f75387 Feature Integration Technology Inc., f75387 Datasheet - Page 26

no-image

f75387

Manufacturer Part Number
f75387
Description
?1o C Accuracy H/w Monitor Ic With Automatic Fan Speed Control
Manufacturer
Feature Integration Technology Inc.
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
f75387S
Manufacturer:
EMLSI
Quantity:
7 020
Part Number:
f75387SG
Manufacturer:
FINTEK
Quantity:
20 000
Power-on default [7:0] =0000_0000 b
Power-on default [7:0] =0000_0000 b
Bit
Bit
7
5
4
3
2
1
0
7
6
5
4
3
8.10. IRQ/SMI# ENABLE Register 2  Index 33h
8.11. Interrupt Status Register 2  Index 34h
3
2
1
0
6
EN_VCC_FAULT_SMI
EN_V3_FAULT_SMI
EN_V2_FAULT_SMI
EN_V1_FAULT_SMI
V3_FAULT_SMI_STS
VCC_EXC
EN_OVT2_SMI
OVT2_SMI_STS
V3_EXC
V2_EXC
V1_EXC
EN_OVT1_SMI
EN_OVT0_SMI
OVT1_SMI_STS
OVT0_SMI_STS
Reserved
Name
Reserved
Name
R/W
R/W
R/W
R/W
Attribute
Attribute
R/W
R/W
R/W
R/W
R/W
R/W
R/W
RO
R/W
R/W
R/W
R/W
RO
A one indicates VIN3 exceeds the high or low limit. A zero indicates VIN3 is
in the safe region.
A one indicates VIN2 exceeds the high or low limit. A zero indicates VIN2 is
in the safe region.
A one indicates VIN1 exceeds the high or low limit. A zero indicates VIN1 is
in the safe region.
A one indicates VCC exceeds the high or low limit. A zero indicates VCC is in
the safe region.
Enable temperature 1 OVT fault trigger SMI resister.
Enable temperature 0 (local temperature) OVT fault trigger SMI resister.
Return one when read.
Enable temperature 2 OVT fault trigger SMI resister.
Enable Voltage 3 fault trigger SMI resister.
Enable Voltage 2 fault trigger SMI resister.
Enable Voltage 1 fault trigger SMI resister.
Enable Voltage VCC fault trigger SMI resister.
A one indicates VT1 temperature sensor has exceeded high limit or
below the hysteresis limit. Write 1 to clear this bit, write 0 will be ignored.
A one indicates VT0 temperature sensor (local temperature) has
exceeded the high limit or below the hysteresis limit. Write 1 to clear this
bit, write 0 will be ignored.
Return 0 when read.
A one indicates VT2 temperature sensor has exceeded high limit or
below the hysteresis limit. Write 1 to clear this bit, write 0 will be ignored.
A one indicates VIN3 has exceeded the high or low limit continuously for
the times set by V_FAULT_QUEUE register. Write 1 to clear this bit,
write 0 will be ignored.
24
Description
Description
July, 2007
F75387
0.27P

Related parts for f75387