Page 1
... UL 60950 recognized, TUV EN60950 and CSA C22.2 No. 60950-00 Certified • Meets conducted limits of FCC Class B and CEI IEC61204-3 Class B with external filter • MTBF of 850,000 hours @ 50°C (MIL-HDBK-217F) 1719 S. Grand Avenue, Santa Ana, CA 92705 U.S.A. 48Vin 2.5Vout 7.0A input-to-output isolation PS S25-48-2.5 Rev 3 16-1-04 Inc. 3 ...
Page 2
... LFM Free Air 200 LFM 7.0 6.5 7.0 1719 S. Grand Avenue, Santa Ana, CA 92705 U.S.A. BTCPower BTCPower Output Voltage Current Full load (Volts) (Amps) 0.475 2.5 7.0 Output Current at 80°C (Amps) 300 LFM Free Air 200 LFM 7.0 3.8 PS S25-48-2.5 Rev 3 16-1- Efficiency 75% Load (%) 87 300 LFM 4.9 5 ...
Page 3
... S25-48-2.5 Rev 3 16-1- UNIT %Vo % VDC VDC VDC M pF KHz ...
Page 4
... There are two ON/OFF control options: positive logic (S25-48-2.5) and negative logic (S25- 48-2.5N). Both are referenced to Vin-. Pin 1 is the "Enable" pin, connecting a TTL compatible pin. A TTL control signal to this pin, according to the specification, turns the unit on or off ...
Page 5
... Trim Resistor The OVP set point is around 100 C. 0.13k -9% 0.38k -8% 1..34k -7% 2.55k -6% 4.04k -5% 6.14k -4% 9.17k -3% 14.40k -2% 24.69k -1% 56.85k 1719 S. Grand Avenue, Santa Ana, CA 92705 U.S.A. BTCPower BTCPower S25-48-2.5 Rev 3 16-1-04 ...
Page 6
... Fig 6. Conducted EMC (150KHz-30MHz) test result, the upper trace is the limit of EN55022 Class B specification Input Transient Withstand (ITW) The unit can withstand input transient voltage with 100V/100ms pulse and never be damaged 1719 S. Grand Avenue, Santa Ana, CA 92705 U.S.A. BTCPower BTCPower T M emission meets the . S25-48-2.5 Rev 3 16-1-04 ...
Page 7
... C with the airflow of 0, 100 and 200LFM (0, 0.5m/s and 1m/s). Others Other curve and waveforms presented include the output voltage vs. current curve (Fig 16) and the input current ripple waveform at full load condition (Fig 17) 1719 S. Grand Avenue, Santa Ana, CA 92705 U.S.A. BTCPower BTCPower S25-48-2.5 Rev 3 16-1-04 ...
Page 8
... For this example, the unit total start up time (t3- t1) is typically 300us. Broadband TelCom Power, Inc. – Tel.: 714-259-4888 • Fax: 714-259-0840 • www.btcpower.com • Email: sales@btcpower.com 48Vin 2.5Vout 7A Fig 8. Start up using On/Off pin 1719 S. Grand Avenue, Santa Ana, CA 92705 U.S.A. BTCPower BTCPower Fig 7. Start up waveform S25-48-2.5 Rev 3 16-1- ...
Page 9
... Fig 12. Efficiency at nominal input (48V) vs. load at different ambient temperatures without air flow, the input voltage is 48V. 1719 S. Grand Avenue, Santa Ana, CA 92705 U.S.A. BTCPower BTCPower T M 36V 48V 75V 2.8 4.2 5.6 7 Output current (A) 25°C 40°C 55°C 2.8 4.2 5.6 7 Output current ( S25-48-2.5 Rev 3 16-1-04 ...
Page 10
... Over Current Protection Curve Fig 16. Output voltage vs current showing current limit point and converter shut down point 1719 S. Grand Avenue, Santa Ana, CA 92705 U.S.A. BTCPower BTCPower 0LFM 100FM 200LFM Line Ambient Temperature(° S25-48-2.5 Rev 3 16-1- ...
Page 11
... Fig 17. Input current ripple with full output load at 48V input (50mA/div), time scale: 1 s/div Broadband TelCom Power, Inc. – Tel.: 714-259-4888 • Fax: 714-259-0840 • www.btcpower.com • Email: sales@btcpower.com 48Vin 2.5Vout 7A 1719 S. Grand Avenue, Santa Ana, CA 92705 U.S.A. BTCPower BTCPower S25-48-2.5 Rev 3 16-1-04 ...