RF341-12 TELEDYNE [Teledyne Technologies Incorporated], RF341-12 Datasheet - Page 3

no-image

RF341-12

Manufacturer Part Number
RF341-12
Description
ULTRAMINIATURE MAGNETIC LATCHING TO-5 RELAYS SPDT DC TO C BAND
Manufacturer
TELEDYNE [Teledyne Technologies Incorporated]
Datasheet
SERIES RF341
GENERAL ELECTRICAL SPECIFICATIONS (@ 25° C) (Notes 2 & 3)
DETAILED ELECTRICAL SPECIFICATION (@ 25 °C) (Note 2)
Contact arrangement
Rated duty
Contact resistance
Contact load rating (DC)
Contact life rating
Coil operating power
(@nominal rated voltage)
Operate time
Minimum operate pulse
Intercontact Capacitance
Insulation resistance
Dielectric strength
BASE PART NUMBER
Coil resistance (ohms ±20%)
Set & reset voltage (VDC max)
Notes
1. Relays will exhibit no contact chatter in excess of 10 µs or transfer in excess of 1 µs.
2. Unless otherwise specified, parameters are intial values.
3. Characteristics shown as “typical” are based on available data and are best estimates. No on going verification tests are performed.
4. Pin positions 5 and 10 are recesses in the header for ground pin options (ground pins not shown).
5.To order ground pin options add Y (pin 5 position) or Z(pin 10 position) to the part base part number. Ex. RF341Y-5
6. Contact Teledyne Relays for Hi-Rel Screening/Program options.
Coil voltage (VDC)
OUTLINE DIMENSIONS AND SCHEMATIC DIAGRAM
DIA. MAX.
DIA. MAX.
(9.40)
(8.51)
.370
.335
.75 (19.05) MIN.
.280 (7.11) MAX.
External Dimensions
(
.017
.43
+.002
-.001
+.05
-.03
)
5 volt
12 volt
26.5 volt
±.010 (.25)
.035 (.89)
.200 (5.08)
±.010 (.25)
dia.
1 Form C (SPDT)
Continuous
.15 ohms max. initial. After life, .25 ohms (measured 1/8” from the header)
Low Level: 10 to 50 µA 10 to 50 mV
10,000,000 cycles (typical) at low level
410mW
288mW
351mW
2.0 ms. max. at nominal rated coil voltage
6.0 ms. max. at nominal voltage
0.4 pF typical
10,000 M min. between mutually isolated terminals
350 VRMS/60 Hz @ atmospheric pressure
Nom.
Max.
±.003 (.08)
.031 (.79)
36° ±3°
typ
RF341-5
5.0
6.0
3.5
61
TERMINAL LOCATION, PIN NUMBERING AND SCHEMATIC
SCHEMATIC IS SHOWN WITH COIL A LAST ENERGIZED
COIL A
TERMINAL NUMBERING
RF341-12
_
ARE VIEWED FROM THE TERMINALS
12.0
16.0
500
9.0
SCHEMATIC
7
8
+
6
9
10
5
1
4
2
TELEDYNE RELAYS
http:www//teledynerelays.com
+
RF341-26
Hawthorne CA 90250
12525 Daphne Ave.
_
(213) 777-0077
2,000
COIL B
26.5
32.0
18.0
© 1998

Related parts for RF341-12