HVP100 HITRON [HITRON ELECTRONICS CORPORTION], HVP100 Datasheet

no-image

HVP100

Manufacturer Part Number
HVP100
Description
UNIVERSAL INPUT HARMONIC CORRECTION AC-DC OPEN FRAME SINGLE & MULTI-OUTPUT 100 WATTS INTERNAL SWITCHING POWER SUPPLIES
Manufacturer
HITRON [HITRON ELECTRONICS CORPORTION]
Datasheet
H HiTRON
UNIVERSAL INPUT HARMONIC CORRECTION
AC-DC OPEN FRAME SINGLE & MULTI-OUTPUT 100 WATTS
INTERNAL SWITCHING POWER SUPPLIES HVP100 SERIES
SPECIFICATION
INPUT SPECIFICATION
Input Voltage: Typ. 90-264Vac with PFC.
Input Connector: B-S connector.
Input Frequency: 47-63Hz.
Inrush Current: Typ. 20A @230Vac (active).
Input Current: 1.6A@115Vac, 0.6A@230Vac.
Dielectric Withstand: Meet IEC 60950-1.
EMI: Meet CISPR PUB. 22 Class B.
Hold-up Time: Typ. 30mS @ 115Vac & 230Vac.
Power Fail Signal: Installed.
Power Factor Correction: Meet Harmonic Correction
Earth Leakage: Less than 0.5mA.
GENERAL SPECIFICATION
Efficiency: Typ. 74-79%.
Switching Frequency: Fixed frequency at 85 or 80K Hz.
Circuit Topology: PWM fixed frequency forward circuit.
Transient Response: Output voltage returns in
Safety Standard: UL 60950-1/EN 60950-1 Class I.
Note: Due to requests in market and advances in technology, specifications subject to change without notification.
less than 3mS following
a 25% load change.
per IEC 61000-3-2.PF typ. 0.98.
-43-
FEATURES:
OUTPUT SPECIFICATION
Output Voltage: See Ratings Chart.
Output Current: See Ratings Chart.
Output Connector: B-S connector.
Output Wattage: Typ. 100 Watts.
Line Regulation: Typ. 1.0%.
Load Regulation: Main VO1 typ. ±1.0%.
Noise & Ripple: Typ. 1.0% peak to peak.
OVP: Built-in at main VO1 only.
Remote Sense: Installed in VO1.
Adjustability: Available at main O/P VO1.
Overload Protection (OLP):
Operating Temperature: 0 to +50°C.
Storage Temperature: -20 to +85°C.
Temperature Coefficient: Typ. 0.04% /°C.
Cooling: Free air convection.
Construction: Enclosure box or L-bracket format.
Power Density: 2.16Watts / Cubic Inch.
Fully protected against output overload and short circuit.
OLP set at about 125-150% rating output wattage.
Consult the factory for OLP setting.
ACCOMMODATE UNIVERSAL AC SOURCES
MEET IEC 61000-3-2 HARMONIC CORRECTION
MEET UNIVERSAL SAFETY STANDARDS
EMI MEET CISPR PUB. 22 CLASS B
CE MARKING COMPLIANCE
Recommended 20cfm fan cooling for full load.
For the details of safety approval, please consult the factory.

Related parts for HVP100

HVP100 Summary of contents

Page 1

... H HiTRON UNIVERSAL INPUT HARMONIC CORRECTION AC-DC OPEN FRAME SINGLE & MULTI-OUTPUT 100 WATTS INTERNAL SWITCHING POWER SUPPLIES HVP100 SERIES SPECIFICATION INPUT SPECIFICATION Input Voltage: Typ. 90-264Vac with PFC. Input Connector: B-S connector. Input Frequency: 47-63Hz. Inrush Current: Typ. 20A @230Vac (active). Input Current: 1.6A@115Vac, 0.6A@230Vac. ...

Page 2

... Coupled choke. " " Installed with Post Regulator (P.R.). "†" Stacked on main output. MECHANICAL DIMENSIONS: INPUT & OUTPUT CONNECTORS PIN ASSIGNMENT AC INPUT ASSIGNMENT AC-L AC-N AC-G CNTR & PIN # P1-1 P1-2 P1-3 P1-4,5 Mating connector: P1: Non, Screw on Top. P2: Molex 5051 or equivalent. DUAL OUTPUT MODEL NO. Volt. HVP100- 21 5.0V HVP100- 22 12.0V HVP100- 23 15.0V HVP100- 291 24.0V HVP100- 292 28.0V HVP100- 293 36.0V 48.0V 3.3V AUX. VO2 †■ Volt. Typ. ...