f75334 Feature Integration Technology Inc., f75334 Datasheet - Page 45

no-image

f75334

Manufacturer Part Number
f75334
Description
Performance Controller
Manufacturer
Feature Integration Technology Inc.
Datasheet
7-0 SEC3SPEED1
7-0 SEC4SPEED1
7-0 SEC5SPEED1
1-0 Fan1_temp_sel
Bit
Bit
Bit
Bit
8.2.43 FAN1 SEGMENT 3 SPEED COUNT
8.2.44 FAN1 SEGMENT 4 SPEED COUNT
8.2.45 FAN1 SEGMENT 5 SPEED COUNT
8.2.46 FAN1 Temperature Mapping Select
7
6
5
4
3
2
FAN1_INTERPOLATION_EN
FAN1_JUMP_HIGH_EN R/W
FAN1_JUMP_LOW_EN R/W
FAN1_PRE_UP_EN
FAN1_NO_STOP
FAN1_UP_T_EN
Name
Name
Name
Name
R/W
R/W Default
R/W
R/W Default
R/W Default
R/W
R/W Default
R/W
R/W
R/W
R/W
R/W
(70%)
(60%)
(50%)
B2h
99h
80h
0
0
0
0
1
1
1
Depend on the FAN1_MODE(CR96[1:0]) register setting:
2’b00: The value that set in this byte is the relative expect fan speed %
of the full speed in this temperature section.
2’b01: The value that set in this byte is mean the expect PWM
duty-cycle in this temperature section.
Depend on the FAN1_MODE(CR96[1:0]) register setting:
2’b00: The value that set in this byte is the relative expect fan speed %
of the full speed in this temperature section.
2’b01: The value that set in this byte is mean the expect PWM
duty-cycle in this temperature section.
Depend on the FAN1_MODE(CR96[1:0]) register setting:
2’b00: The value that set in this byte is the relative expect fan speed %
of the full speed in this temperature section.
2’b01: The value that set in this byte is mean the expect PWM
duty-cycle in this temperature section.
If this bit set to 1, when detect loading increase acutely, fan1 will pre-up
fan speed
If this bit set to 1, fan1 min duty will in duty that define in CR9C
Set 1 to force FAN1 to the highest speed if any temperature over its high
limit.
Set 1 will enable the interpolation of the fan expect table.
(Auto Linear Mode)
Set 1 that FAN1 speed will jump to FAN1 SEGMENT 1 SPEED when
temperature over T1 Boundary 1.
Set 0 that FAN1 speed will raise up to FAN1 SEGMENT 1 SPEED by slop
value( CR9B) when temperature over T1 Boundary 1.
Set 1 that FAN1 speed will jump to FAN1 SEGMENT 2 SPEED when
temperature under FAN1 Boundary Hystersis.
Set 0 that FAN1 speed will decrease to FAN1 SEGMENT 2 SPEED by
slop value( CR9B) when temperature under FAN1 Boundary Hystersis.
0: fan1 follow local temperature.
1: fan1 follow temperature 1.
2: fan1 follow temperature 2.
3: fan1 follow temperature 3.
– Index ACh
– Index ADh
– Index AEh
– Index AFh
38
Description
Description
Description
Description
F75334
July, 2007
V0.25P