NIPXI-2570 NI [National Instruments Corporation], NIPXI-2570 Datasheet

no-image

NIPXI-2570

Manufacturer Part Number
NIPXI-2570
Description
40 independent SPDT relays/Latching relays/Fully software programmable
Manufacturer
NI [National Instruments Corporation]
Datasheet
Overview
The Na ti onal In s tru m ents PXI-2570 is a 40-ch a n n el , gen era l - p u rpo s e
switch module. Featuring independent SPDT (Form C) relays, the
NI PXI-2570 maximizes relay density in a single PXI slot. Each relay
contains a normally closed (NC), normally open (NO), and common
(COM) terminal and can handle up to 100 VDC/100 VAC or up to
1 A of current. With 40 channels per module, you can switch several
hundred ATE loads in a single PXI chassis or thousands of channels
in a multiple-chassis configuration.
Automatic Scanning
The PXI-2570 is able to maximize throughput in automated test
applications by the use of scanning. Scanning improves throughput
by downloading a list of up to 32,000 connections to the switch and
c ycling thro u gh the list using an event (tri gger) wi t h o ut any
interruption from the host processor. Scanning is most efficiently
accomplished by mating the PXI-2570 with an instrument, such as
the NI PXI-4070 6
each measurement.
NI PXI-2570
• 40 independent SPDT relays
• Maximum switch capacity
• Latching relays
• 32,000-step scan list for
• Fully software programmable
• 145 cycles/s
• Ti ght synch ron i z a ti on with instru m en t s
Up to 100 VDC, 100 VAC
Up to 1 A switching/1 A carry
deterministic scanning
through hardware triggers
High-Density General-Purpose SPDT Relays
1
2
-digit FlexDMM, which issues a trigger after
Operating Systems
• Windows 2000/NT/XP
Recommended Software
• LabVIEW
• LabWindows
• Measurement Studio
• NI Switch Executive
Other Compatible Software
• Visual Basic
• C/C++
Driver Software (included)
• NI-SWITCH
Compliance
• UL
• CE
/CVI
Software
All National Instruments PXI switch modules are shipped with
N I - S W I TC H , an IVI-compliant driver of fering com p l ete
functionality for all sw itch modules. For additional assistance in
con f i g u ri n g, progra m m i n g, and managing high er- ch a n n el - co u n t
switching systems, NI Switch Executive software offers an easy-to-
use, intelligent switch management and visual routing environment.
Ordering Information
NI PXI-2570 ..................................................................778572-70
Includes switch module, NI-SWITCH driver software.
Accessories
NI Switch Executive
BUY ONLINE!
Visit
Development System ............................................778546-01
Deployment Engine ..............................................778548-00
ni.com/info
and en ter pxi 2 5 7 0 .
N E W

Related parts for NIPXI-2570

NIPXI-2570 Summary of contents

Page 1

High-Density General-Purpose SPDT Relays NI PXI-2570 • 40 independent SPDT relays • Maximum switch capacity Up to 100 VDC, 100 VAC switching/1 A carry • Latching relays • 32,000-step scan list for deterministic scanning • Fully ...

Page 2

High-Density General-Purpose SPDT Relays Specifications Input Characteristics Maximum switching voltage Channel-to-ground..................................... 100 V, CAT I Channel-to-channel ................................... 100 V Maximum current (switching or carry, per channel) ............... 1 A Simultaneous channels at maximum current (55 ˚C)......................... 40 Maximum switching power ...

Page 3

NI Services and Support NI has the servi ces and su pport to meet eeds around the gl obe and thro u gh the life cycle – from ...

Related keywords