RLS LITTELFUSE [Littelfuse], RLS Datasheet

no-image

RLS

Manufacturer Part Number
RLS
Description
RLN/RLS Class H Fuses
Manufacturer
LITTELFUSE [Littelfuse]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
RLS-71 TE-11
Quantity:
2 500
Part Number:
RLS-71TE-11
Manufacturer:
NEC
Quantity:
2 528
Part Number:
RLS-71TE-11
Manufacturer:
ROHM/罗姆
Quantity:
20 000
Part Number:
RLS-73
Manufacturer:
ROHM/罗姆
Quantity:
20 000
Part Number:
RLS-73 TE-12
Manufacturer:
JEL
Quantity:
119
Part Number:
RLS-73TE-11
Manufacturer:
ROHM
Quantity:
2 937
Part Number:
RLS-73TE-11
Manufacturer:
ROHM/罗姆
Quantity:
20 000
Part Number:
RLS-92
Manufacturer:
ROHM
Quantity:
37 000
Part Number:
RLS-92
Manufacturer:
ROHM/罗姆
Quantity:
20 000
Part Number:
RLS244
Manufacturer:
ST
0
Part Number:
RLS245
Manufacturer:
ST
0
Part Number:
RLS245 TE-11
Manufacturer:
ROHM/罗姆
Quantity:
20 000
RLN/RLS Class H Fuses
250/600 VAC
Littelfuse RLN/RLS series renewable fuses are a quality
product that have traditionally been used to provide low cost
protection of general purpose feeder and branch circuits
where available short-circuit currents do not exceed 10,000
amperes. However, generally increased levels of available
fault current and the distinct possibility that renewable fuses
may be improperly renewed, rendering them unsafe, have all
but eliminated the use of these fuses in new applications. In
addition, escalating labor costs and increasing automation,
which makes downtime very expensive, have greatly reduced
or eliminated the cost savings attributed to renewable fuses.
We recommend the use of POWR-PRO
Indicator
and FLNR series for 250 volt and below circuits. Complete
information on POWR-PRO
in the POWR-PRO
in this section of the catalog.
36
fuses for circuits between 250 and 600 volts
®
I
section of this catalog. FLNR fuses are
Renewable
®
Indicator fuses may be found
I
®
1 – 600 Amperes
IDSR series
SPECIFICATIONS
Voltage Ratings: AC: 250 Volts (RLN); 600 Volts (RLS)
Interrupting Ratings: AC: 10,000 amperes rms symmetrical
Ampere Range: 1 – 600 amperes
Approvals: Standard 248-6, Class H
FUSE LINKS: To order, specify LKN (250V) or LKS (600V)
plus ampere rating shown below.
AMPERE RATINGS
*These ampere ratings require two links per fuse.
**RLS Only.
COST CONSIDERATIONS
I
CAUTIONS
I
I
I
I
I
I
DIMENSIONS
I
Example part number (series & amperage): RLN 20
RECOMMENDED FUSE BLOCKS
Refer to Fuse Block section of this catalog for
additional information.
When comparing the cost of using renewable fuses with the
cost of other fuses, the labor required for replacing links
and the cost of additional downtime should be included.
Renewable fuses should only be used where short circuit
currents are known to be less than 10,000 amperes, and
where correct replacement of open links is assured.
After disassembly of fuse, examine carefully. Discard
any fuses which show evidence of weakened tube or
damaged components.
Remove all link residue from fuse tube.
Carefully clean all contact surfaces, and remove metal
spatter from all surfaces.
Install the proper rated fuse link and tighten all
connections securely.
Visually examine fuses for correct alignment of blades.
For dimensions, please refer to NLN series for RLN
dimensions and NLS series for RLS dimensions.
LH250 series (for RLN series fuses)
LH600 series (for RLS series fuses)
1
2
3
4
5
UL Listed (File No: E81895)
CSA Certified (File No: LR29862)
6
8
10
12 **
15
20
25
30
35
40
45
50
60
70
80
90
100
110
125
150
175
200
225 *
250 *
300 *
350 *
400 *
450 *
500 *
600 *