DMS-30LCDA-4 MURATA-PS [Murata Power Solutions Inc.], DMS-30LCDA-4 Datasheet - Page 2

no-image

DMS-30LCDA-4

Manufacturer Part Number
DMS-30LCDA-4
Description
Loop-Powered, 1.8V Drop, 4-20mA Process Monitors with Full-Size LCD Displays
Manufacturer
MURATA-PS [Murata Power Solutions Inc.]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Company:
Part Number:
DMS-30LCDA-4/20B
Quantity:
180
Part Number:
DMS-30LCDA-4/20S-C
Manufacturer:
Murata Power Solutions Inc
Quantity:
135
➀ The DMS-30LCDA-4/20 can withstand continuous overcurrents, including those
➁ Because Murata Power Solution’s DMS Series loop-powered process monitors
➂ When looking up DIP-switch settings in the Tables and the desired display read-
Performance/Functional Specifications
Typical at T
Current Loop Input
Full Scale Input Range
Loop Burden
Voltage Drop
Overcurrent Protection
Performance
Sampling Rate
Accuracy (1 minute warm-up)
Temperature Drift
Display
Display Type and Size
Polarity Indication
Overrange Indication
Physical/Environmental
Operating Temperature
Storage Temperature
Humidity (non-condensing)
Case Material
Weight
Ordering Information
** Replaces obsolete DMS-30LCD-4/20S model
DMS-30LCDA-4/20S**
DMS-30LCDA-4/20B
DMS-30LCDA-4/20P
DMS-30LCDA-4/20I
DMS-BZL1
DMS-BZL2
DMS-30-CP
DMS-PS4-CM
DMS-PS7-CM
resulting from accidental reverse-polarity connections, up to ±40mA without
sustaining any damage.
employ active circuitry to convert the loop current into a voltage, their effective
series impedance (loop burden) varies in a manner that maintains the loop volt-
age drop relatively constant over the full 4-to-20mA current range. Listed burden
specification applies at 20mA.
ings can be achieved with either of two different settings, using the higher setting
number will usually result in less sensitive offset (R3) and span (R7) adjustments.
Please keep in mind that the DMS-30LCDA standard meter from which the DMS-
30LCDA-4/20 is derived has an accuracy specification of ±2 counts (max.). Thus,
it may not always be possible to obtain the exact desired display reading.
A panel-mount retaining clip is supplied with each model.
A
= +25°C, unless otherwise noted.
Unipolar reading, loop-powered LCD meter
Bipolar reading, loop-powered LCD meter
Positive reading, loop-powered LCD meter
Inverse reading, loop-powered LCD meter
Bezel assembly
Bezel assembly with sealing gasket
Panel cutout punch
+24V/0.45A ac/dc power supply module
+24V/0.7A ac/dc power supply module
Min.
+3.8
3½ digit, 0.4"/10.2mm reflective LCD
–20
0
0
"–1_ _ _ " for negative inputs
"1_ _ _" for positive inputs
"–" for negative readings
0.75 ounces (21 grams)
2.5 reading per second
±0.05%FS ±1 Count
±0.15
Typ.
1.8
Polycarbonate
80
www.murata-ps.com
Max.
+20.4
±0.3
100
±40
+60
+75
2.0
85
Cnts/°C
Units
Ohms
Volts
mA
mA
°C
°C
°C
Loop-Powered, 1.8V Drop, 4-20mA Process
OPERATING AND SETUP INSTRUCTIONS
DMS-30LCDA-4/20S (Standard Unipolar-Reading)
1. Set R7 (span/gain adjust) and R3 (zero/offset adjust) fully clockwise,
2. Configure the meter per DIP-switch setting #1 in Table 2.
3. Apply a precision 4mA input with proper polarity and adjust R3 until
Table 1. DMS-30LCDA-4/20S DIP Switch Settings for
Old Display Reading
1. 000 to 100-300
2. 000 to 400-600
3. 000 to 700-1999
4. ±100
5. ±200 to ±300
6. ±400 to ±600
7. ±700 to ±1900
The new DMS-30LCDA-4/20S unipolar-reading model has provisions
to accommodate all the display ranges of the obsolete DMS-30LCD-
4/20S. The “Old Display Readings” column in Table 1 is taken directly
from the DMS-30LCD-4/20S datasheet. Table 1 is provided as a guide
for determining equivalent DMS-30LCDA-4/20S DIP-switch settings in
upgrading existing applications.
Applications that had the obsolete DMS-30LCD-4/20S setup for ‘bipolar’
operation should now use the new DMS-30LCDA-4/20S model con-
figured per Table 1. Bipolar applications are those where a 4mA input
displays a negative number, a 12mA input displays “000”, and a 20mA
input displays a positive number (for example, “-100”, “000” and “100”).
Applications that had the obsolete DMS-30LCD-4/20S setup for ‘unipo-
lar’ operation should now use the new DMS-30LCDA-4/20S configured
per Table 2. Unipolar applications are those where a 4mA input displays
“000” and a 20mA input displays a higher positive number.
Important Instructions for Users of Obsolete
DMS-30LCD-4/20S Meters
The DMS-30LCDA-4/20S’s span and offset circuitry are optimized to
display standard, unipolar readings where a 4mA input always reads
“000” and a 20mA input always displays a higher positive number.
As shipped, the DMS-30LCDA-4/20S is calibrated to read “000” for a
4mA input and “1800” for a 20mA input. These readings are used for
factory test-purposes only. The following worst-case calibration pro-
cedure assumes the DMS-30LCDA-4/20S is completely misadjusted,
i.e., both potentiometers and the DIP switches are randomly set.
The next example below, while specifically tailored for the “000” and
“1800” readings just noted, can also be used as a guide when con-
figuring the DMS-30LCDA-4/20S for other unipolar display readings.
When performing DIP-switch settings, be sure the DIP-switch’s small
actuators are firmly engaged in their fully ON or fully OFF positions.
roughly 22 turns, and place SW1-SW8 to OFF.
the meter’s display reads “000”.
4mA
DMS-30LCDA-4/20 Series
Monitors with Full-Size LCD Displays
20mA
DMS-30LCD-4/20S Applications
Technical enquiries email: sales@murata-ps.com, tel:
SW1
New DMS-30LCDA-4/20S DIP Switch Setting
On
Off
On
Off
MPM_DMS30-LCDA.B02 Page 2 of 6
SW2
On
Off
Off
Off
Use Setting in Table 2
Use Setting in Table 2
Use Setting in Table 2
SW3
On
On
Off
Off
+1 508 339 3000
SW4
On
Off
Off
Off
SW5
Off
Off
Off
On

Related parts for DMS-30LCDA-4