e5ek-tprr2ac100-240 Omron Corporation, e5ek-tprr2ac100-240 Datasheet

no-image

e5ek-tprr2ac100-240

Manufacturer Part Number
e5ek-tprr2ac100-240
Description
Digital Controller E5ek
Manufacturer
Omron Corporation
Datasheet
Advanced Digital Controllers Ideal for
Worldwide Use
• Modular structure
• High-accuracy: 100 ms sampling (for analog input)
• Auto-tuning and fuzzy self-tuning
• Conforms to international EMC and safety standards.
• IP66/NEMA4 (indoor use) front face
• Remote set point
• Serial communications (RS-232C, RS-422 and RS-485) and
• Position-proportional control model
• Heating/cooling control
Model Number Structure
■ Model Number Legend
1. Model
2. Number of alarms
E5EK- @@@ @ -500
transfer output (4 to 20 mA)
Digital Controller
E5EK
AA:
PRR: Position-proportional model
T:
2:
Refer to Safety Precautions for All Temperature Controllers.
Standard model
Programmable type
Two alarms
1
2
Refer to E5
procedures.
@
K Operation for operating
CSM_E5EK_DS_E_3_1
1

Related parts for e5ek-tprr2ac100-240

e5ek-tprr2ac100-240 Summary of contents

Page 1

... Serial communications (RS-232C, RS-422 and RS-485) and transfer output ( mA) • Position-proportional control model • Heating/cooling control Refer to Safety Precautions for All Temperature Controllers. Model Number Structure ■ Model Number Legend E5EK- @@@ @ -500 Model AA: Standard model PRR: Position-proportional model ...

Page 2

... E53-EN01 E53-EN02 E53-EN03 E53-AKF Note: 1. The Option Unit can be used either by the E5AK or E5EK. 2. The E5AK allows a maximum of three Option Units to be mounted. The E5EK allows only one Option Unit to be mounted. Inspection Report The Digital Controller can be provided together with an inspection report. ...

Page 3

... Note: Do not use the output from an inverter as the power supply. Refer to Safety Precautions for All Temperature Controllers. *1.All control outputs are isolated electrically from the input circuits. *2.The E5EK-AA2-DRT, E5EK-T, and E5EK-TP do not support fuzzy self-tuning. ■ Input Ranges Platinum Resistance Thermometer ...

Page 4

... Voltage input E5EK −200 100 1,700 1,700 1,800 2,300 1,300 −300 300 ...

Page 5

... Front panel: NEMA4 for indoor use (equivalent to IP66) Rear case: Terminals: Memory protection Non-volatile memory (number of writings: 100,000 operations) Weight E5AK: approx. 450 g E5EK: approx. 320 g Mounting bracket: approx EMC Emission Enclosure: Emission AC Mains: Immunity ESD: Immunity RF-interference: Immunity Conducted Disturbance: ENV50141: ...

Page 6

... Synchronization method: Start-stop synchronization (asynchronous method) RS-422 Baud rate: 1.2/2.4/4.8/9.6/19.2 kbps RS-485 Transmission code: ASCII mA: Permissible load impedance: 600 Ω max. Resolution: approx. 2,600 2 (10G) Single-phase 50 A VAC (See note 1.) ±5% FS±1 digit max. 0.1 to 49.9 A (in units of 0.1 A) (See note 2.) 190 ms (See note 3.) E5EK Specifications 6 ...

Page 7

... Terminal Cover E53-COV0809 No. 1 display No. 2 display A/M Key Up Key/Down Key 120 min. Note: 1. Recommended panel thickness mm. 2. Maintain the specified vertical and horizontal E5EK Panel Cutouts 60 min. mounting space between each Unit. Units must not be closely mounted vertically or horizontally. E53-COV08 7 ...

Page 8

... Be sure to confirm this point at your site. Consider one year a rough standard. OMRON shall not be liable for the level of water resistance if the customer does not perform periodic replacement.) The Waterproof Packing does not need to be attached if a waterproof structure is not required. E5EK 2.36 dia. 12 dia. 40 × 40 ...

Page 9

... OMRON Corporation Industrial Automation Company http://www.ia.omron.com/ Read and Understand This Catalog Warranty and Limitations of Liability Application Considerations Disclaimers In the interest of product improvement, specifications are subject to change without notice. (c)Copyright OMRON Corporation 2009 All Right Reserved. 2009.4 ...

Related keywords