MIC2012 MICREL [Micrel Semiconductor], MIC2012 Datasheet

no-image

MIC2012

Manufacturer Part Number
MIC2012
Description
USB Power Controller Advance Information
Manufacturer
MICREL [Micrel Semiconductor]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MIC2012
Manufacturer:
MICREL
Quantity:
50
Part Number:
MIC2012-1PZQS
Manufacturer:
MICREL
Quantity:
3 493
Part Number:
MIC2012-1R2K
Quantity:
4 150
Part Number:
MIC2012BM
Manufacturer:
MICREL
Quantity:
13 500
Part Number:
MIC2012CM
Manufacturer:
MICREL
Quantity:
63
Part Number:
MIC2012CM
Manufacturer:
MICREL/麦瑞
Quantity:
20 000
Company:
Part Number:
MIC2012CM
Quantity:
1 038
Part Number:
MIC2012CMTR
Manufacturer:
MIC
Quantity:
20 000
Part Number:
MIC2012PCM
Manufacturer:
MICREL/麦瑞
Quantity:
20 000
Part Number:
MIC2012YM
Manufacturer:
MICREL/麦瑞
Quantity:
20 000
General Description
The MIC2012 is a dual channel USB power switch designed
to support the power distribution requirements for USB Wakeup
from the ACPI S3 state. The MIC2012 will directly switch its
two outputs between a 5V main supply and a 5V auxiliary
supply normally provided in ATX style power supplies.
The MIC2012 will adjust its current-limit threshold according
to the ACPI state it is in. In the normal active S0 state the
current-limit is set at 500mA minimum per channel satisfying
the USB continuous output current specification. In the S3
state the current-limit can be reduced to only 100mA per
channel to minimize the current that is supplied by the
auxiliary supply thereby ensuring that voltage regulation is
maintained even during fault conditions.
The MIC2012 provides make-before-break switching to en-
sure glitch-free transitions between the S3 and S0 states.
Each channel is also thermally isolated from the other so that
a fault in one channel does not effect the other. FAULT status
output signals are also provided indicating overcurrent and
thermal shutdown conditions.
The MIC2072 option latches the output off upon detecting an
overcurrent condition for more than 5ms minimum. The
output can be reset by either toggling the EN inputs of the
MIC2072-1, -2 or by removing the load. Latching the output
off provides a circuit breaker mode of operation which re-
duces power consumption during fault conditions.
Typical Application
September 2000
MIC2012
Micrel, Inc. • 1849 Fortune Drive • San Jose, CA 95131 • USA • tel + 1 (408) 944-0800 • fax + 1 (408) 944-0970 • http://www.micrel.com
82801AA or Equivalent
ATX Power Supply
5V STANDBY
5V MAIN
SLP S3#
SLP S5#
OC0
OC1
Overcurrent Port 1
Overcurrent Port 1
S3 Control
Figure 1. USB Wakeup with Control Input
MAIN
AUX
S3#
FAULT1#
FAULT2#
MIC2012P
GND
OUT2
OUT1
1
Features
• Compliant to USB power distribution specifications
• Two completely independent switches
• Integrated switching matrix supports ACPI S0/S3 state
• Make-before-break switching ensures glitch-free
• No back-feed of auxiliary supply onto main supply
• Bi-level current-limit preserves auxiliary supply voltage
• Thermally isolated channels
• Thermal shutdown protection
• Fault status outputs with filter prevents false assertions
• Latched thermal shutdown options with auto-reset
• Undervoltage lockout
Applications
• Desktop PCs
• Notebook PCs
• Notebook Docking stations
• LAN Servers
• PC Motherboards
transitions without external FET circuits
transitions
during standby mode
regulation in standby mode
during hot-plug events
(MIC2072)
100 F
MIC2012/MIC2072
100 F
USB Power Controller
Advance Information
GND
GND
V
V
BUS
D+
BUS
D–
D+
D–
Downstream
Downstream
Port 1
Port 2
USB
USB
MIC2012/2072
Micrel

Related parts for MIC2012

MIC2012 Summary of contents

Page 1

... The MIC2012 is a dual channel USB power switch designed to support the power distribution requirements for USB Wakeup from the ACPI S3 state. The MIC2012 will directly switch its two outputs between a 5V main supply and a 5V auxiliary supply normally provided in ATX style power supplies. ...

Page 2

... MIC2012 Ordering Information Part Number Enable MIC2012CM n/a MIC2012PCM* n/a MIC2012-1CQS* Active High MIC2012-1PCQS* Active High MIC2012-2CQS* Active Low MIC2012-2PCQS* Active Low MIC2072CM* n/a MIC2072PCM* n/a MIC2072-1CQS* Active High MIC2072-1PCQS* Active High MIC2072-2CQS Active Low MIC2072-2PCQS* Active Low * Contact factory for availability. Pin Configuration FAULT1 ...

Page 3

... MAIN 5V Main Supply (Input): All MAIN inputs must be connected together externally. OUT1 Channel 1 (Output): For MIC2012-1, -2 both pins must be externally connected together. EN2 Enable (Input): Channel 2, active-high (–1) or active-low (–2). Toggling this input also resets the latched output of the MIC2072. ...

Page 4

... EN2, for MIC20x2-x only) I S3#, EN1, EN2 Input Current IN (EN1, EN2, for MIC20x2-x only) I OUT1, OUT2 Leakage Current OFF (MIC2012-x, MIC2072-x only) Pull-Up Current During Latched Output State (MIC2072-1, -2) MIC2012/2072 Operating Ratings (Note 1, Note 4) Supply Voltage (V Ambient Temperature (T Junction Temperature (T ...

Page 5

... For MIC20x2-2(P) OFF occurs when Micrel Min Typ Max Units 1. V/s 140 C 120 C 160 C 150 C 0 0.6 ms 120 s 0.5 ms 115 7.5 ms > 2.4V and 40ms max if one channel DLY MIC2012/2072 ...

Page 6

... MIC2012 Test Circuit V OUT MIC2012/2072 V OUT I Device OUT Under OUT Test 90% 90% 10% 10% 6 Micrel t f September 2000 ...

Page 7

... Timing Diagrams OUT OUT V OUT I OUT FAULT# MAIN S3# 1.5V September 2000 50% t OFF t ON 90% Figure 2. MIC2012/72-1 50% t OFF t ON 90% Figure 3. MIC2012/72-2 Output shorted to ground I LIMIT DLY Figure 4. Overcurrent Response Timing t H Figure 5. MAIN to S3# Timing 7 10% 10 1.5V MIC2012/2072 Micrel ...

Page 8

... MOSFET switch from the AUX input to each of its two outputs. Conversely when the S3# input is HIGH (S0 state) the MIC2012/72 will switch a 100m , 500mA MOSFET switch from the MAIN input to each of its two outputs. The lower current limit during the ACPI S3 state helps to ensure that the standby supply maintains regulation even during fault conditions ...

Page 9

... This helps to ensure that the power supply DLY voltage regulation is preserved and also prevents possible damage to sensitive components. Thermal Shutdown Figure 6. MIC2012 System Timing Load Removed– Figure 7. MIC2072 System Timing— Output Resets When Load is Removed 9 Overcurrent Fault ...

Page 10

... This information is believed to be accurate and reliable, however no responsibility is assumed by Micrel for its use nor for any infringement of patents or other rights of third parties resulting from its use. No license is granted by implication or otherwise under any patent or patent right of Micrel Inc. MIC2012/2072 PIN 1 0.012 (0.30) ...

Related keywords