h7cx-a11d1 Omron Corporation, h7cx-a11d1 Datasheet

no-image

h7cx-a11d1

Manufacturer Part Number
h7cx-a11d1
Description
Multifunction Preset Counter
Manufacturer
Omron Corporation
Datasheet
DIN 48 x 48 Multifunction Counter/Tachometer with a Bright, Easy-to-view Negative
Transmissive LCD. The H7CX Defines a New Standard.
• Highly visible display with backlit negative transmissive LCD.
• Easy to check the output status from a long distance with changing display colors
• Easy operation with a key for each digit.
• All basic settings can be made with the DIP switches.
• Includes preset counter, batch counter, dual counter, and tachometer.
• Compatible with a wide variety of inputs, such as NPN/PNP universal input and DC 2-wire Sensors.
• Certification: UL, CSA, and CE Marking.
• Complies with NEMA4 (equivalent to IP66) (when using the Y92S-29 Waterproof Packing).
*1: Not supported by the H7CX-A11@/-R11@.
*2: The functions that can be selected depend on the model.
Multifunction Counter/Tachometer (DIN 48 × 48)
H7CX Series
Multifunction Counter
Preset Counter
Total Counter
Batch Counter
Dual Counter
Tachometer
H7CX-A
Multifunction Counter
Tachometer
Common to All Models
H7CX-A............................................................
H7CX-R............................................................ 42
Safety Precautions ........................................... 59
Contents
H7CX Series
*2
*1
(red/green).
Refer to Safety Precautions on page 59.
2
Tachometer
H7CX-R
CSM_H7CX_DS_E_2_1
1

Related parts for h7cx-a11d1

h7cx-a11d1 Summary of contents

Page 1

... Multifunction Counter/Tachometer (DIN 48 × 48) H7CX Series DIN Multifunction Counter/Tachometer with a Bright, Easy-to-view Negative Transmissive LCD. The H7CX Defines a New Standard. • Highly visible display with backlit negative transmissive LCD. • Easy to check the output status from a long distance with changing display colors • ...

Page 2

... Multifunction Preset Counter H7CX-A DIN 48 × Multifunction Preset Counter with a Bright, Easy-to-view, Negative Transmissive LCD • Programmable PV color to visually alert when output status changes (screw terminal block models). • Configurable as 1-stage counter, 2-stage counter, total and pre- set counter, batch counter, dual counter, or tachometer. (Config- urability varies with model.) • ...

Page 3

... Sensor Output type Supply voltage power supply H7CX-A11@ 12 VDC Contact output 100 to 240 VAC H7CX-A11 VDC/ H7CX-A11D1 24 VAC Contact and 100 to 240 VAC --- transistor output VDC/ --- 24 VAC Transistor output 100 to 240 VAC H7CX-A11S ...

Page 4

... Minimum applied load VDC (failure level: P, reference value) Transistor output: NEMA B300 Pilot Duty, 1/4 HP 3-A resistive load at 120 VAC, 1/3 HP 3-A resistive load at 240 VAC External power supply 12 VDC (±10%), 100 mA (except for H7CX-A@D models) Refer to Safety Precautions (Common) on page 59 for details. Key protection Yes Prescaling function Yes (0 ...

Page 5

... Minimum applied load VDC (failure level: P, reference value) Transistor output: NEMA B300 Pilot Duty, 1/4 HP 3-A resistive load at 120 VAC, 1/3 HP 3-A resistive load at 240 VAC External power supply 12 VDC (±10%), 100 mA (except for H7CX-A@D models) Refer to Safety Precautions (Common) on page 59 for details. Key protection Yes Prescaling function Yes (0 ...

Page 6

... Weight Approx. 140 g Note meet UL listing requirements with the H7CX-A11@ models, an OMRON P2CF-11-@ or P3GA-11 Socket must be mounted on the H7CX. Otherwise, H7CX-A11@ models are considered to meet UL508 recognition requirements. 2. The Y92S-29 Waterproof Packing and Y92F-30 Flush Mounting Adapter are necessary to ensure IP66, NEMA4, and UL Type 4X water- proofing between the H7CX and installation panel ...

Page 7

... Reference: A current of 0.15 A max. can be switched at 125 VDC (cosφ=1) and current of 0.1 A max. can be switched if L/R=7 ms. In both cases, a life of 100,000 operations can be expected. The minimum applicable load VDC (failure level: P). ■ Inrush Current (Reference Values) Model Voltage H7CX-A11/-AW 100 to 240 VAC H7CX-A11D1/-AWD1 24 VAC/ VDC 26.4 VAC H7CX- VDC Inductive Load 1,000 700 500 ...

Page 8

... Internal control Input circuit circuit Note: All models except for H7CX-@D (models with 12 to 24-VDC power supplies) have basic insulation. ■ I/O Functions Using as a Counter Inputs CP1, CP2 • In general (except for dual counter mode) Reads counting signals Increment, decrement, command, individual, and quadrature inputs accepted. • ...

Page 9

... Unused Unused Unused OUT (−) (+) Note: Terminals 1 and 6 are connected internally. H7CX-A11S/-A114S/-A11SD1 1-stage Transistor Output Reset CP1 CP2 Internal circuit Total reset (− Sensor, etc VDC ...

Page 10

... Transistor Output (−) Sensor, etc. (+) 12 VDC OUT1 External power supply OUT2 (−) (+) H7CX-AUSD1 1 or 2-stage Transistor Output (−) Sensor, etc. (+) 12 VDC OUT1 or 2 External power supply OUT (−) ...

Page 11

... Input Connections The inputs of the H7CX are no-voltage (short-circuit or open) inputs or voltage inputs. When using as a tachometer, CP2 input and total reset/reset 2 input are not available. No-voltage Inputs (NPN Inputs) Open Collector Voltage Output Sensor PLC or sensor 0 V H7CX- ...

Page 12

... When the batch count value is displayed, resets the present value, the batch count value, and outputs. Dual counter Resets the CP1 present value, CP2 present val- ue, dual count value, and outputs. Tachometer Maintains the measured value and outputs (hold function). H7CX-A Operation Keys Switches ON Reset operation 12 ...

Page 13

... H7CX-ASD • H7CX-AWSD • H7CX-A4D • H7CX-A4SD 48×48 11-pin Socket Models (Flush Mounting/Surface Mounting) • H7CX-A11 • H7CX-A114 • H7CX-A11S • H7CX-A114S • H7CX-A11D1 • H7CX-A114D1 • H7CX-A11SD1 48×48 (Flush Mounting) 6 100 44.8×44.8 Note: M3.5 terminal screw (effective length: 6 mm) (Flush Mounting 44.8× ...

Page 14

... H7CX-A4WSD • H7CX-A4D • H7CX-A4SD 58 11-pin Socket Models (Adapter and Waterproof Packing Ordered Separately) • H7CX-A11 • H7CX-A114 • H7CX-A11S • H7CX-A114S • H7CX-A11D1 • H7CX-A114D1 • H7CX-A11SD1 58 ■ Dimensions with Front Connecting Socket H7CX -A11@ 109.7 112 P2CF-11 Note: These dimensions vary with the kind of DIN track (reference value). ...

Page 15

... Terminal Arrangement/ 35.4 Internal Connections Two, 4.5-dia. (Top View) holes 31.2 max. 5 4.5 7.8 3 1.2 35.4 Two, 4.5-dia. holes 30 31.2 max. Terminal Arrangement/ Internal Connections (Bottom View) 25.6 4.5 6.2 16.3 Twelve, 6.4-dia. holes 34 47.7 x 47.7 16.5 24.6 27.6 47.4 H7CX-A Surface Mounting Holes Two, 4.5 dia. or two, M4 40±0.2 Note: Track mounting is also possible ...

Page 16

... Waterproof Packing (provided with screw-terminal models) Y92S-29 When using the Y92S-29, the degree of protection for the H7CX's panel surface conforms to NEMA4, UL Type 4X, and IP66. (Depend- ing on the operating environment, the condition of the panel may deteriorate, shrink, or become harder. Therefore, regular replace- ment is recommended ...

Page 17

... Output mode ( K- • One-shot output time (except for 0.5 s and 0.05 s) (See note 2.) Note the time of delivery, the H7CX is set to the 1-stage counter (2-stage counter for H7CX-AW@/-A4W@ models) configuration. 2. Set to output 2 time when using as a 2-stage counter or batch counter. ...

Page 18

... For details on the setting methods, refer to page 19. When making settings using the operation keys, be sure to set pin 1 of the DIP switch to OFF. Switching to Total and Preset Counter, Batch Counter, and Dual Counter Operation (See note.) The H7CX is factory-set to the 1-stage counter (2-stage counter for H7CX-AW@/-A4W@ models) configuration. ...

Page 19

... Settings for All Functions Note: At the time of delivery, the H7CX is set to the 1-stage counter (2-stage counter for H7CX-AW@/-A4W@ models) configuration. When using as a 2-stage (or 1-stage) counter, total and preset counter, batch counter, or dual counter, switch to the configuration using the procedure given on page 36 ...

Page 20

... Red Note: When using as a 2-stage counter, this is the status of output 2. Output Allocation (otst) When using H7CX-AU@ models as a 2-stage counter, the output can be flexibly allocated to either stage Transistor output can be allocated to SV1 and contact output for SV2 or vice verse the following table. ...

Page 21

... When the key-protect switch is set to ON possible to prevent setting errors by prohibiting the use of certain operation keys by specifying the key protect level (KP-1 to KP-5). The key protect indicator is lit while the key-protect switch is set to ON. Confirm the ON/OFF status of the key- protect switch after the H7CX is mounted to the panel. (See note) ...

Page 22

... Set the dual count set value. When the dual count value reaches the dual count set value, signals are output according to the specified output mode. CP1/CP2 Present Value Show the present count values for CP1 and CP2 present values respectively. H7CX-A 22 ...

Page 23

... Minimum signal width: 16.7 ms (when maximum counting Counting starts when the CP1 is turned ON after turning ON the power. 4. The meaning of the H and L symbols in the tables is ex- plained below. Input method H7CX-A DOWN (Decrement) Mode A A Prohibit n−2 n−3 n−4 n− Prohibit n−1 n− ...

Page 24

... OUT1 OUT2 Note: 1. The full scale (FS) for H7CX 4-digit models is 9999. 2. When the present value reaches 999999, it returns Counting cannot be performed during reset/reset 1 input reset/reset 1 is input while one-shot output is ON, one-shot output turns OFF there is power failure while output is ON, output will turn ON again when the power supply has recovered. For one-shot output, output will turn ON again for the duration of the output time setting once the power supply has recovered ...

Page 25

... OUT1 OUT2 Note: 1. The full scale (FS) for H7CX 4-digit models is 9999. 2. When the present value reaches 999999, it returns Counting cannot be performed during reset/reset 1 input reset/reset 1 is input while one-shot output is ON, one-shot output turns OFF there is power failure while output is ON, output will turn ON again when the power supply has recovered. For one-shot output, output will turn ON again for the duration of the output time setting once the power supply has recovered ...

Page 26

... Applicable Counters K-2 mode: H7CX-A11@, H7CX-A@, and H7CX-AW@ D mode: H7CX-A11@, H7CX-A@, and H7CX-AW@ L mode: H7CX-A11@, H7CX-A@, and H7CX-AW@ H mode: H7CX-AW@ Reset/ Output K-2 reset 1 mode setting 999999 Set value 2 Set value 1 0 −99999 OUT1 OUT2 D Reset/ reset 1 999999 Set value 2 Set value 1 0 −99999 ...

Page 27

... Total count value 0 Note: The full scale (FS) for H7CX 4-digit models is 9999. Batch Counter Operation The H7CX has a batch counter, separate from the 1-stage preset counter, for counting the number of times the count has been completed. Reset 1 Reset 2 (batch counter reset) ...

Page 28

... Note: The above is for when the output mode is K-2. SUB mode can be used only when K- selected as the output mode with 6-digit models. H7CX-A • The operation after count com- pletion for the dual counter value is determined by the out- put mode. ...

Page 29

... Occurs when the present value reaches 999,999 (9,999 with 4-digit models) under the following conditions: • The output mode is K- • The H7CX is set for dual counter operation. 5. Includes the case where the EEPROM has reached its overwrite lifetime. Batch counter ...

Page 30

... Operating Procedures (Tachometer Function) Switching from Counter to Tachometer The H7CX is factory-set to the 2-stage counter (1-stage counter for H7CX-AU@ models) configuration. To switch to the tachometer configuration, use the procedure shown on the right. For details, refer to page 36. Settings for Basic Operations Settings for basic functions can be performed with just the DIP switch. ...

Page 31

... Note: Displayed for H7CX-AU@ models (KP-1) (KP-2) (KP-3) (KP-4) (KP-5) H7CX-A will not be displayed. 31 ...

Page 32

... Set the optimum number of times for the application. Auto-zero Time (aut possible to set the H7CX so that if there is no pulse for a certain time the display is force-set to 0. This time is called the auto-zero time. ...

Page 33

... When the key-protect switch is set to ON possible to prevent setting errors by prohibiting the use of certain operation keys by specifying the key protect level (KP-1 to KP-5). The key protect indicator is lit while the key-protect switch is set to ON. Confirm the ON/OFF status of the key- protect switch after the H7CX is mounted to the panel. (See note) ...

Page 34

... Output status Measurement value ≤ 999999 No change OFF Either press the reset key or reset the power supply. OFF Reset the power supply. OFF Reset to the factory settings using the reset key. H7CX-A Correction method Set value after reset No change No change No change 0 34 ...

Page 35

... OUT1 OUT2 ON condition for OUT1: Measurement value ≤ OUT1 set value ON condition for OUT2: Measurement value ≤ OUT2 set value H7CX-A OUT1 set value > OUT2 set value OUT2 set value ≤ measurement value ≤ OUT1 set value measurement value < OUT2 set value or measurement value > ...

Page 36

... Select which H7CX configuration is used (i.e., 1-stage counter, 2-stage counter, total and preset counter, batch counter, dual counter, or tachom- eter) in configuration selection mode. The H7CX is also equipped with a DIP switch monitor function, a convenient function that enables the settings of the DIP switch pins to be confirmed using the front display. ...

Page 37

... Dual counter Dual count value, dual count set value CP1 present value, CP2 present value keys ( key only with 6-digit models). H7CX-A Counting stopped Counting possible 3 s min. Function setting mode 3 s min. Input mode Dual count calculating mode ...

Page 38

... Run mode + min. Measurement value Measurement value, OUT1 set value Measurement value, OUT2 set value key. H7CX-A Counting stopped Counting possible 3 s min. Function setting mode 3 s min. Tachometer output mode Counting speed Decimal point position Prescale value Average processing ...

Page 39

... DIP switch dip on/off monitor Note: 1. The setting range varies with the model. 2. The default value for H7CX-AW@/-A4W@ models is 2cnt. Settings for Counter Operation Run Mode • 1-stage Counter Parameter name Parameter Present value, Present value ...

Page 40

... Setting range up/down/ud-a/ud-b/ud-c (See note 1.) add/sub (See note 1.) n/f/c/r/k-1/p/q/a/k-2/d/l/h (See note 2.) 0.01 to 99.99 0.01 to 99.99 hold/0.01 to 99.99 (See note 3.) 30h=/skh= 20ms/1ms ------/-----.-/----.--/---.--- (----/---.-/--.--/-.---) 0.001 to 99.999 (0.001 to 9.999) npn/pnp red/grn/r-g/g-r off/on kp-1/kp-2/kp-3/kp-4/kp-5 H7CX-A Default value Unit Set value --- --- 0 --- 0 --- --- 0 0 --- --- Default value Unit Set value ...

Page 41

... Display color colr red/grn/r-g/g-r Output allocation otst off/on Key protect level kypt kp-1/kp-2/kp-3/kp-4/kp-5 Parameter Setting range Default value 0 to 999999 999999 999999 999999 999999 0 Setting range H7CX-A Unit Set value --- --- --- --- --- --- --- --- Default value Unit Set value hilo --- --- 30h= --- ------ --- 1.000 off --- 99 ...

Page 42

... Tachometer H7CX-R DIN 48 × Socket-type Tachometer with a Bright, Easy-to-view, Backlit Negative Transmissive LCD • Socket design allows either flush or surface mounting. • Operation in any of the four following modes is possible with the same Unit: Upper and lower limit, upper limit, lower limit, and ar- ea. • ...

Page 43

... End Plate Spacer Note: Y92A-48G is a finger-safe terminal cover attached to the P3GA-11 Socket. Tachometer 11-pin socket H7CX-R11 H7CX-R11D1 Models Y92F-30 Y92S-29 P2CF-11 P2CF-11-E P3GA-11 P3GA-11 with Y92A-48G (See note.) Y92A-48 Y92A-48F1 PFP-50N PFP-100N PFP-100N2 PFP-M PFP-S H7CX-R 43 ...

Page 44

... Operating: −10 to 55°C (−10 to 50°C if tachometers are mounted side by side) (with no icing or conden- Ambient temperature sation) Storage: Ambient humidity 25% to 85% Case color Black (N1.5) Note: 1. Permissible ripple: 20% (p-p) max. 2. The display is lit only when the power is ON 250 VAC/30 VDC, resistive load (cosφ=1) −25 to 65°C (with no icing or condensation) H7CX-R 44 ...

Page 45

... Weight Approx. 140 g Note meet UL listing requirements with the H7CX-R11@ models, an OMRON P2CF-11-@ or P3GA-11 Socket must be mounted on the H7CX. Otherwise, H7CX-R11@ models are considered to meet UL508 recognition requirements. 2. The Y92S-29 Waterproof Packing and Y92F-30 Flush Mounting Adapter are necessary to ensure IP66, NEMA4, and UL Type 4X waterproofing between the H7CX and installation panel. ■ ...

Page 46

... Voltage Inputs (PNP Inputs) Approx. 4.7 kΩ Internal IN circuit Display circuit Key switch circuit Reads counting signals. Holds the measurement value and outputs. The hold indicator is lit during hold. Outputs signals according to the specified output mode when a comparison value is reached. OUT H7CX-R 46 ...

Page 47

... Input Connections The inputs of the H7CX-R can be used as either no-voltage (short-circuit or open) inputs or voltage inputs. They are set for use as voltage inputs at the time of delivery. No-voltage Inputs (NPN Inputs) Open Collector Voltage Output Sensor PLC or sensor 0 V Terminal Terminal ...

Page 48

... HLD 6th digit 1st digit H7CX-R Operation Keys Mode Key Used to switch mode and setting items. Hold Key Used to sustain the measurement value and output. Up Keys Switches Key Protect Switch (Factory setting) OFF ON (disable) (enable) ...

Page 49

... Note: These dimensions vary with the kind of DIN track (reference value). 14.4 6 72.5 44.8×44.8 Panel Y92F-30 (order separately) Flush Mounting Adapter P3GA-11 (order separately) Back Connecting (51) Socket 7.5 98.7 H7CX-R Panel Cutouts Panel cutouts are as shown below. (according to DIN43700). 60 min. +0.6 45 −0 +0.6 45 −0 60 min. 15 min. Note: 1. The mounting panel thickness should ...

Page 50

... Terminal Arrangement/ 35.4 Internal Connections Two, 4.5-dia. (Top View) holes 31.2 max. 5 4.5 7.8 3 1.2 35.4 Two, 4.5-dia. holes 30 31.2 max. Terminal Arrangement/ Internal Connections (Bottom View) 25.6 4.5 6.2 16.3 Twelve, 6.4-dia. holes 34 47.7 x 47.7 16.5 24.6 27.6 47.4 H7CX-R Surface Mounting Holes Two, 4.5 dia. or two, M4 40±0.2 Note: Track mounting is also possible ...

Page 51

... ON Pin 3 OFF 10 kHz ON OFF ON Pin 5 OFF ON PNP OFF ON H7CX-R Pin 4 Output mode OFF Upper and lower limit OFF Area ON Upper limit ON Lower limit Pin 6 Average processing OFF OFF (no average processing) OFF 2 times ON 4 times ON 8 times 51 ...

Page 52

... Set the value of each corresponding digit with the ∼ (0.1s) (999.9s) Set the value of each corresponding digit with the ∼ (0.0s) (99.9s) Set the key protect level with the key. (KP-1) (KP-2) (KP-3) (KP-4) H7CX-R key. (Three digits after decimal point) key. key. key. (KP-5) 52 ...

Page 53

... Auto-zero Time (aut=) For higher possible to set the H7CX-R so that if there is no pulse for a cer- tain time the display is force-set to 0. This time is called the auto-zero time. Note: Set the auto-zero time to a time slightly longer than the estimat- ed interval between input pulses and within the setting range (0 ...

Page 54

... When the key-protect switch is set to ON possible to prevent setting errors by prohibiting the use of certain operation keys by specifying the key protect level (KP-1 to KP-5). The key protect level is set in the function setting mode. The key protect indicator is lit while the key-protect switch is set to ON. Confirm the ON/OFF status of the key-protect switch after the H7CX is mounted to the panel. (See note) ...

Page 55

... Displays the currently measured value. Measurement value Comparison Value 1/Comparison Value 2 Comparison value 1 Set comparison value 1 and comparison value 2. The measurement value is compared to comparison value 1 and comparison value 2 and output is made according to the selected output mode. Measurement value Comparison value 2 H7CX-R 55 ...

Page 56

... ON condition: Measurement value ≥ Comparison value Measurement value Comparison value (Lower-limit) OUT ON condition: Measurement value ≤ Comparison value Operation Hold input (Hold Key) Actual input Display value Comparison value (Lower-limit) OUT H7CX-R Comparison value 1 > Comparison value 2 Sustained display value Sustained output 56 ...

Page 57

... Occurs when the measurement value reaches 999,999. 3. Display flashes (1-second cycles). ■ Operation in DIP Switch Monitor Mode The H7CX-R is also equipped with a DIP switch monitor function, a convenient function that enables the settings of the DIP switch pins to be con- firmed using the front display. Measurement stopped ...

Page 58

... Setting range H7CX-R Measurement stopped Measurement possible 3 s min. Function setting mode 3 s min. Decimal point position Prescale value Auto-zero time Startup time Key protect level Unit Set value --- ...

Page 59

... Not matching the content of the set values with the counted (or measured) items may cause unexpected operations resulting in injury or damage to the equipment. • Leaving the H7CX with outputs high temperature for a long time may hasten the degradation of internal parts (such as electrolytic capacitors). Therefore, use the product in combination with relays and avoid leaving the product as long as more than 1 month with the output turned ON ...

Page 60

... ON and OFF. • Be sure that the capacity of the power supply is large enough, otherwise the H7CX may not start due to inrush current (reference value: approx 1 26.4 VAC) that may flow for an instant when the H7CX is turned ON. ...

Page 61

... Input Impossible Possible Unstable Transistor Output The transistor output of the H7CX is isolated from the internal circuitry by a photocoupler, so the transistor output can be used as both NPN and PNP output. NPN output PNP output Load Load + Power for load ...

Page 62

... Safety Precautions (H7CX-R) ■ Precautions for Safe Use Changing the Measurement Value The H7CX-R uses a constant read-in system, so the output status is affected when the comparison values are changed during operation such that the present measurement value falls within the range of the upper- and lower-limit comparison values ...

Page 63

... OMRON Corporation Industrial Automation Company http://www.ia.omron.com/ Read and Understand This Catalog Warranty and Limitations of Liability Application Considerations Disclaimers In the interest of product improvement, specifications are subject to change without notice. (c)Copyright OMRON Corporation 2008 All Right Reserved. 2008.12 ...