maavss0001 Tyco Electronics, maavss0001 Datasheet - Page 2

no-image

maavss0001

Manufacturer Part Number
maavss0001
Description
2.25 V Voltage Variable Absorptive Attenuator, 42 Db 1.8 - 2.5 Ghz
Manufacturer
Tyco Electronics
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MAAVSS0001
Manufacturer:
m/a-com
Quantity:
5 000
Part Number:
MAAVSS0001
Manufacturer:
MA/COM
Quantity:
20 000
Part Number:
maavss0001TR
Manufacturer:
MA/COM
Quantity:
5 000
Part Number:
maavss0001TR
Manufacturer:
MA/COM
Quantity:
20 000
Part Number:
maavss0001TR-3000
Manufacturer:
M/A-COM
Quantity:
5 000
2
M/A-COM Inc. and its affiliates reserve the right to make changes to the
product(s) or information contained herein without notice. M/A-COM makes
no warranty, representation or guarantee regarding the suitability of its
products for any particular purpose, nor does M/A-COM assume any liability
whatsoever arising out of the use or application of any product(s) or
information.
2.25 V Voltage Variable Absorptive Attenuator, 42 dB
1.8 - 2.5 GHz
Application Schematic
4. External DC blocking capacitors are required on all RF ports.
5. V
Electrical Specifications: T
Input Power for 1dB Change in Attenuation
RF IN/
RF IN/
RF IN/
RF IN/
OUT
OUT
OUT
OUT
CC
Input 3rd Order Intercept Point
= +3.3 V @ 50 µA typical. V
Maximum Attenuation
Attenuation Slope
100 pF
100 pF
Switching Speed
100 pF
100 pF
Insertion Loss
Parameter
Return Loss
Transients
CTL
= 0 V to +2.25 V @ 50 µA typical.
A
= 25°C, Frequency = 2.4 GHz, V
V
V
CC
CC
220 pF
220 pF
50% V
Test Conditions
0.75 V < V
0.75 V < V
1.75 V < V
0.75 V < V
0.75 V < V
0.0 V < V
15 pF
15 pF
V
V
V
CTL
CTL
CTL
CTL
V
V
CTL
= 3 V, In-Band
CTL
to 10% / 90% RF
= 2.25 V
= 0.5 V
CTL
CTL
CTL
CTL
CTL
CTL
< 0.75 V
< 1.75 V
< 1.75 V
< 2.25 V
< 2.25 V
< 2.25 V
Compliant
• North America Tel: 800.366.2266 / Fax: 978.366.2266
• Europe Tel: 44.1908.574.200 / Fax: 44.1908.574.300
• Asia/Pacific Tel: 81.44.844.8296 / Fax: 81.44.844.8298
Visit www.macom.com for additional data sheets and product information.
4,5
Handling Procedures
Please observe the following precautions to avoid
damage:
Static Sensitivity
Gallium Arsenide Integrated Circuits are sensitive
to electrostatic discharge (ESD) and can be
damaged by static electricity. Proper ESD control
techniques should be used when handling these
devices.
RoHS
Units
dB/V
dBm
dBm
mV
dB
dB
dB
dB
dB
nS
CC
= 3.3 V, Z
Min.
37
24
0
= 50 Ω
Typ.
100
MAAVSS0001
2.4
42
10
14
10
15
10
6
Max.
3.2
V3