MDC_UCE MURATA [Murata Manufacturing Co., Ltd.], MDC_UCE Datasheet
MDC_UCE
Related parts for MDC_UCE
MDC_UCE Summary of contents
Page 1
... BASIC I/O insulation provides input/output isolation to 2250V. Radiation emission testing is performed to widely-accepted EMC standards. INPUT UNDERVOLTAGE, INPUT OVERVOLTAGE, AND OUTPUT OVERVOLTAGE COMPARATORS REFERENCE & ERROR AMP Typical topology is shown. Technical enquiries email: sales@murata-ps.com, tel: MDC_UCE.A18 Page +SENSE (7) +V OUT (8) −V OUT (4) −SENSE ...
Page 2
... L2 = Pin length 0.145 inches (3.68mm)* * Special quantity order is required. , standard , optional, special quantity order Note: Some model combinations may not be available. Contact Murata Power Solutions for availability. Technical enquiries email: sales@murata-ps.com, tel: MDC_UCE.A18 Page Package Typ. Case Pinout 87% C56 P32 88% ...
Page 3
... See ordering guide Isolation Isolation Resistance Capacitance MΩ pF Isolation Safety Rating 100 10 1000 Basic Insulation 100 Technical enquiries email: sales@murata-ps.com, tel: MDC_UCE.A18 Page “N” Model Suffix OFF=open or +2.5V to +15V max. +0.8V max. Current Limit Inception 98% of Vout, after warmup A 24.5 36 ...
Page 4
... Amps, 10 sec. max. Magnetic feedback. See specifi cations. Current-limited. Devices can withstand sustained short circuit without damage. –40 to +125°C. See soldering guidelines. Technical enquiries email: sales@murata-ps.com, tel: MDC_UCE.A18 Page Relative Humidity 16 (non-condensing) to +85°C/85% +1 508 339 3000 ...
Page 5
... FCC part 15, class B, EN55022 Designed to meet UL/cUL 60950-1, CSA-C22.2 No. 60950-1, IEC/EN 60950-1 www.murata-ps.com UCE Series Isolated, High-Density, Eighth-Brick 100W DC/DC Converters input. Use approximately IN Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000 MDC_UCE.A18 Page ...
Page 6
... However all units are plug-compatible. INPUT/OUTPUT CONNECTIONS Pin Function P32 1 −Input 2 On/Off Control 3 +Input 4 −Output 5 −Sense 6 Output Trim 7 +Sense 8 +Output Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000 MDC_UCE.A18 Page ...
Page 7
... CURRENT PROBE 4 +INPUT L BUS + – BUS IN + – 1 −INPUT = 33μF, ESR < 700mΩ @ 100kHz IN = 220μF, ESR < 100mΩ @ 100kHz BUS = 12μH BUS Figure 2. Measuring Input Ripple Current Technical enquiries email: sales@murata-ps.com, tel: MDC_UCE.A18 Page 508 339 3000 ...
Page 8
... If the output voltage drops too low (approxi- mately 98% of nominal output voltage for most models), the magnetically www.murata-ps.com UCE Series Isolated, High-Density, Eighth-Brick 100W DC/DC Converters Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000 MDC_UCE.A18 Page ...
Page 9
... Sense Current 7 ON/OFF TRIM CONTROL Sense Return 8 SENSE − I Return OUT 9 +INPUT -OUTPUT Contact and PCB resistance losses due to IR drops Figure 4. Remote Sense Circuit Confi guration Technical enquiries email: sales@murata-ps.com, tel: MDC_UCE.A18 Page LOAD +1 508 339 3000 ...
Page 10
... ON/OFF CONTROL 1 -INPUT Figure 7. Driving the On/Off Control Pin (suggested circuit) +OUTPUT –INPUT +SENSE R TRIM DOWN ON/OFF TRIM CONTROL –SENSE +INPUT –OUTPUT Figure 8. Trim Connections To Decrease Output Voltages Technical enquiries email: sales@murata-ps.com, tel: MDC_UCE.A18 Page LOAD +1 508 339 3000 ...
Page 11
... Also, capacitors with higher ESR may use a larger capacitance. www.murata-ps.com UCE Series Isolated, High-Density, Eighth-Brick 100W DC/DC Converters Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000 MDC_UCE.A18 Page ...
Page 12
... LFM 300 LFM 200 LFM 100 LFM Ambient Temperature (ºC) 300 LFM 200 LFM 100 LFM Natural Convection Ambient Temperature (ºC) Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000 MDC_UCE.A18 Page ...
Page 13
... LFM 300 LFM 200 LFM 100 LFM Ambient Temperature (ºC) 400 LFM 300 LFM 200 LFM 100 LFM Ambient Temperature (ºC) Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000 MDC_UCE.A18 Page ...
Page 14
... LFM 400 LFM Ambient Temperature (ºC) Natural Convection 100 LFM 200 LFM 300 LFM 400 LFM Ambient Temperature (ºC) Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000 MDC_UCE.A18 Page ...
Page 15
... Ambient Temperature (ºC) 400 LFM 300 LFM 200 LFM 100 LFM Ambient Temperature (ºC) 400 LFM 300 LFM 200 LFM 100 LFM Ambient Temperature (ºC) +1 508 339 3000 MDC_UCE.A18 Page ...
Page 16
... Osaka, Tel: 6-6354-2025, email: sales_osaka@murata-ps.com Shanghai, Tel: +86 215 027 3678, email: shanghai@murata-ps.com Guangzhou, Tel: +86 208 221 8066, email: guangzhou@murata-ps.com Parkway Centre, Tel: +65 6348 9096, email: singapore@murata-ps.com Technical enquiries email: sales@murata-ps.com, tel: MDC_UCE.A18 Page 508 339 3000 ...