ur7hcpxz-p440 Semtech Corporation, ur7hcpxz-p440 Datasheet - Page 6

no-image

ur7hcpxz-p440

Manufacturer Part Number
ur7hcpxz-p440
Description
Advanced Click-to-select No-drifttm Ps/2 Force Stick Controller
Manufacturer
Semtech Corporation
Datasheet
When the
is received, the UR7HCPXZ-P440
sets the following default
parameters: Incremental Stream
Mode, 1:1 scaling, report rate of
100 Hz, and disabled. It then
sends AAh to the host followed by
a device ID of 00h.
The host sends the Resend Last
Data Stream Command (FEh) when
it detects an error in any
UR7HCPXZ-P440 transmission.
The device then resends the last
output data packet to the host.
This transmission occurs after a
PixiPoint
before the host enables the
interface allowing the next
PixiPoint
The
Command (F6h)
device to its condition at power-up.
The
stops the device from transmitting
all reports. However, the mode
does not change; the PixiPoint
is still able to respond to
commands. If the Disable
Command is issued while the
device is transmitting a report, the
UR7HCPXZ-P440 immediately
stops the transmission and
disables itself.
Copyright Semtech 2000-2001
DOC7-PXZ-P440-DS-111
PS/2 MODE COMMANDS
Set Default Status
Disable Command (F5h)
TM
TM
Reset Command (FFh)
Z transmission and
Z output.
re-initializes the
TM
Z
The
(ECh)
previous mode, and disabled.
The
Command (F0h)
to Prompt Mode. Data values are
then only reported in response to a
Read Report Command (EBh)
If the
(EEh)
will immediately return any data
bytes except FFh or ECh.
If the PixiPoint
Stream Mode, the
Command (F4h)
begin data transmission. If the
device is in Prompt Mode, the
Enable Command will only update
the internal status of the PixiPoint
Z.
The PixiPoint
Set Sampling Rate Command
(F3h)
Modes but will only update its
internal status if this command is
enacted while the device is in the
Stream Mode.
The UR7HCPXZ-P440 responds to
the
(F2h)
6
Read Device Type Command
Reset Echo Mode Command
Set Prompt (Remote) Mode
Set Echo Mode Command
in both Stream and Prompt
with the device ID of 00h.
is received, the PixiPoint
returns the device to its
TM
TM
Z will respond to the
Z is in Incremental
sets the device
will allow it to
Enable
TM
.
Z
TM
The
(EBh)
a report. The report occurs even if
the device has not moved or if the
status of the switches did not
change.
The
Mode Command (EAh)
PixiPoint
disables the device.
The
(E9h)
report.
The
(E8h)
2:1 Scaling Command (E7h)
enables a coarse/fine tracking
response, and the
Command (E6h)
values of movements to be
transmitted to the host without any
scaling. Due to Semtech’s
Advanced Motion Algorithm, Set
Resolution and Scaling Commands
are acknowledged and reported as
activated, but their status is
ignored.
www.semtech.com
Read Report Command
Set Incremental Stream
Status Request Command
Set Resolution Command
returns a 3-byte status
controls resolution, the
prompts the PixiPoint
TM
Z to Stream Mode and
enables the
Set 1:1 Scaling
sets the
TM
Set
Z for

Related parts for ur7hcpxz-p440