences some other kind of shock, because a latching relay is used for output, contacts may be reversed or go into a neutral state ...
Page 9
... OMRON Corporation Industrial Automation Company http://www.ia.omron.com/ Read and Understand This Catalog Warranty and Limitations of Liability Application Considerations Disclaimers In the interest of product improvement, specifications are subject to change without notice. (c)Copyright OMRON Corporation 2010 All Right Reserved. 2010.7 ...