ps-120-54p Mean Well Enterprises Co., Ltd., ps-120-54p Datasheet

no-image

ps-120-54p

Manufacturer Part Number
ps-120-54p
Description
120w Single Output Power Supply Or Battery Charger
Manufacturer
Mean Well Enterprises Co., Ltd.
Datasheet
SPECIFICATION
MODEL
OUTPUT
INPUT
PROTECTION
ENVIRONMENT
SAFETY &
EMC
(Note 4)
OTHERS
NOTE
S:Power Supply
A:Voltage detector
B:Current detector
P:With PFC
N:None PFC
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
RIPPLE & NOISE (max.)
VOLTAGE ADJ. RANGE
VOLTAGE TOLERANCE
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
OVERLOAD
OVER VOLTAGE
OVER TEMPERATURE
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMI CONDUCTION & RADIATION
HARMONIC CURRENT
EMS IMMUNITY
MTBF
DIMENSION
PACKING
120W Single Output Power Supply or Battery Charger
P A
Note.3
Note.2
120 P
7.2A
RTH2 70
13.8V
0 ~ 7.2A
99.36W
150mVp-p
12 ~ 15V
1.0% 6.0%
1000ms, 50ms at full load
16ms at full load
88 ~ 132VAC / 176 ~ 264VAC selected by switch
47~63Hz
>0.65 (with PFC series)
3A/115VAC
COLD START 25A/115VAC
<1.5mA / 240VAC
105 ~ 150% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
15 ~ 17V
Protection type : Hiccup mode, recovers automatically after fault condition is removed
Protection type : Hiccup mode, recovers automatically after fault condition is removed
-10 ~ +60
20 ~ 90% RH non-condensing
-20 ~ +85 , 10 ~ 95% RH
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
UL60950-1, TUV EN60950-1, EN60335, EN60335-1, EN60335-2-29 approved
I/P-O/P:3KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55022 (CISPR22) Class B
Compliance to EN61000-3-2,-3
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, light industry level, criteria A
249.5K hrs min.
PCB Type:144*90*33mm
1.1Kg; 16pcs / 17.9Kg / 1.47CUFT(without PFC)
PS-120-13P/C
77%/70%
3.0% 8.5%
1.0%
0.05%/
(0 ~ 45
(Refer to output load derating curve)
13 C
10
1.5A/230VAC
I/P-FG:1.5KVAC
MIL-HDBK-217F (25 )
detect on RTH2 thermistor
P:Open P.C.B.
C:With case
13:13.8V
27:27.6V
54:55.2V
External case type:180*96*49mm (L*W*H)
50A/230VAC
:O.D.M. number
O/P-FG:0.5KVAC
27.6V
4.3A
0 ~ 4.3A
118.68W
200mVp-p
24 ~ 30V
1.0% 5.0%
30 ~ 35V
PS-120-27P/C
81%/76%
1.0% 8.0%
1.0%
248 ~ 370VDC
1.24Kg; 16pcs / 20.1Kg / 1.47CUFT(with PFC)
P S - 1 2 0
54V
2.2A
0 ~ 2.2A
118.8W
250mVp-p
48 ~ 60V
1.0% 5.0%
PS-120-54P/C
82%/78%
60 ~ 66V
1.0% 7.5%
1.0%
TUV
Rheinland
Product Safety
geprUfre
Sicherheit
s e r i e s

Related parts for ps-120-54p

ps-120-54p Summary of contents

Page 1

... RTH2 thermistor (Refer to output load derating curve I/P-FG:1.5KVAC O/P-FG:0.5KVAC MIL-HDBK-217F (25 ) External case type:180*96*49mm (L*W*H) 1.24Kg; 16pcs / 20.1Kg / 1.47CUFT(with PFC TUV Rheinland geprUfre Sicherheit Product Safety PS-120-54P/C 54V 2. 2.2A 118.8W 250mVp 60V 1.0% 7.5% 1.0% 1.0% 5.0% 82%/78 66V ...

Page 2