mpe-150s MicroPower Direct, LLC, mpe-150s Datasheet

no-image

mpe-150s

Manufacturer Part Number
mpe-150s
Description
Si L O Single Output, 150w 0 Compact, Enclosed Ac/dc Power Supplies
Manufacturer
MicroPower Direct, LLC
Datasheet
MPE-150S
Key Features:
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
T: (781) 344-8226
F: (781) 344-8481
E: sales@micropowerdirect.com
W: www.micropowerdirect.com
Single Output, 150W
Si
Compact, Enclosed
AC/DC Power Supplies
150W Output Power
Selectable 88-264 AC Input
EN 60950 Compliant
Eight Single Output Models
Meets EN55022
>285 kHour MTBF
Compact Metal Enclosure
RoHS Compliant
l O
Electrical Specifi cations
Specifi cations typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifi cations subject to change without notice.
Parameter
Output Voltage
Output Current
Output Voltage Adjustment
Output Voltage Tolerance, See Note 1
Ripple & Noise (20 MHz), See Note 2
Hold-Up Time
Set-Up Time
Rise Time
Temperature Coeffi cient
Short Circuit Protection
Over Voltage Protection
Overload Protection
Input
Parameter
Input Voltage Range
Input Frequency
Input Current
Inrush Current
Safety Ground Leakage Current
Output
General
Parameter
Isolation Voltage
Isolation resistance
EMI/RFI
EMC Compliance
Switching Frequency
Environmental
Parameter
Operating Temperature Range
Storage Temperature Range
Cooling
Humidity
Physical
Case Size
Case Material
Weight
Reliability Specifi cations
Parameter
MTBF
Safety Standards
Vibration
0
Electrical Fast Transients/Bursts On Mains
10~500 Hz, 2G 10 min/1 Cycle. Period of 60 min each along X, Y &Z Axis
MIL HDBK 217F, 25°C, Gnd Benign
Electrostatic Discharge (ESD)
Series
Conditions
Conditions
Conditions
Conditions
Conditions
RF Field Susceptibility
RH, Non-condensing
Free Air Convection (See Derating Curve)
Cold Start, 115 VAC
Cold Start, 230 VAC
Output to Ground
Switch Selectable
Input to Ground
Input to Output
7.83 x 4.33 x 1.97 Inches (199.0 x 110.0 x 50.0 mm)
Continuous (Autorecovery)
See Model Selection Guide
See Model Selection Guide
See Model Selection Guide
See Model Selection Guide
See Model Selection Guide
See Model Selection Guide
Conducted
See Note 3
See Note 4
IEN 60950, IEC 60950
Ambient
500 VDC
115 VAC
230 VAC
115 VAC
230 VAC
230 VAC
230 VAC
Surge
3,000
1,500
Min.
Min.
Min.
Min.
Min.
176
248
115
110
500
285
-10
-20
88
47
IEC/EN 61000-4-2, -6, -8, -11
EN 55022; EN 61000-3-2, -3
±0.02
17.0
35.0
Typ.
Typ.
Typ.
Typ.
Typ.
115
220
100
100
+25
20
28
50
25
Vented Metal Enclosure
Max.
Max.
Max.
Max.
Max.
132
264
370
135
160
+60
+85
1.5
3.5
63
IEC/EN 61000-4-4
IEC/EN 61000-4-5
95
IEC/EN61000-4-3
28.3 Oz (0.8 kg)
kHours
Units
Units
Units
Units
Units
mSec
mSec
mSec
%/°C
VDC
A Pk
VAC
VAC
kHz
mA
Hz
°C
°C
%

Related parts for mpe-150s

mpe-150s Summary of contents

Page 1

... MPE-150S Si Single Output, 150W l O Compact, Enclosed AC/DC Power Supplies Electrical Specifi cations Specifi cations typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifi cations subject to change without notice. Key Features: Input • 150W Output Power Parameter • ...

Page 2

... The unit must be repowered to recover once the fault condition is removed. 5. Effi ciency is measured with a 115 VAC input recommended that a fuse be used on the input of a power supply for protection. For the MPE-150S series, a 7.5A/250 VAC slow blow should be used. Pin Connections Pin ...

Related keywords