hx50-psp2 LEM, hx50-psp2 Datasheet

no-image

hx50-psp2

Manufacturer Part Number
hx50-psp2
Description
Current Transducer 03~50-p/sp2
Manufacturer
LEM
Datasheet
Current Transducer HX 03 .. 50-P/SP2
For the electronic measurement of currents: DC, AC, pulsed, mixed,
with a galvanic isolation between the primary circuit (high power) and
the secondary circuit (electronic circuit).
Notes :
LEM Components
Primary nominal
r.m.s. current
V
R
R
V
I
V
V
X
V
V
V
TC
t
f
T
T
m
C
r
OUT
C
d
e
OE
OH
OT
A
S
OUT
L
L
I
10
15
20
25
50
PN
General data
Accuracy-Dynamic performance data
Electrical data
3
5
G
(A)
1)
2)
With R
Small signal only to avoid excessive heating of the magnetic core
Output voltage @ ± I
Output impedance
Load resistance
Supply voltage (± 5 %)
Current consumption
R.m.s. voltage for AC isolation test, 50/60Hz, 1 mn > 3
R.m.s. voltage for partial discharge extinction
at
Impulse withstand voltage, 1.2/50µs
Accuracy @ I
Linearity (0 .. ± I
Electrical offset voltage, T
Hysteresis offset voltage @ I
after an excursion of 3 x I
Thermal drift of V
Thermal drift of the gain (% of reading)
Response time @ 90% of I
Frequency bandwidth (-3 dB)
Ambient operating temperature
Ambient storage temperature
Mass
Min. internal creepage distance/clearance
Isolation material group
Standards
10pC
L
=2k
Primary current
measuring range
± 9
± 15
± 30
± 45
± 60
± 75
± 150
I
P
(A)
PN
, T
1)
PN
OE
A
)
= 25°C (without offset)
PN
, R
L
PN
A
= 2 k , T
= 25°C
P
P
2)
= 0;
Primary Conductor
Diameter x Turns
1.1d x 6T
1.4d x 4T
0.6d x 20T
0.8d x 12T
1.6d x 3T
1.6d x 2T
1.2 x 6.3 x 1T
(mm)
A
= 25°C
max. ± 1.5
I
- 25 .. + 85
- 25 .. + 85
8
EN50178
< ± 1
< ± 1
+2.5V±50
< ± 10
50
± 0.1
V
< 50
+12 .. +15
< 15
HX 03-P/SP2
HX 05-P/SP2
HX 10-P/SP2
HX 15-P/SP2
HX 20-P/SP2
HX 25-P/SP2
HX 50-P/SP2
5.5
OE
2
6
1
3
Type
±0.625
% of I
% of I
mV/K
%/K
kHz
mV
mV
mm
mA
µs
°C
°C
k
kV
kV
kV
g
V
V
PN
PN
Features
Advantages
Applications
I
PN
Galvanic isolation between primary
and secondary circuit
Hall effect measuring principle
Isolation voltage 3000V
Low power consumption
Extended measuring range(3x I
Single supply from +12V to +15V
Material according to UL94-V0
Low insertion losses
Easy to mount with automatic
handling system
Small size and space saving
Only one design for wide current
ratings range
High immunity to external
interference.
Switched Mode Power Supplies
(SMPS)
AC variable speed drives
Uninterruptible Power Supplies
(UPS)
Electrical appliances
Battery supplied applications
DC motor drives
=
3 .. 50 A
www.lem.com
030806/3
PN
)

Related parts for hx50-psp2

hx50-psp2 Summary of contents

Page 1

... Ambient storage temperature S m Mass Min. internal creepage distance/clearance Isolation material group Standards Notes : 1) With R = Small signal only to avoid excessive heating of the magnetic core LEM Components Primary Conductor Type Diameter x Turns (mm) 0.6d x 20T HX 03-P/SP2 0.8d x 12T HX 05-P/SP2 1. 10-P/SP2 1. 15-P/SP2 1. 20-P/SP2 1 ...

Page 2

50-P/SP2 (in mm) HX 03...25-P/SP2 19 Max. 10. OUT 10.85 Terminal Pin Identification 1.....0V 2.....0V 3.....+12V to +15V 4.....Output 5.....Primary input Current(+) 6.....Primary input Current(-) Specifications ...

Related keywords