S80830 SII [Seiko Instruments Inc], S80830 Datasheet - Page 24

no-image

S80830

Manufacturer Part Number
S80830
Description
ULTRA-SMALL PACKAGE HIGH-PRECISION VOLTAGE DETECTOR
Manufacturer
SII [Seiko Instruments Inc]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
S80830ALY
Manufacturer:
SEIKO
Quantity:
19 802
Part Number:
S80830CLY
Manufacturer:
SEIKO
Quantity:
9 660
Part Number:
S80830CNY
Manufacturer:
SEIKO
Quantity:
18 872
*1. −V
*2. Specified detection voltage value (−V
*3. The temperature change ratio in the detection voltage [mV/°C] is calculated by using the following equation.
24
Detection voltage
Release voltage
Current consumption
Operating voltage
Output current
Leakage current
Response time
Detection voltage
temperature
coefficient
ULTRA-SMALL PACKAGE HIGH-PRECISION VOLTAGE DETECTOR
S-808xxC Series
Electrical Characteristics for Customized Products
1. S-80824KNUA-D2B-T2, S-80824KNY-x
DET
*1. Temperature change ratio of the detection voltage
*2. Specified detection voltage
*3. Detection voltage temperature coefficient
Item
: Actual detection voltage value
*3
Ta
V
DET
*1
[
mV/
°
C
]
Ta
*1
Symbol
−V
+V
I
=
I
V
t
LEAK
I
OUT
PLH
SS
V
DD
DET
DET
DET
V
V
DET(S)
DET
Output transistor,
Nch, V
Output transistor,
Nch, V
(
Typ.
DET(S)
) [ ]
Ta=−40°C to 85°C
DS
DD
V
Seiko Instruments Inc.
)
=0.5 V
=10.0 V, V
2 *
V
Condition
×
DD
=6.0 V
Table 18
Ta
V
V
DS
V
DET
DD
V
=10.0 V
DD
DET
=0.95 V
=1.2 V
[
ppm/
°
C
2.295
4.300
0.95
0.03
0.23
Min.
]
3 *
÷
(Ta=25°C unless otherwise specified)
1000
2.400
4.400
±100
Typ.
0.24
0.50
0.8
*2
2.505
4.500
±350
Max.
10.0
2.4
0.1
60
ppm/°C
Rev.3.2
Unit
mA
µA
µA
µs
V
V
circuit
Test
_00
1
2
1
3
1

Related parts for S80830