gnt200 SL Power Electronics, gnt200 Datasheet

no-image

gnt200

Manufacturer Part Number
gnt200
Description
Gnt200 Front End Series 200 Watt Ac/dc
Manufacturer
SL Power Electronics
Datasheet
AC Input
100-240VAC, 50/60 Hz, single phase. 80-270VAC, 45-65 Hz max.
Input Current
120VAC, 3 A. 230VAC, 1.5 A.
Inrush Current
Limited by internal thermistor. The inrush at 240VAC, averaged over the first
AC half-cycle under cold start conditions will not exceed 38A.
Input Fuses
F1 and F2, T4A/250V.
Power Factor
0.98 typical, 0.96 minimum.
Earth Leakage Current
100 uA at 120VAC NC, 400 uA at 264VAC SFC.
Output Power
200 W continuous with 200 lfm airflow. See chart for convection ratings.
Peak Output Power
240 W for 1 minute, 10% duty cycle.
Output Voltage
See chart.
Voltage Adjustability
Adjustable potentiometer capable of ±5% change from nominal setting.
Minimum Load
Not required.
Total Regulation
See chart.
Transient Response
500 μs to 1%, 50% load step, ∆i/∆t<0.2 A/μs.
Maximum voltage deviation is 3.5%.
• Wide Range Input 100-240 VAC with PFC
• Inhibit, Enable, Power Signals and Remote Sense Standard
• Power Density 10-13W/in3
• Compact (3.0” x 5.0” x 1.25”)
• High Efficiency 90% Typical
• Main Output and Two Aux Outputs
• Conducted EMI Class B
• Approved to CSA/EN/IEC/UL 60950-1 for ITE
• Approved to EN/IEC/UL 60601-1 and CSA22.2
• Also Available in Class II (G2T200)
• CB Report Available (for IEC60601-1 Standard)
SL Power Electronics Corp.
No. 601.1 for Medical
GNT200
Front End Series 200 Watt AC/DC
Universal Input Power Supply
International Safety Standard Approvals
Specifications
6050 King Drive
Ventura, CA 93003
All specifications are typical at nominal input, full load at 25°C unless otherwise stated
Phone:805.486.4565
Turn On Time
500 ms max.
Hold-up Time
20 ms at 200 W.
Over/Undershoot
3.5% max.
Overload Protection
Cycling type, 250 W nominal limit.
Overvoltage Protection
See chart.
Ripple and Noise
1% pk-pk max., 20 MHz BW, 0.1 μF and 10 μF caps on probe.
ITE Safety Standards
CSA/EN/IEC/UL 60950-1.
Medical Safety Standards
EN/IEC/UL 60601-1, CSA 22.2 No. 601.1.
Thermal Considerations
Keeping the following components below these temperatures indicates
amount of cooling is sufficient: Q1: 90°C max, T4: 110°C max.
Switching Frequency
Output 195 kHz +/-12 kHz, PFC 130 kHz.
MTBF
300K hours per Telcordia.
Overtemperature Protection
Automatic.
Efficiency
90% typical at 230VAC, 87% typical at 120VAC.
2 Year Warranty
Fax:805.487.8911
Email:info@slpower.com
www.slpower.com