sge2648-1 Microsemi Corporation, sge2648-1 Datasheet

no-image

sge2648-1

Manufacturer Part Number
sge2648-1
Description
High Voltage Transformer For Ccfl Inverter Power Supply.
Manufacturer
Microsemi Corporation
Datasheet
This Document describes and specifies the electrical and mechanical characteristics of SGE2648-1 high voltage transformer
for CCFL inverter power supply. This component should be designed and manufactured in accordance with Engineering
Specification LES3811T
1. Electrical Characteristics
2. Winding Specifications
3. Physical Specification & Wiring Diagram
L1-2, L2-3 (uH)
L4-5 (mH)
L
(uH)
C4-5 (pF)
LKG2-4
Items
Secondary to Core
Primary to Core
Primary to Secondary
V4-5
,L
Winding Sequence
Wire Size & Type
Number of Turns
Winding Method
LKG4-6
Microsemi Integrated Products. 11861 Western Ave., Garden Grove, CA 92841 tel. (714) 898-8121
Should be shorted pin 4-5
24.5
890
2.0
243
Inductance ( at 100Khz, 1Vrms)
Min
Secondary Self Capacitance
Dielectric Voltage Withstand
Operating Test
Inductance ( at 10Khz, 0.1V)
60 Hz.,Arc-detect enabled, 5
sec. min., 200uA max.
leakage current
Primary driven with 60 kHz.
sine wave source (pin 1-3),
secondary measured with
Tektronix P6015 (or equiv.)..
Magnetic Component Specification
#34, Single Insulation,
1012
26.5
Nom
282
2.5
Pin 1 – 2
180°C
2S-1F
28
1210
28.5
329
Max
3.0
Primary
Bifilar
#34, Single Insulation,
R1-2, R2-3(mΩ)
Rdc4-5(Ω)
R1-2/R2-3
Balance of Primary DC resistance will be
HP4280A 1Mhz C meter, Floating mode
Items
used as Bifilar winding measure tool
Pin 2-3
180°C
3S-2F
28
2500Vrms min. ( 1min. 60Hz)
1000Vrms min.
1000Vrms min.
2000Vrms min.
0.96
420
405
Min
#46, Triple insulation,
D.C Resistance
Specification Number
Secondary
Nom
440
415
Pin 4-5
180°C
1
5S-4F
1700
Rev. B (073001)
SGE2648-1
1.04
460
430
Max